FieldPoint TM cFP-20 xx Quick Start Guide What Y ou Need to Get Set Up • cFP-20 xx LabVIEW RT controller • Mounting hardware (DIN rail, panel- mount, or rack-mount accessory) • I/O module(s) •.
2 cFP-20xx Quick Start Guide ni.com Mounting the Backplane on a DIN Rail A. Fasten the DIN rail clip(s) to the cFP-BP- x using a number 2 Phillips screwdriver and the 8-32 × 5/16 in. countersink screws shipped with the clip(s). B. Insert one edge of the DIN rail into the deeper opening of the DIN rail clip.
Mounting the Backplane on a Panel A. Fasten the panel-mount plates to the back of the cFP-BP- x using a number 2 Phillips screwdriver and the 8-32 × 5/16 in. countersink screws shipped with the kit. B. Bolt or screw the panel-mount accessory to a panel.
Mounting the Backplane in a Standard 19-in. Rack A. Fasten the rack-mount bracket to the back of the cFP-BP- x using the captive screws on the bracket. B. Bolt the rack-mount accessory to a standard 19-in. rack. C. Connect the PE ground terminal on the cFP-BP- x to safety ground.
I I n n s s t t a a l l l l t t h h e e c c F F P P - - 2 2 0 0 x x x x C C o o n n t t r r o o l l l l e e r r o o n n t t h h e e B B a a c c k k p p l l a a n n e e A.
6 cFP-20xx Quick Start Guide ni.com I I n n s s t t a a l l l l I I / / O O M M o o d d u u l l e e s s o o n n t t h h e e B B a a c c k k p p l l a a n n e e A. Align the captive screws on the I/O module with the holes on the backplane. B. Press firmly to seat the I/O module on the backplane.
I I n n s s t t a a l l l l C C o o n n n n e e c c t t o o r r B B l l o o c c k k s s o o n n t t h h e e B B a a c c k k p p l l a a n n e e In order to connect I/O modules to input signals or to external loads, you need to install a cFP-CB- x connector block or other connectivity accessory for each I/O module on the backplane.
C C o o n n n n e e c c t t t t h h e e c c F F P P - - 2 2 0 0 x x x x t t o o Y Y o o u u r r N N e e t t w w o o r r k k Connect the cFP-20 xx controller to an Ethernet network using the RJ-45 Ethernet port on the controller .
C. Use a separate power supply for each module that needs external power . D. Refer to the operating instructions for the power requirements of each I/O module. If a module requires external power , connect a power supply to the V and C inputs on the connector block for that module.
I I n n s s t t a a l l l l S S o o f f t t w w a a r r e e o o n n t t h h e e H H o o s s t t P P C C A. Install the software packages you plan to use, such as LabVIEW , LabVIEW RT , Lookout, Measurement Studio, or LabWindows/CVI, before you install the FieldPoint software.
11 cFP-20xx Quick Start Guide © National Instruments Corporation C. Click the + + sign next to I I A A S S e e r r v v e e r r w w i i t t h h O O P P C C in the left pane to expand the view .
G. Enter values on the Network Settings tab of the System Configuration dialog box, shown in the figure at right. If your network does not have a gateway server or DNS server , you should set those parameters to 0.0.0.0. • I I P P A A d d d d r r e e s s s s —The unique, computer-readable address of a device on your network.
I. Enter an IP address for the T ime Server on the Servers tab of the System Configuration dialog box, shown in the figure at right. The time server is a networked computer that runs the National Instruments T ime Service installed by FieldPoint Explorer .
14 cFP-20xx Quick Start Guide ni.com F F i i n n d d i i n n g g a a n n d d C C o o n n f f i i g g u u r r i i n n g g D D e e v v i i c c e e s s a a n n d d C C h h a a n n n n e e l l s s After you have configured the cFP-20 xx in FieldPoint Explorer , follow these steps to configure Compact FieldPoint devices and channels.
C. T o configure the hardware settings of a particular I/O module, right-click the device name and select E E d d i i t t t t h h i i s s d d e e v v i i c c e e . The Device Configuration dialog box appears, as shown in the figure above. For output modules, you can choose settings for Watchdog Configuration.
16 cFP-20xx Quick Start Guide ni.com D. Click C C h h a a n n n n e e l l C C o o n n f f i i g g u u r r a a t t i i o o n n to access the Channel Configuration dialog box, shown in the figure at right. Make your selections in this dialog box as follows: 1.
17 cFP-20xx Quick Start Guide © National Instruments Corporation.
18 cFP-20xx Quick Start Guide ni.com S S a a v v i i n n g g H H a a r r d d w w a a r r e e C C o o n n f f i i g g u u r r a a t t i i o o n n a a s s P P o o w w e e r r - - U U p p S S t t a a t t.
ni.com Go to ni.com/support for the most current manuals, examples, and troubleshooting information. For telephone support in the United States, create your service request at ni.
デバイスNational Instruments CFP-20XXの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
National Instruments CFP-20XXをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNational Instruments CFP-20XXの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。National Instruments CFP-20XXの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。National Instruments CFP-20XXで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
National Instruments CFP-20XXを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNational Instruments CFP-20XXの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、National Instruments CFP-20XXに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNational Instruments CFP-20XXデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。