JA
MTD logo
公式取扱説明書

MTD BV3100

84 ページ·2.5 MB·ブロワー·PDF·EN
MTD BV3100
目次 35セクション BV3100 2-Cycle Mulching Blower Vacuum · INTRODUCTION · TABLE OF CONTENTS · IMPORTANT MANUAL · … 表示非表示
Page 1 of the MTD BV3100 user manual — BV3100 2-Cycle Mulching Blower Vacuum
1ページ · クリックして拡大
1ページ

BV3100 2-Cycle Mulching Blower Vacuum

MTD BV3100 — BV3100 2-Cycle Mulching Blower Vacuum diagram (page 1)
図 1 · BV3100 2-Cycle Mulching Blower Vacuum
MTD BV3100 — BV3100 2-Cycle Mulching Blower Vacuum diagram (page 1)
図 2 · BV3100 2-Cycle Mulching Blower Vacuum
  • OPERATOR’S MANUAL . . . . . . . . . . . . GB2
  • MANUEL D’UTILISATION . . . . . . . . . . . . . F1
  • BENUTZERHANDBUCH . . . . . . . . . . . . . D1
  • MANUALE D’ISTRUZIONI PER L'USO . . . I1
  • MANUAL DE UTILIZAÇÃO . . . . . . . . . . . P1
  • MANUAL DE INSTRUCCIONES . . . . . . . . E1
Page 3 of the MTD BV3100 user manual — SAVE THESE INSTRUCTIONS
3ページ · クリックして拡大
3ページ

RULES FOR SAFE OPERATION

  • IMPORTANT SAFETY INFORMATION

READ ALL INSTRUCTIONS BEFORE OPERATING

  • Do not overreach. Always keep proper footing and balance.
  • Do not touch the engine or muffler. These parts get extremely hot from operation. When turned off they remain hot for a short time.
  • Read the instructions carefully. Be familiar with the controls and proper use of the unit.
  • Do not operate the unit with loose or damaged parts. Do not operate before repairing damage.
  • Inspect the unit before use. Replace damaged parts. Check for petrol leaks. Make sure all fasteners are in place and secure. Failure to do so can result in personal injury to the operator and bystanders, as well as damage to the unit
  • Use only genuine replacement parts when servicing this unit. These parts are available from your authorized service dealer. Do not use unaothorized parts, accessories or attachments for this unit. Doing so could lead to serious injury to the user, or damage to the unit, and void your warranty.
  • Be aware of the risk of injury to the head, hands and feet.
  • Clear the area of children, bystanders, and pets. At a minimum, keep all children, bystanders and pets outside a 15 meter (50 ft.) radius; there still may be a risk to bystanders from thrown objects. Bystanders should be encouraged to wear eye protection. If you are approached, stop the engine immediately.
  • Do not set unit on any surface except a clean, hard area while engine is running. Debris such as gravel, sand, dust, grass, etc. could be picked up by the air intake and thrown out by the discharge opening, damaging unit, property, or causing serious injury to bystanders or operator.

SAFETY WARNINGS FOR PETROL UNITS WARNING: Petrol (gasoline) is highly flammable, and its vapors can explode if ignited. Take the following precautions:

  • Keep hands, face, and feet at a distance from all moving parts. Do not touch or try to stop the impeller when it is rotating.
  • Store petrol only in containers specifically designed and approved for the storage of such materials.
  • Never use this unit for spreading chemicals, fertilizers, or other substances which may contain toxic materials.
  • Avoid creating a source of ignition for spilled petrol. Do not start the engine until petrol vapors dissipate.

WHILE OPERATING UNIT AS A BLOWER

  • Always stop the engine and allow it to cool before filling the petrol tank. Never remove the cap of the petrol tank, or add petrol, when the engine is hot. Never operate the unit without the petrol cap securely in place. Loosen the petrol tank cap slowly to relieve any pressure in the tank.
  • Never point the Blower in the direction of people or pets, or in the direction of windows. Always direct the blowing debris away from people, animals, glass, and solid objects such as trees, automobiles, walls, etc.

