INST ALLA TION INSTR UCTIONS FREEDOM F-64 CONTR OL P ANEL/COMMUNICA T OR © NAPCO 2006 W I1501A 9/06 R For use with the Freed om F-64TP W ireless Touchpad, F-64T PG Garage Door Touchpad, the F-64TPBR .
THIS MA NU A L INCLUDES FEA T URES WH ICH ARE ON LY A V A I LABLE IN THE FREEDOM F- 64 CONTR OL P ANEL FIR MW ARE VERSI ON 30 O R LATER. NAPCO Securit y S ystems, Inc.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 3 T ABLE OF CONTENTS INT RO DUCT ION ........ ............ .......... ............ ............. ......... ............. ............ ............ .......... ... .. .
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 4 INTRODUCTION GENER A L DESCRIPTION Napco's Freedo m F-64 is a state-of-the -art microcomputer -based burgla ry and resident ial fire ala rm contro l panel o f modular design.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 5 SPECIFICATIONS Freedom F-64 Control Panel O perating Temp erature: 0-49°C (32-120°F) Input Po wer: 16.5-18.0 VAC via CLASS 2 Plug-In 20VA, 40VA or 50VA Transformer Loop Voltage : 10-13Vdc Loop Current: 3mA withou t Zone Doubling, 2.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 6 ORDERING INFORMATION System Components F-64: Residentia l UL-Listed Burg and Fire Control Panel F-64PROG: 32-Cha.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 7 Smoke De tect ors, 4-W ire: 1. ESL 445AT, 445C, 445CT, 445CR, 445CRT 2. Hochiki Am erica SLG-12 with YBC-RL4-RA Base 3. System S ensor 2312/2 4T; 1412; 14 12TH; 2412 TH Subtract total smoke-detector alarm cu rrent from available standby current.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 8 INST ALLA TION MOUNTING Control Panel Choose a mounting location accessible to (a) a continuously -powered AC so.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 9 Wiring Wire Touchpad(s), zones, expansion z one m odules and output devices as sho wn on the Wir ing Diagram . Note t hat the Wi ring Diag ram contains im portan t inform at ion not available elsewhere in this manual.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 10 TESTING THE SYST EM After installation is completed, test the system as f ollows. 1. Call the central station to inform them of the test. 2. Initiate an alarm, preferably on a zone that activates a stead y siren , and verif y proper signalling.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 11 WIRING CONNECTIONS BATT ERY The RED (+) and BLACK (-) flying leads must be connected to a 12VDC 4-7 AH Recharg eable Batter y, to serve as backup power in the event of AC Power Failure.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 12 ADDI TI ONAL EZMs AVAI LABL E DEV I CES 1. KEYPADS: GEM-RP2AS & G EM-RP1CAe2 2. X-10 I N TERFACE: GEM-X10 3. WIRED ZO NE EXPAN DER: GEM-EZM816 4. WIREL ESS RECEI VERS: G EM-RECV8 , GEM-RECV16 & GEM-RECV96 5.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 13 The basic zone configuration for the F-64 Panel is 8 zones. Co nnect as show n above to terminals 13-24. Normally Closed (N .C.) devices m ay be wired in series or Normally Open (N.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 14 Two-wire smoke detectors can on ly be connected to zones 7 and 8.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 15 Mo del 36 8 C ord TELEPHON E LINES Connect the Mo del 368 Cord as follows: 26 (RED = Telco Ring), 27 (GREEN = Telco Tip), 28 (G RAY = Home Ring) and 29 (BRO W N = Home Tip).
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 16 K E Y P AD / T O U C H P AD M E S S AG E S The F-64 PROG Progr ammer an d Touchpads can di splay the be low messages. Note: See page 6 for a listing of t he keypad / Touchpad spec ific User Guides avail able.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 17 GLOSSAR Y The Freedom 64 cont rol panel is capable of utilizing a combined tota l of 7 keypads and/or Touc hpads, with a maximum of 4 Free- dom Touchp ads assigned to a ddresses 1-4.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 18 Al a r m O u t p ut s In UL instal lations, ( 1) see Time Selection for timeou t requirem ent s; (2) Fire zones must be programmed for Pulse Alarm Output, and the option "Cha nge Pulse Alarm t o Cadenced Ala rm" mus t be programm ed.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 19 Arm if not close d at end of w indow. W hen the star t time is reached, the displ ay w ill notify the occupants that an Auto-Arm w il l be initiat ed in the noti fication period length of tim e.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 20 lay or the "Pre-Al arm W arning", th en no report will be s ent and n o messages will be di splayed at t he keypad/ Touchpa d.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 21 Default Code of "4 56789". Press RESET to exit the EZ Program Mode. Access the address loc ation "Cold Start" (see the Programming Inst ructions W I1502), t hen press the U button.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 22 Day Zone (Open; Short); Alarm o n Day Zone; Disable Auto-Res et on Day Zone; Reset Day Zone wi th A rm/Disarm O.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 23 " ACTIVATE DIA LER TEST Y/N " is displa ye d and then pr ess YES to initiate the transm issio n of a Te st Tim er si gnal. Note: Test T ime r reporting codes and Report Test Time r on Telco1 or Tel c o 3 must be programm ed.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 24 E19 - Lug E19 is the Li sten in Lug. It is an in put and w hen it is forced low the panel w ill silen ce the key pad/Touchpad so under an d bell outpu ts so that the Veri-pho ne can li sten to a ctivity at the resid ence.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 25 Enable Te lephone Line Fa ult Test Enable Li ne Fa ult Test w ill cause the pane l to monito r the phone l ine. A fa ilure w ill di splay as " SYSTEM T ROUBLE /E-08 SERVICE " for Telco Li ne Fail .
