NapoleonメーカーSAVOY OS11の使用説明書/サービス説明書
ページ先へ移動 of 16
INSTALLE R : THESE INSTRUCTI ONS MUST BE CONV EYED TO AND REMAIN WI TH THE HOMEOWN ER. CERTIFIED IN CANADA T O CAN/CSA C22.2 NO. B140.3, B140.1, B140.0 AND IN TH E UNITED ST A TES CONFORMS TO UL Std 3.
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE INTRODUCTION WARNING • The stov e is an oil-fired sto ve . Do not bu rn wood or other materials in this stov e. • Adults and especially children should be aler ted to th e hazards of high surf a ce temperatures and sho uld sta y aw a y to av oid b urns or clothing ignition.
NAPOL EON oil stoves are manufactured under the strict Standard of the World Rec ognized ISO9001 Quality Assur a nce Certificate . NAPOLEON pr oducts are designed with superior components and mate rials, assembled by trained craft smen who take great pride in their work.
General information Nominal he a t output Oil co nsu mpti o n ** Ch imne y dra ft re qu ir ed Weight Flue ou t let ins ide diam eter ma x spe ed mi n spe ed ma x spe ed mi n spe ed 27, 300 B TU/ hr .25 US ga l/h r .073 US g al/h r .06 " w. c. .024 " w.
Location and clearances If the stove is to be installed on a combustible f l oor, it must b e installed on sheet metal or a t i le. The oil d rip tray, 72636 ( not supplied) is a suitab l e substitute fo r either of these two p a ds. Maintain these minimum c learances to combustibl es (fig.
INSTALLATION DO NOT INSTAL L IN A ROOM USED FOR SLEEPING. The st ove must be firmly bolted to the floor wit h 1/4 inch lag bolts (fig . 8, p. 8). Minimum clearances to combustib les are as shown in figure 2, page 5. VENTING The chimney must be installe d in accordance wi th the manufac turer’s instructi ons.
There are two types of chimn e y connectors : A single wall chimney co nnector may be used for top connection : This connector must be 316 grade 26 gauge stainless steel o r 1 mm vitreous enamelled steel and with a 5" (12 7 mm) diameter. Secure the connector joints with 3 sheet met al screws.
FINISHING Mounting flue collar and blanking plate The stove is supplied with a connection flue at top. The flue collar is reversible (2 scre w s) so that the smoke exit can be done at rear or on t he top (f ig ur e 1 2 and fig u re 1 3, pa g e 9 ).
3 1 4 2 6 5 3 1 1 2 5 3 4 6 7 8 Figure 12 Figure 13 Figure 14 Figure 12 - Top flue outlet Figure 13 - Rear flue outlet 1. Blanking plat e 2. Burner 3. Flue collar 4. Baffle 5 Reflect or 6 Optional m irrors Figure 14 - Operating devic es 1. Control k nob 2.
OPERATING INSTRUCTIONS Understanding your oil stove Furnace oil is f e d from t h e tank to the burner f l oor (A) where is it ignited by means of a f irestarter. The heat produ c ed by this flame brings the burner temperature to the required level to vaporize the fu el.
Shut down 1. T ur n the control knob to “0" setting. 2. Lift the saf ety lev er . 3. T ur n off the oil tank fuel supply valv e. The oil tank fuel sup ply valve should always be shut off when the oil stove is not in operation.
MAINTENANCE Seasonal maintenance WEEKLY - DESCALE Push and pull the de-scaling lever in and out as well a s turning slightly at the same time complet e ly two or three times. Pu s h in for normal burner operation s or before relighting. EVERY 3 TO 4 MONTHS - CL EAN BURNER Remov e a ll thr ee catalys er components (C, D, E, figur e 1 5, page 10).
REPLACEMEN TS Ordering replacement parts Contact your dealer or the factory for questio n s concerning prices and policies on replacement parts. Normally all p a rts can be ordered throu g h your Napoleon dea ler or distributor. Wh e n ordering replacement parts alwa y s give the followin g information : 1.
1 2 3 4 5 6 7 8 9 10 61 13 21 15 16 17 18 19 60 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 62 64 20 40 65 61 60 10 60 60 16 3 55 55 .
Notes Document n° 1043-1 ~ 15/01/2 002 15.
SYMPT OM PRO BLEM TEST SO LUT ION Flame s extingu ish during l ighting. Very cold chi mney. N o draft established - Leave door ajar u ntil fire has caught . - check air sup ply in the room Fire extinguishes once firestarter has burnt off. Fuel tank is empty - Fill tank Fuel valve is close d.
デバイスNapoleon SAVOY OS11の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Napoleon SAVOY OS11をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNapoleon SAVOY OS11の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Napoleon SAVOY OS11の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Napoleon SAVOY OS11で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Napoleon SAVOY OS11を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNapoleon SAVOY OS11の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Napoleon SAVOY OS11に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNapoleon SAVOY OS11デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。