WHILE OPERATING UNIT AS A VACUUM

  • Remove the vacuum bag before refueling.
  • Avoid situations that could catch the vacuum bag on fire. Do not operate near an open flame. Do not vacuum warm ash from fireplaces, barbecue pits, brush piles, etc. Do not vacuum discarded cigars or cigarettes unless the cinders are completely cool.
  • Mix and add petrol in a clean, well-ventilated area outdoors where there are no sparks or flames. Slowly remove the petrol cap only after stopping engine. Do not smoke while fueling or mixing petrol. Wipe up any spilled petrol from the unit immediately.
  • The unit is designed to pick up dry material such as leaves, grass, small twigs and bits of paper. Do not attempt to vacuum wet debris and/or standing water, as this may result in damage to the Blower/ Vacuum. To avoid severe damage to the impeller, do not vacuum metal, broken glass, etc.

WHILE OPERATING

  • Never start or run the unit inside a closed room or building. Breathing exhaust fumes can kill. Operate this unit only in a well ventilated area outdoors.

OTHER SAFETY WARNINGS

  • Wear safety glasses or goggles and ear/hearing protection when operating this unit. Wear a face or dustmask if the operation is dusty. Long sleeve shirts are recommended.
  • Allow the engine to cool before storing or transporting. Be sure to secure the unit while transporting.
  • Never run the unit without the the proper equipment attached. When using this unit, always install the blower/vacuum tube, vacuum bag and make sure the vacuum bag is completely zipped closed.
  • Store the unit in a dry area, locked up or up high, to prevent unauthorized use or damage. Keep out of the reach of children.
  • Never douse or squirt the unit with water or any other liquid. Keep handles dry, clean and free from debris. Clean after each use, see Cleaning and Storage instructions.
  • Stop and switch the engine to off for maintenance, repair, to install or remove the blower/vacuum tubes or vacuum bag. The unit must be stopped and the impeller no longer turning to avoid contact with the rotating blades.

SAVE THESE INSTRUCTIONS

  • Avoid accidental starting. Be in the starting position whenever pulling the starter rope. The operator and unit must be in a stable position while starting. See Starting/Stopping Instructions.
Page 4 of the MTD BV3100 user manual — ON / START / RUN
4ページ · クリックして拡大
4ページ

RULES FOR SAFE OPERATION

SAFETY AND INTERNATIONAL SYMBOLS This operator's manual describes safety and international symbols and pictographs that may appear on this product. Read the operator's manual for complete safety, assembly, operating and maintenance and repair information.

SYMBOL MEANING • SAFETY ALERT SYMBOL

SYMBOL MEANING • IGNITION SWITCH

Indicates danger, warning, or caution. May be used in conjunction with other symbols or pictographs.

ON / START / RUN

  • WARNING - READ OPERATOR'S MANUAL
  • IGNITION SWITCH

Read the Operator’s Manual(s) and follow all warnings and safety instructions. Failure to do so can result in serious injury to the operator and/or bystanders.

  • HOT SURFACE WARNING
  • WEAR EYE AND HEARING PROTECTION WARNING: Thrown objects and loud noise can cause severe eye injury and hearing loss. Wear eye protection meeting ANSI Z87.1-1989 standards and ear protection when operating this unit. Use a full face shield when needed.

Do not touch a hot muffler or cylinder. You may get burned. These parts get extremely hot from operation. When turned off they remain hot for a short time.

  • CHOKE CONTROL A
  • FULL choke position. B
  • PARTIAL choke position. C
  • RUN position.
  • KEEP BYSTANDERS AWAY WARNING: Keep all bystanders, especially children and pets, at least 15 meters (50 ft.) from the operating area.
  • BLOWERS AND BLOWER/VACUUMS – ROTATING IMPELLER BLADES CAN CAUSE SEVERE INJURY WARNING: Stop the engine and allow the impeller to stop before installing or changing tubes or bag, or before cleaning or performing any maintenance.
  • PRIMER

Push primer bulb, fully and slowly, 10 times.