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 26 displa y and pulsing s ounder. An open circ uit on the Fire Zone will iden tif y a trouble and cau se flash ing " SYSTEM TROUBLE/ E41-00 SERVICE " LCD display and pulsi ng sounde r after a 10-sec ond dela y.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 27 Keypad A rea Assignments see Touchpad/Key pad Area Assignme nts Keypad Ju mpers see keypad Installati on Instructions Keypad / To uchpa d Featur es The foll owing programmed s yste m features will activ ate only if they have als o been en abled at the k eypad.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 28 Number of Rings Be fore Pickup ( Answer on Ring) See Callback-Me thod Downloa d One-Butt on A rmin g See Easy Arming Opening R eport; Ope ning Report Onl y After Alarm R eport (Do not program for UL installat ions).
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 29 a Priorit y Zone must be c orrected b efore the pane l can be armed. A ny zone may be selec ted as a Priority Zone. A zone in troub le tha t is neither a Pri ority Z one nor an Auto-By pass Zone will cause an a larm on arm ing.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 30 is availabl e, it is incl uded in the Recent C losing tran smission.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 31 Smoke Detect ors; 2-Wir e Smoke Dete ctors; Wir eless Smoke L ow Batter y Resound Connect sm oke detectors a s show n in th e diagrams. The "Fire Pow er" (Termina l 25) is used to re set the smoke de tectors.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 32 System Tro ubles (Glo bal and Area); Wirel ess Low Batter y; Wire less Super visory System troubles may be programm ed to report to an y tele phone num ber and/or activate any output.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 33 Time S elect ion The foll owing times ar e programma ble: Time and Da te in Dealer Pr ogram M ode The To uchpad Time an d Date ma y be set in the Eas y Menu Driven Program Mode.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 34 If a programme d zone g oes int o alarm, t he Touchpa d/keypad s ounder will activa te and will remain activ ated unti l the RES ET button is pressed o r the syste m is disa rmed .
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 35 Zone Numb er on Pulse Alar m See Data Format s: Two-Digit For mat Zone Resp onse Ti me (750 mS required for UL .
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 36 ST ANDBY -B A TTER Y CAL CULA TION WORKSHEET Use the procedure given below to determine the required standby battery capacity in Ampere-Hours (AH).
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 37 WIRING LEGEND Should removal of the circuit board be necessary , use this wiring legend to re locate wire lead s to their proper terminals.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 38 CP-01 Quick Refere nce Chart--SI A False Alarm Redu ction Feature Descript ion Programming Address Location CP-01 FEATURES are enabled with one global select ion in th e panel.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 39 Duress Code . The panel will not allow duplicate User Codes to be programmed. Every user program code may now be selected as an Am bush Cod e for Area 1 or Ar ea 2 b y enteri ng a _ 5 in the A rea 1 Opt ions or A rea 2 Options resp ectivel y.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 40 Out of Box Panel Operation The following desc ribes the new panel factory defaults: The new SIA CP-01 c omplian.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 41 1. Auto Reset and Swinger Shutdown are removed f rom burg zones. 2. 1422-bit 6 "Chirp Output on Keyfob Arm/Disarm" is enabled. 3. 1424-bit 0 "Automatic Interior Bypass/Easy Exit" is enabled.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 42 FCC STATEMENT This equipment generates a nd uses radio-frequency energy an d, if not installed and used properl y, that is, in strict accordance w ith the manufacturer's instructions, may cause in terference to rad io and television re ception.
L NAPCO Security Systems Freedom F-64 Installation Instructions WI1501A 9/06 Page 43 FREEDOM F-64 WIRING DIA GRAM FREEDOM F-64 Wiring Diagram.
Freedom F-64 Installation Instructions L NAPCO Security Systems WI1501A 9/06 Page 44 NAPCO SECURITY SYSTEMS, INC. (NAPCO ) warrants its products to b e free from manufacturing defects in materials and w orkmanship fo r thirty-six months following the dat e of manufa cture.
デバイスNapco Security Technologies WI1501Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Napco Security Technologies WI1501Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNapco Security Technologies WI1501Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Napco Security Technologies WI1501Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Napco Security Technologies WI1501Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Napco Security Technologies WI1501Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNapco Security Technologies WI1501Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Napco Security Technologies WI1501Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNapco Security Technologies WI1501Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。