ISI5634PCI/4/8 Quick S tart Guide.
Quick Start Guide Model ISI5634PCI/4/8 P/N 82092804, Revision E This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. All rights reserved. Copyright © 2003 by Multi-Tech Systems, Inc.
Contents Chapter 1—Introduction and Description ............................ 5 Introduction ........................................................................................... 6 ISI5634PCI Modems .............................................
T o format a floppy disk for SCO5: ............................................... 40 T o untar the driver file and copy files onto floppy disk: .............. 40 T o install driver from floppy disk ................................................. 42 MultiT ech Installation Scri pt .
Chapter 1—Introduction and Description.
6 ISI5634PCI/4/8 Quick Start Guide Introduction Welcome to the world of data communications. You have acquired one of the finest intelligent data and fax modems available today from one of Americas oldest and most respected modem manufacturersMulti- Tech Systems, Inc.
7 Chapter 1—Introduction and Description network typically is converted from digitial to analog only once before it reaches your modem. Upstream transmissions and transmissions between client modems are limited to 33.6K bps, as are upstream transmissions to non-V.
8 ISI5634PCI/4/8 Quick Start Guide The processor, along with 256K bytes of RAM, works to allocate resources dynamically to the most active port. The ISI then generates one interrupt for an entire block of information and transfers the block to the systems microprocessor.
9 Chapter 1—Introduction and Description Quick Start Guide (this printed manual) A full User Guide on CD-ROM An installation CD-ROM that includes drivers, auxiliary software, and documentation (readme files, the User Guide, etc.
10 ISI5634PCI/4/8 Quick Start Guide Technical Specifications Computer Requirements Pentium ® - based PC or compatible with PCI Bus Architecture One of these operating systems: Microsoft Windows 2000, NT v. 4.0; Windows 95, Windows 98 and Windows Me; Novell Netware versions 5.
Chapter 2—Hardware Installation.
12 ISI5634PCI/4/8 Quick Start Guide Introduction Included in this chapter are two sets of instructions for installing the Multi-Tech ISI5634PCI card in your PCI bus personal computer. The first set of instructions is for installing the ISI5634PCI card.
13 Chapter 2—Hardware Installation 4. To avoid damaging the ISI5634PCI card and your PC, make sure your computer and any peripheral equipment connected to it are turned off. The ISI5634PCI can be installed in any Pentium equivalent PCI bus computer.
14 ISI5634PCI/4/8 Quick Start Guide Installing the ISI5634PCI card WITH the auxiliary module: 1. The auxiliary module attaches to the ISI5634PCI card. If you already have this card installed, you must remove it from the PC to install the auxiliary module.
15 Chapter 2—Hardware Installation 7. Before installing the ISI5634PCI card, carefully line up the pin- out connectors of the ISI5634PCI card with the pin-out connectors of the auxiliary module. See figure below. 8. Press gently but firmly to seat the module onto the card.
16 ISI5634PCI/4/8 Quick Start Guide edge of the board with the screw-hole for attaching the card to the computer chassis. 13. Turn on the power to the computer. You now are ready to install your drivers. Note: The LINE jack is not interchangeable with the wall jack.
Chapter 3 — Driver Installation.
18 ISI5634PCI/4/8 Quick Start Guide Introduction The ISI5634PCI card ships with drivers for each of the following operating systems: Windows ® 2000, Windows NT, Windows 95, Windows 98, Windows Me, Novell Netware version 5.x, SCO Open Server 5, and Linux.
19 Chapter 3—Driver Installation - Windows 2000 3. Insert the ISI Family CD-ROM into the CD-ROM drive (if drivers have been downloaded from the MultiTech web site, they will typically be on diskette; in that case, insert diskette into floppy drive).
20 ISI5634PCI/4/8 Quick Start Guide A second sequence of installation wizard screens appears. This sequence of screens deals with the setting up of ISI ports.