  • UNLEADED PETROL
  • BLOWER/VACUUM MODE CHANGE-OVER LEVER

Always use clean, fresh unleaded petrol.

A - Vacuum mode B - Blower mode

  • THROTTLE CONTROL
  • OIL

Indicates “HIGH” or “FASTEST” speed.

Refer to operator's manual for the proper type of oil.

  • THROWN OBJECTS CAN CAUSE SEVERE INJURY WARNING: Keep clear of blower outlet. Never point the blower at yourself or others. Objects can be thrown from blower. Do not operate unit without proper attachments and guards in place.
  • THROTTLE CONTROL

Indicates “IDLE,” “LOW” or “SLOWEST” speed.

OFF or STOP

Page 5 of the MTD BV3100 user manual — ATTACHING AND REMOVING THE BLOWER/ VACUUM TUBE
5ページ · クリックして拡大
5ページ
MTD BV3100 — ATTACHING AND REMOVING THE BLOWER/ VACUUM TUBE diagram (page 5)
図 3

As a blower • Cleaning of yards, garages, driveways, porches, patios, around walls, fences, etc.

As a vacuum • Picking up leaves, light debris, etc.

ATTACHING AND REMOVING THE BLOWER/ VACUUM TUBE

3. Insert the 2 (two) 8-32 x 3/4” slotted T20 Torx screws into the right side of the motor housing and the 2 (two) nuts into the left side of the motor housing (Fig. 2).
Attaching NOTEThe blower/vacuum tube comes un assembled
4. Tighten the screws firmly. Do not over-tighten.

on this unit. Installation is required to provide safe and easy use for the operator.

5. Install the 2 (two) remaining self-tapping 8-16 x 3/4” slotted T20 Torx screws into the holes on either side of the housing (Fig. 2). Tighten until snug, do not over-tighten.
1. Remove the screws and nuts provided from the hardware pack.
2. Insert the blower/vacuum tube all the way into the opening on the motor housing until the holes in the tabs on the blower/vacuum tube align with the screw holes in the housing (Fig. 1).
Page 6 of the MTD BV3100 user manual — ATTACHING AND REMOVING THE BLOWER/ VACUUM TUBE
6ページ · クリックして拡大
6ページ
MTD BV3100 — ATTACHING AND REMOVING THE BLOWER/ VACUUM TUBE diagram (page 6)
図 4

Attaching 1. Attach the vacuum bag to the vacuum bag hook on the blower/vacuum tube (Fig. 3).

2. Slide the vacuum bag tube over the debris exhaust tube on the housing. Push the tube until the latching tabs on both sides click into place, securing the bag on the unit (Fig. 4).

Removing 1. Press the latching tabs on both sides of the vacuum bag tube and pull the vacuum bag from the unit (Fig. 5).

1. Remove the 2 (two) self-tapping screws from either side of the housing.
MTD BV3100 — ATTACHING AND REMOVING THE BLOWER/ VACUUM TUBE diagram (page 6)
図 5
2. Remove the 2 (two) screws and nuts holding the blower/vacuum tube on the housing (Fig. 1).
2. Detach the vacuum bag from the vacuum bag hook.
3. Remove the blower/vacuum tube from the motor housing.
MTD BV3100 — ATTACHING AND REMOVING THE BLOWER/ VACUUM TUBE diagram (page 6)
図 6

Screw and Nut

Page 7 of the MTD BV3100 user manual — OIL AND PETROL INFORMATION
7ページ · クリックして拡大
7ページ

ASSEMBLY INSTRUCTIONS

INSTALLING AND ADJUSTING THE SHOULDER HARNESS

5. Place the harness over your head and onto your shoulder (Fig. 8).
MTD BV3100 — INSTALLING AND ADJUSTING THE SHOULDER HARNESS diagram (page 7)
図 7

clipped to the support fitting) prior to starting unit.

