QUICK REFERENCE NI-DMM Instrument Driver Initialize and Close ICON TYPE P ARAMETER VALUE TO SET , COMMENTS 1 ViRsrc resourceName For T raditional NI-DAQ devices, use DAQ:: # , where # is the device number . For NI-DA Qmx devices, the device name is assigned by Measurement & Automation Explorer (MAX).
2 ni.com Initialize and Close (continued) ICON TYPE P ARAMETER VALUE TO SET , COMMENTS ViSession vi Session handle Configure ICON TYPE P ARAMETER VALUE TO SET , COMMENTS ViSession vi Session handle Vi.
Measurement Options (continued) ICON TYPE P ARAMETER VALUE TO SET , COMMENTS ViSession vi S ession handle ViInt32 AutoZero Default = Auto ViSession vi S ession handle ViInt32 ADC Calibration Default =.
4 ni.com Capacitance and Inductance ICON TYPE P ARAMETER VALUE TO SET , COMMENTS ViSession vi Session handle ViInt32 Cable Comp T ype ViSession vi Session handle ViReal64 Conductance ViReal64 Suscepta.
5 NI-DMM Instrument Driver Quick Reference T riggers ICON TYPE P ARAMETER VALUE TO SET , COMMENTS ViSession vi Session handle ViInt32 T rigger Source Default = Immediate ViReal64 T rigger Delay Defaul.
NI-DMM Instrument Driver Quick Reference 6 ni.com Actual V alues ICON TYPE P ARAMETER VALUE TO SET , COMMENTS ViSession vi Session handle ViReal64* autoR ange V alue Output ViSession vi Session handle.
Acquisition (continued) ICON TYPE P ARAMETER VALUE TO SET , COMMENTS ViSession vi Session handle ViInt32 Maximum Time Milliseconds ViInt32 Number to Read Default = 1 ViReal64[]* W aveform Data Output .
Low-Level Acquisition (continued) ICON TYPE P ARAMETER VALUE TO SET , COMMENTS ViSession vi Session handle ViInt32 Maximum Time Milliseconds ViInt32 Number to Fetc h Default = 1 ViReal64[ ]* W aveform.
Utility (continued) ICON TYPE P ARAMETER VALUE TO SET , COMMENTS ViInt32 Function DC volts, AC volts, and so on ViReal64 R ange Input ViReal64 R esolution Input ViReal64 Measurement Input ViChar [ ] Mode String Output ViChar [ ] Range String Output ViChar [ ] Data String Output ViSession vi Session handle ViReal64* Digits Output (3.
Calibration (continued) ICON TYPE P ARAMETER VALUE TO SET , COMMENTS ViSession vi S ession handle ViString Reserved " " ViReal64* T emperature Output ViSession vi Session handle ViInt32 Area.
© National Instruments Corporation 11 NI-DMM Instrument Driver Quick Reference © National Instruments Corporation Initialize Configure Hardware Read Close Session Initiate/Fetch DMM Programming Flow 322614f.
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the T erms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.
デバイスNational Instruments Instrument Driver NI-DMMの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
National Instruments Instrument Driver NI-DMMをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNational Instruments Instrument Driver NI-DMMの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。National Instruments Instrument Driver NI-DMMの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。National Instruments Instrument Driver NI-DMMで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
National Instruments Instrument Driver NI-DMMを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNational Instruments Instrument Driver NI-DMMの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、National Instruments Instrument Driver NI-DMMに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNational Instruments Instrument Driver NI-DMMデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。