21 Chapter 3—Driver Installation - Windows 2000 14. A completion screen will appear. It will indicate that the first MultiTech ISI Port has been set up successfully.
22 ISI5634PCI/4/8 Quick Start Guide Windows 2000: Installing Modems to COM Ports Pre-Requisite: Installation of Windows 2000 driver software must be completed before you can install the modems of the ISI5634PCI card. 1. Go to Start | Settings | Control Panel | Phone and Modem Options .
23 Chapter 3—Driver Installation - Windows 2000 11. Screens denoting the installation of modems to specific COM ports will appear for each modem installed.
24 ISI5634PCI/4/8 Quick Start Guide 13. The Phone and Modems Options screen ( Modems tab) will re- appear and display the modems that have just been assigned to COM ports.
25 Chapter 3—Driver Installation - Windows 2000 Windows 2000: Removing ISI5634PCI Driver 1. Go to Start | Settings | Control Panel . 2. Click on Add/Remove Hardware . Click Next . 3. Click on Uninstall/Unplug a device and click Next . 4. In the subsequent screen, click on Uninstall a device and click Next .
26 ISI5634PCI/4/8 Quick Start Guide Windows 2000: Installing ISI Management Software (server OSs only) If you are using a Windows 2000 Server operating system ("Server" or "Advanced Server"), you must decide whether you want to use the MultiTech ISI Management Software in conjunction with your ISI5634PCI card.
27 Chapter 3—Driver Installation - Windows NT Windows NT: Driver Installation The following procedure describes how to install the ISI5634PCI in a system operating Microsoft Windows NT 4.0 for use with Remote Access Service (RAS) server and other communications/fax server type applications.
28 ISI5634PCI/4/8 Quick Start Guide 5. The Select Network Adapter dialog box appears. Click Have Disk . 6. The Insert Disk dialog box appears. Type in or browse for the path (file directory location) of the Windows NT driver (for example, E:servcarddriverswinntsetup.
29 Chapter 3—Driver Installation - Windows NT 10. The ISI Cards dialog box appears again showing the port resource allocation that has just been made. To add additional ISI5634PCI cards, click Add and repeat step 9. After the last ISI card has been added, click Close in the ISI Cards dialog box.
30 ISI5634PCI/4/8 Quick Start Guide 5. Select ports for modem use. For the ISI5634PCI-4, you should have reserved four ports during driver installation. Highlight four ports in the list. For the ISI5634PCI-8, you should have reserved 8 ports during driver installation.
31 Chapter 3—Driver Installation - Windows NT Networking. Click Yes . 9. The Remote Access Setup dialog box appears. Click Add . 10. Each COM port appears in a separate Add RAS Device dialog box. To add the highlighted device, click OK . 11. The Remote Access Setup dialog box displays again.
32 ISI5634PCI/4/8 Quick Start Guide Windows NT: Removing ISI5634PCI Driver 1. Click Start , Settings , Control Panel , and then double-click Network . 2. The Network dialog box appears. Click the Adapters tab. 3. Select Multi-Tech 4, or 8-port ISI Card, and then click Remove .
33 Chapter 3—Driver Installation - Windows 95/98/Me Windows 95/98/Me: Driver Installation 1. Ensure that your ISI5634PCI card has been installed according to the Hardware Installation Procedures in Chapter 2. 2. Turn on the PC and start Windows 95/98/Me.
34 ISI5634PCI/4/8 Quick Start Guide 9. A completion screen appears. 10. When prompted to restart your computer, click Yes and click OK . 11. During the re-start process, Windows 95/98/Me will detect the ISI5634PCI card. The Add New Hardware Wizard screen will appear.
35 Chapter 3—Driver Installation - Windows 95/98/Me Windows 95/98/Me: Installing Modems to COM Ports 1. Click Start , Settings , Control Panel , and then double-click the Modems icon. In the General tab, click Add . 2. The Install New Modem dialog box will appear.