1. Push the strap through the center of the buckle.
2. Pull the strap over the cross bar and down through the slot in the buckle (Fig. 6).
3. Fully extend the harness.
6. While standing in the operating position (Fig. 8) adjust length to fit the operator’s size.
  • Lengthen the harness by pulling down on the strap and lifting the buckle end up (Fig. 9).
  • Shorten the harness by pulling the strap back through the buckle while holding the buckle (Fig. 9).
4. Attach the metal clip of the shoulder harness to the support fitting on top of the handle (Fig. 7).

OIL AND PETROL INFORMATION

Old and/or improperly mixed petrol are usually the main reasons for the unit not running properly. Be sure to use fresh, clean petrol and follow the instructions carefully for the proper petrol/oil mixture. RECOMMENDED OIL TYPE Use a high quality oil formulated for use in 2-cycle, air-cooled engines. RECOMMENDED PETROL TYPE Always use clean, fresh, unleaded petrol (gasoline) that is less than 60 days old.

OIL AND PETROL MIXING INSTRUCTIONS Thoroughly mix 5 liters of unleaded petrol (gasoline) with 125 ml. of 2 cycle engine oil in a separate petrol can (40:1). Do not mix them directly in the engine petrol tank.

Clip · Support Fitting · Clip

Page 8 of the MTD BV3100 user manual — ASSEMBLY INSTRUCTIONS
8ページ · クリックして拡大
8ページ
MTD BV3100 — ASSEMBLY INSTRUCTIONS diagram (page 8)
図 8

STARTING INSTRUCTIONS 1. Mix petrol (gasoline) with oil. Fill petrol tank with petrol/oil mixture. See Oil and Petrol Mixing Instructions.

harness and adjust it, but don’t clip it to the support fitting.

the vacuum bag from filling up while starting the engine.

10. Allow the engine to warm up for 5 to 10 seconds. Place the choke lever in Position C (Fig. 11).

always in the ON (I) position (Fig. 10).

11. Stand in the operating position and clip the shoulder harness to the support fitting
2. Set the blower/vacuum mode change-over lever to the up position (Blower Mode). See Operating as a Blower.

choke lever in Position C. Move the throttle lever to the fast position ( ) (Fig 10). Pull the starter rope briskly. The engine should start with three (3) to eight (8) pulls.

3. Fully press and release primer bulb slowly 10 times. Petrol should be felt and visible in the bulb (Fig. 11). If petrol hasn’t entered the bulb, press until it does.
4. Place the choke lever in Position A (Fig. 11).
5. With the unit on the ground, move the throttle lever to the fast position ( ) (Fig. 10).

engine. Put the throttle lever in the fast position ( ) (Fig 10) and start unit with the choke lever in Position B (Fig. 11).

6. Pull starter rope briskly (Fig. 12). Continue pulling until the engine sounds as though it wants to run (normally 2 to 5 pulls).

STOPPING INSTRUCTIONS 1. Move the throttle lever to the idle position ( ) (Fig. 10). Allow the engine to cool down by idling.

7. Place the choke lever in Position B (Fig. 11).
2. Press and hold the ignition switch down in the STOP [ O ] position until the engine comes to a complete stop (Fig. 10).
8. Pull starter rope briskly 1 to 3 times to start the engine (Fig. 12).
9. If the engine does not start, repeat steps 3 through 6.
MTD BV3100 — ASSEMBLY INSTRUCTIONS diagram (page 8)
図 9
Page 9 of the MTD BV3100 user manual — OPERATING INSTRUCTIONS
9ページ · クリックして拡大
9ページ

OPERATING INSTRUCTIONS

HOLDING THE BLOWER/VACUUM Before operating the unit, stand in the operating position (Fig. 13). Check for the following: • Operator is wearing proper clothing, such as boots, safety glasses or goggles, ear/hearing protection, gloves, long pants and long sleeve shirt.

Most dry blowing operations are better suited to low speed than high, while high speed is better for moving heavier items like large debris or gravel. Use the blower for trees, shrubs, flower beds and hard to clean areas (Fig. 15). Use the blower around buildings and for other normal cleaning (Fig. 16).

Fig. 13 OPERATING TIPS • Be sure the vacuum bag is zipped closed before operating the unit.

  • Assure the unit is not directed at loose debris or persons before starting unit.
  • The unit is in good working condition. The tubes and guards are in place and secure.
  • Always hold the unit with both hands when operating. Keep a firm grip on both the front and rear handle or grips.
  • To reduce the risk of hearing loss associated with sound level(s), the use of hearing protection is required.
  • Watch out for children, pets, open windows, or freshly washed cars, and blow debris away.
  • After using blowers and other equipment, clean up . Dispose of debris in trash receptacles.

OPERATING AS A BLOWER 1. Start engine. See Starting/Stopping Instructions.

2. Set the blower/vacuum mode change-over lever to the up position (Blower Mode) (Fig. 14).

position.

3. Place the shoulder harness over your head and onto your shoulder and adjust properly, see Installing and Adjusting the Shoulder Harness . Hold the blower as shown in Figures. 15, 16, and 17. Sweep from side to side with the nozzle several inches above the ground or floor. Slowly advance, keeping the accumulated pile of debris in front of you.
Show 5 more labels / short text on this page
Vacuum · Mode · Change-over lever · Blower · Mode
Page 10 of the MTD BV3100 user manual — OPERATING INSTRUCTIONS
10ページ · クリックして拡大
10ページ
MTD BV3100 — OPERATING INSTRUCTIONS diagram (page 10)
図 10

Use the blower for walls, overhangs and screens (Fig. 17).

CLEARING A BLOCKED TUBE / IMPELLER 1. Put the Ignition Switch in the OFF position [O] (Fig. 10) and wait for the impeller to stop rotating.

Fig. 17 OPERATING AS A VACUUM 1. Start engine. See Starting/Stopping Instructions.

2. Disconnect the spark plug wire to prevent the unit from starting.
2. Set the blower/vacuum mode change-over lever to the down position (Vacuum Mode) (Fig. 19).
3. Remove the blower/vacuum tube and the vacuum bag.
4. Carefully remove material blocking the tube or impeller. Inspect the blades to assure no damage has occurred. Rotate the impeller blades by hand to assure the blockage is completely cleared.

position.

MTD BV3100 — OPERATING INSTRUCTIONS diagram (page 10)
図 11
5. Reinstall the vacuum bag and blower/vacuum tube.
6. Reconnect the spark plug wire.

EMPTYING THE VACUUM BAG 1. While pressing the latching tabs on both sides of the vacuum bag tube, pull the vacuum bag off the unit (Fig. 20).

2. Detach the vacuum bag from the vacuum bag hook.
MTD BV3100 — OPERATING INSTRUCTIONS diagram (page 10)
図 12
3. Place the shoulder harness over your head and onto your shoulder and adjust properly, see Installing and Adjusting the Shoulder Harness. Hold the vacuum, tilting the blower/vacuum tube slightly, and use a sweeping action to collect light debris (Fig. 19). Small leaves and twigs will flow into the vacuum bag and be mulched as they pass through the fan housing, allowing the vacuum bag to hold more debris.
3. Unzip the bag and empty the contents into a garbage bag or container.
4. Turn the bag inside out after initial emptying and vigorously shake out dust and debris.
5. Turn Right-side out, Zip the bag closed and reinstall vacuum bag.
Page 11 of the MTD BV3100 user manual — AIR FILTER MAINTENANCE
11ページ · クリックして拡大
11ページ

MAINTENANCE AND REPAIR INSTRUCTIONS

AIR FILTER MAINTENANCE

2. Insert the four (4) screws into the holes in the air filter/muffler cover (Fig. 21) and tighten. Use a flat blade or T-20 Torx bit screwdriver. Do not over tighten. Do not force.

Removing the Air Filter/Muffler Cover 1. Place the choke lever in Position B.

remove the air filter/muffler cover.