36 ISI5634PCI/4/8 Quick Start Guide For the ISI5634PCI-4, select four COM ports (COM6 through COM9 are shown in this example). For the ISI5634PCI-8, select eight COM ports.
37 Chapter 3—Driver Installation - Windows 95/98/Me Windows 95/98/Me: Removing ISI5634PCI Driver 1. Click Settings , Control Panel , and then double-click Add/ Remove Programs . 2. From the list box, select MultiTech ISI Driver Device . 3. Click Add/Remove and follow screen instructions.
38 ISI5634PCI/4/8 Quick Start Guide NetWare Driver Installation Multi-Tech Systems provides AIO drivers for the ISI5634PCI cards, so they can function with Novell compatible asynchronous applications (e.g., NetWare Connect). The AIO driver is simply an NLM (NetWare Loadable Module) that runs on the file server.
39 Chapter 3—Driver Installation - Novell To install the ISI card scripts, copy aiomdms.mdc to f:systemaiodirectory . Click Yes to overwrite the existing aiomdms.
40 ISI5634PCI/4/8 Quick Start Guide SCO Open Server 5 Driver Installation The ISI driver for SCO Open Server 5 is shipped on ISI Family CD-ROM (FAT file system) and can also be downloaded from the Multi-Tech web site. In both cases, the driver files are compressed (tarred).
41 Chapter 3—Driver Installation - SCO Open Server 5 # cp sco50x.tar /isi 3. Untar this file and put its contents into the temporary directory. # cd /isi # tar xvf sco50x.tar 4. Copy the untarred (inflated or non-compressed) files to a floppy disk # cd /isi/unifiedinstimg301 #scosh - Select Manager .
42 ISI5634PCI/4/8 Quick Start Guide To install driver from floppy disk (Users starting with the untarred SCO5 driver on a floppy disk can begin the installation here). 1. Run the custom utility. 2. Select Software . 3. Select Install New . 4. Highlight driver file from local host and select Continue .
43 Chapter 3—Driver Installation - SCO Open Server 5 MultiTech Installation Script The Multi-Tech Installation Script for SCO Open Server 5 systems requests information about how many boards you want to install, designations for communication ports and printer ports, and how many pseudo devices you want to create for Multi_View utility.
44 ISI5634PCI/4/8 Quick Start Guide specify 4 devices for each ISI5634PCI-4 card installed. For example, if the computer contains three ISI5634PCI-8 cards, you would enter 24 . 3. This text appears on the screen and relates to the /dev directory.
45 Chapter 3—Driver Installation - SCO Open Server 5 Device basename selected: _________________ b. After you select a device basename, you are prompted for a printer base name. This prefix identifies each port that supports a terminal with a printer attached to its auxiliary port (for transparent printing).
46 ISI5634PCI/4/8 Quick Start Guide OR Type init 6 and press ENTER . Driver installation for the ISI5634PCI card now is complete. Activating Ports in SCO Open Server 5 SCO Open Server 5 provides a device database that monitors the activity of serial ports through which users can log onto the host.
47 Chapter 3—Driver Installation - SCO Open Server 5 Note: Only one of the options (e.g., modem control or local terminal access) should be enabled for any port at one time.
48 ISI5634PCI/4/8 Quick Start Guide Linux Driver for ISI5634PCI-4/8 This is the standard installation procedure for Linux and is applicable to all Linux operating systems of the correct kernel level (2.0, 2.2, or 2.4). The next major section of this manual, RedHat Linux 6.
49 Chapter 3—Driver Installation - Linux 3. List the files on the CD-ROM and locate the directory for the kernel in use (2.0 or 2.2/2.4), using this command ls 4. Untar the appropriate Linux driver using this command: > tar vxf {filename} /tmp At this writing, the filename will be either L300_20X.
50 ISI5634PCI/4/8 Quick Start Guide LINUX: Driver installation and loading Execute the 'Install' script to build the driver and to copy the driver and firmware files to the required folder.