2. Remove the four (4) screws securing the air filter/muffler cover (Fig. 21). Use a flat blade or T-20 Torx bit screwdriver.
3. Pull the cover from the engine. Do not force.

Cleaning the Air Filter Clean and re-oil the air filter every 10 hours of operation. It is an important item to maintain. Not maintaining the air filter will VOID the warranty. 1. Remove the air filter/muffler cover. See Removing the Air filter/Muffler Cover.

2. Remove the air filter from behind the air filter/muffler cover (Fig. 22).
3. Wash the filter in detergent and water (Fig. 23). Rinse the filter thoroughly. Squeeze out excess water. Allow it to dry completely.
4. Apply enough clean oil to lightly coat the filter (Fig. 24).
5. Squeeze the filter to spread and remove excess oil (Fig. 25).
6. Replace the air filter in the air filter/muffler cover (Fig. 22).

filter/muffler cover assembly, will VOID the warranty.

Reinstalling the Air Filter/Muffler Cover 1. Place the air filter/muffler cover over the back of the carburetor and muffler.

install the air filter/muffler cover.

Air Filter · Choke Lever · Screws Screws

Page 12 of the MTD BV3100 user manual — CLEANING THE UNIT
12ページ · クリックして拡大
12ページ

MAINTENANCE AND REPAIR INSTRUCTIONS

REPLACING THE SPARK PLUG Use a Champion RDJ7Y spark plug (or equivalent). The correct air gap is 0.5 mm (0.020 in.). Remove the plug after every 25 hours of operation and check its condition. 1. Stop the engine and allow it to cool. Grasp the plug wire firmly and pull the cap from the spark plug.

4. Install a correctly gapped spark plug in the cylinder head. Tighten by turning the 5/8 in. socket clockwise until snug. If using a torque wrench, torque to;
  • 12.3-13.5 N
  • m (110-120 in.
  • lb.). Do not over tighten.
2. Clean dirt from around the spark plug. Remove the spark plug from the cylinder head by turning a 5/8 in. socket counterclockwise.

0.020 in. (0.5 mm.)

3. Replace cracked, fouled or dirty spark plug. Set the air gap at 0.5 mm (0.020 in.) using a feeler gauge (Fig. 26).

CLEANING AND STORAGE

CLEANING THE UNIT

LONG TERM STORAGE If the unit will be stored for an extended time, 1. Drain all petrol from the petrol tank into a container. Do not use petrol that has been stored for more than 60 days. Dispose of the old petrol in accordance to local regulations.

  • Use a small brush to clean off the outside of the unit and to keep the air vents free of obstructions.

CLEANING THE VACUUM BAG 1. Empty the bag after each use to avoid deterioration and obstructing air flow, which will reduce the performance of the vacuum.

2. Start the engine and allow it to run until it stalls. This ensures that all petrol has been drained from the carburettor.
2. Wearing eye protection and a dust mask, clean the bag as needed. Turn the bag inside out after initial emptying and vigorously shake out dust and debris.
3. Allow the engine to cool. Remove the spark plug and put 30 ml. (1 oz.) of high quality motor oil into the cylinder. Pull the starter rope slowly to distribute the oil. Reinstall the spark plug.
3. Wash the bag once a year or more often if needed:

a. Remove the vacuum bag.

b. Turn bag inside out.

from the cylinder before attempting to start the blower/vacuum after storage.

c. Hang up.

d. Hose down thoroughly.

4. Thoroughly clean the unit and inspect for any loose or damaged parts. Repair or replace damaged parts and tighten loose screws, nuts or bolts. The unit is ready for storage. TRANSPORTING

e. Hang to dry.

f. Turn bag right-side out and reinstall. STORAGE

  • Allow the engine to cool before storing.
  • Allow the engine to cool before transporting.
  • Store the unit locked up to prevent unauthorized use or damage.
  • Secure the unit while transporting.
  • Store the unit in a dry, well ventilated area.
  • Drain the petrol tank before transporting.
  • Store the unit out of the reach of children.
  • Tighten petrol cap before transporting.
Page 13 of the MTD BV3100 user manual — C A U S E A C T I O N
13ページ · クリックして拡大
13ページ

TROUBLESHOOTING

ENGINE WILL NOT START

C A U S E A C T I O N

Empty petrol tank Fill petrol tank

Primer bulb wasn't pressed enough Press primer bulb fully and slowly 10 times

Engine flooded Use starting procedure with choke lever in the RUN position

Old or improperly mixed petrol Drain petrol tank / Add fresh petrol mixture

Fouled spark plug Replace or clean the spark plug

ENGINE WILL NOT IDLE

C A U S E A C T I O N

Air filter is plugged Replace or clean the air filter

Old or improperly mixed petrol Drain petrol tank / Add fresh petrol mixture

Improper carburettor adjustment Take to an authorized service dealer for carburettor adjustment

ENGINE WILL NOT ACCELERATE

C A U S E A C T I O N

Old or improperly mixed petrol Drain petrol tank / Add fresh petrol mixture

Improper carburettor adjustment Take to an authorized service dealer for carburettor adjustment

ENGINE LACKS POWER OR STALLS WHEN UNDER LOAD

C A U S E A C T I O N

Old or improperly mixed petrol Drain petrol tank / Add fresh petrol mixture

Improper carburettor adjustment Take to an authorized service dealer for carburettor adjustment

UNIT WILL NOT BLOW OR VACUUM

C A U S E A C T I O N

Bag is full Empty Bag. See Empty the Vacuum Bag

Blocked tube Clear Blockage. See Clearing a Blocked tube/Impeller

Blocked impeller Clear Blockage. See Clearing a Blocked tube/Impeller

Damaged impeller Take unit to an authorized service dealer

Page 14 of the MTD BV3100 user manual — BLOWER / VACUUM
14ページ · クリックして拡大
14ページ

SPECIFICATIONS

ENGINE

Engine Type Air-Cooled, 2-Cycle Displacement 31 cm3 (1.9 cu. in.) Maximum Engine Performance in accordance with ISO 8893 75 kw (1 hp) Operating RPM (@ 300 rd) 7,100 - 8,700 rpm Idle Speed RPM (@ 300 rd) 3,600 - 4,800 rpm Ignition Type Electronic Ignition Switch Rocker Switch Spark Plug Gap 0.5 mm (0.020 in.) Lubrication Petrol/Oil Mixture Petrol/Oil Ratio 40:1 Carburettor Diaphragm, All-Position Starter Auto Rewind Muffler Baffled with Guard Throttle Manual Petrol Tank Capacity 385 ml (13 oz.)

BLOWER / VACUUM

Throttle Control Finger-Tip Lever Blower Velocity up to 257 kmh (160 mph) Blower Air Output up to 12.1 cmm (424 cfm) Mulching Ratio up to 10:1 Vacuum Bag Capacity 35.24 Liters (1.0 bushels) Shoulder Harness Single Quick-Snap Approximate Mass (no petrol, with blower/vacuum tube and empty vacuum bag) 6 kg (13.5 lb.)

Front Vibration Level (Idle)* 4.77 m/s2 Rear Vibration Level (Idle)* 5.85 m/s2 Front Vibration Level (Operating RPM)* 8.61 m/s2 Rear Vibration Level (Operating RPM)* 10.46 m/s2 Sound Pressure Level (Idle) † 76 LpeqdB(A) Sound Power Level (Idle) ‡ 96 LweqdB(A) Sound Pressure Level (Operating RPM) † 89 LpeqdB(A) Sound Power Level (Operating RPM) ‡ 109 LweqdB(A)

* Method for obtaining level per ISO 7916 † Method for obtaining level per EN 27917 ‡ Method for obtaining level per ISO 108847

MTD BV3100について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
MTD BV3100に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

MTD BV3100 取扱説明書(PDF)

84 ページ·2.5 MB·ブロワー·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…