51 Chapter 3—Driver Installation - Linux LINUX: Setting the baud rate The 'stty' utility can be used to set the baud rate of a particular port. For example, to set the baud rate of the first port on the first card (ttyM1a) to 38400 bps, execute ' stty 38400 < /dev/ttyM1a '.
52 ISI5634PCI/4/8 Quick Start Guide For the ISI5634PCI-4, it uses the following: - /dev/ttyM1a TO /dev/ttyM1d for the first card - /dev/ttyM2a TO /dev/ttyM2d for the second card - /dev/ttyM3a TO /dev/.
53 Chapter 3—Driver Installation - Linux LINUX -- PPP setup: The 'PPP-HOWTO' (a document that is available as a part of the 'HOWTO' documentation on most of the distributions under /usr/doc/ HOWTO) explains in detail the procedure for configuring a Linux machine as a PPP server.
54 ISI5634PCI/4/8 Quick Start Guide Removing the ISI Driver (Linux) 1. T ype cd /usr/local . Press ENTER. 2. T ype rm -r ISICOM . Press ENTER. 3. This will remove driver for all ISI5634PCI cards in that Linux server . 4. Remove the isictl file by typing rm isictl in the /dev directory .
55 Chapter 3—Driver Installation - RedHat Linux RedHat Linux 6.2/7.0 RPM Drivers for ISI5634PCI-4/8 Server Cards This installation procedure applies only to RedHat Linux versions 6.
56 ISI5634PCI/4/8 Quick Start Guide For RPM version 6.2, issue the command ' mcopy a:isicom-1.1-3.src.rpm <destination folder> ' to copy the isicom-1.1-3.src.rpm ( or current driver name) file to the destination folder. For RPM version 7.
57 Chapter 3—Driver Installation - RedHat Linux - Run rpm -i /isi/isicom-1.1-3.src.rpm . - Run rpm -ba /usr/src/redhat/SPECS/isicom- smp.spec . - Run rpm -ihv /usr/src/redhat/RPMS/i386/isicom- 1.1-3.i386.rpm - Reboot the system, either using the command init 6 <ENTER> or your favorite method.
58 ISI5634PCI/4/8 Quick Start Guide LINUX-RPM: TTY Devices Created by the Drivers Device files corresponding to ports on the ISI card are created in the /dev folder. Use ttyMxy for normal ports. Normal ports ( ttyM ) are configured for dial-in connections.
59 Chapter 3—Driver Installation - RedHat Linux LINUX-RPM -- Dial-in configuration: To configure a particular port for dial-in, utilities like 'mgetty' need to be installed on the system.
60 ISI5634PCI/4/8 Quick Start Guide Comm Software Using AT Commands You must have communications software installed in your computer to use the Multi-Tech modems on the ISI5634PCI card. If you want to use communications software that is already installed, you should reconfigure it for your new modem.
61 Chapter 3—Driver Installation - Comm Software 5. Select the port where the modem is connected (normally starts at COM5). 6. Select your serial port speed and label it maximum speed , DTE bps , or baud rate . If you use data compression, set your serial port baud rate to four times the modems maximum transmission speed or faster.
62 ISI5634PCI/4/8 Quick Start Guide.
Chapter 4—W arranty , Service, and T ech Support.
64 ISI5634PCI/4/8 Quick Start Guide Limited Warranty Multi-Tech Systems, Inc. ( MTS ) warrants that its products will be free from defects in material or workmanship for a period of two years from the date of purchase, or if proof of purchase is not provided, two years from date of shipment.
65 Chapter 4—Warranty, Service, and Tech Support.
82092804.
デバイスMulti-Tech Systems 8の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Multi-Tech Systems 8をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMulti-Tech Systems 8の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Multi-Tech Systems 8の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Multi-Tech Systems 8で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Multi-Tech Systems 8を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMulti-Tech Systems 8の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Multi-Tech Systems 8に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMulti-Tech Systems 8デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。