OPERATING INSTRUCTIONS AND S PECIFICATIONS NI 9264 16-Channel, ± 10 V, 16-Bit Analog Voltage Outp ut Module ni.com/manuals Deutsch Français.
NI 9264 Operating I nstruction s and Specificati ons 2 ni.com This doc u ment describes ho w to u se the National Instr u ments 9 264 and incl u des specif ications and term inal assignments for the NI 9264. V isit ni.com/info and enter rd s oftwarever s ion to determine which software yo u need for the mod u les yo u are u sing.
© National Inst ruments Corp. 3 NI 9264 Operating Instructi ons and Specific ations Safety Guidelines Operate the NI 9264 only as described in these operating instr u ctions. Hot Surface This icon denotes that the component may be hot. T o u ching this component may res u lt in bodily inj u ry .
NI 9264 Operating I nstruction s and Specificati ons 4 ni.com Caution When mod u le terminals are hazardo u s voltage LIVE (>42.4 V pk /60 VDC), yo u m u st ens u re that devices and circ u its connected to the mod u le are properly ins u lated from h u man contact.
© National Inst ruments Corp. 5 NI 9264 Operating Instructi ons and Specific ations Ex nA IIC T4 hazardo u s locations; and nonhazardo u s locations only . Follo w these g u idelines if yo u are installing the NI 9264 in a potentially explosi ve environm e nt.
NI 9264 Operating I nstruction s and Specificati ons 6 ni.com Special Conditions for Hazard ous Locations Use in Europe This eq u ipment has been e val u ated as Ex nA IIC T4 eq u ipment u nder DEMK O Certificate No. 07 A TEX 0626664X. Each mod u le is marked II 3G and is s u itable for u se in Zone 2 hazardo u s locations.
© National Inst ruments Corp. 7 NI 9264 Operating Instructi ons and Specific ations Connecting the NI 9264 The NI 9264 has a 36-terminal detachable spring-te rminal connector that provides connections for 16 analog o u tp u t channels.
NI 9264 Operating I nstruction s and Specificati ons 8 ni.com Each channel of the NI 9264 has a terminal to which yo u can connect the positiv e lead of a load. Each cha nnel also has a common terminal, COM, and there are fo u r additional COM terminals at the bottom of the c onnector .
© National Inst ruments Corp. 9 NI 9264 Operating Instructi ons and Specific ations protection. Refer to Fig u re 4 for an ill u stration of the o u tp u t circ u itry for one channel of the NI 9264. Figure 4. Output Cir cuitr y for One Channel of the NI 9264 When the mod u le powers on, the channels o u tp u t the start u p voltage.
NI 9264 Operating I nstruction s and Specificati ons 10 ni.com Connecting Wires to the NI 9264 Connecto r Use a flathead scre wdriv er with a blade smaller than 2.3 × 1.0 mm (0.09 × 0.04 in.) to connect wires to the detachable spring-terminal connector .
© National Inst ruments Corp. 11 NI 9264 Operating Instructi ons and Specific ations Wiring for High-Vib ration Applications If an application is s u bject to high vibrat ion, National Instr u ments recommends that yo u u se the NI 9940 backshell kit to protect the connections.
NI 9264 Operating I nstruction s and Specificati ons 12 ni.com Specifications The follo wing specifications a re typical for the range – 40 to 70 °C u nless otherwise noted. All v oltages are relat iv e to COM u nless otherwise noted. Output Characteristics N u mber of channels .
© National Inst ruments Corp. 13 NI 9264 Operating Instructi ons and Specific ations Power -do wn voltage .................... ..... 0 V 1 O u tp u t impedanc e ... ............ ........... ... 2.0 Ω Acc u racy Stability Gain drift .. ............. .
NI 9264 Operating I nstruction s and Specificati ons 14 ni.com Protection Overv oltage ............. ........... ........ ±27 V a t 25 °C Short-circ u it .... ........... ......... ........ Indefinitely Update time Noise ............................
© National Inst ruments Corp. 15 NI 9264 Operating Instructi ons and Specific ations Capacitiv e dri ve ............. ........... ........ 1,500 pF max Monotonicity......... .................. .......... 16 bits DNL .... ............ ........ .......
NI 9264 Operating I nstruction s and Specificati ons 16 ni.com Physical Characteristics If yo u need to clean the mod u l e, wipe it with a dry to wel. Spring-terminal wiring..... ............ ..... 18 to 28 A WG copper cond u ctor wire with 7 mm (0.28 in.
© National Inst ruments Corp. 17 NI 9264 Operating Instructi ons and Specific ations Meas u rement Cate gory II is for meas u rements performed on circ u its directly connect ed to the electrical dist rib u t ion system.
NI 9264 Operating I nstruction s and Specificati ons 18 ni.com Hazardous Locations U.S. (UL) ... ........... ........... ............ ..... Class I, Division 2, Gro u ps A, B, C, D, T4; Class I, Zone 2, AEx nA IIC T4 Canada (C-UL) ....... ............
© National Inst ruments Corp. 19 NI 9264 Operating Instructi ons and Specific ations Operating h u midity (IEC 60068-2-56)....... ........... ............ 10 to 90% RH, noncondensing Storage h u midity (IEC 60068-2-56)....... ........... ............
NI 9264 Operating I nstruction s and Specificati ons 20 ni.com Electromagnetic Compatibility This prod u ct is designed to meet the req u ire ments of the follo wing standards of EMC for electrical eq.
© National Inst ruments Corp. 21 NI 9264 Operating Instructi ons and Specific ations Note Refer to the Declaration of Co nformity (DoC) for this prod u ct for any additional reg u latory compliance information. T o obtain the DoC for this prod u ct, visit ni.
NI 9264 Operating I nstruction s and Specificati ons 22 ni.com Waste Electrical and Electronic Equipment (WEEE) EU Customers At t he end of their lif e cycl e, all prod u cts must be sent to a WEEE re c ycling center . For more information abo u t WEEE recycling ce nters and National Instr u ments WEEE initiati ves, visit ni.
© National Inst ruments Corp. 23 NI 9264 Operating Instructi ons and Specific ations Where to Go for Support The National Instr u ments W eb site is yo u r comple te reso u rce for technical s u pport.
National Instruments, NI, n i.com, and LabVIEW are trademarks of National Instrument s Corporation. Refer to the Terms of Use section on ni.com/legal for more informati on about National Instruments t rademarks. Other product and company names ment ioned herein are tradema rks or trade names of their respec tive companies.
デバイスNational Instruments NI 9264の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
National Instruments NI 9264をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNational Instruments NI 9264の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。National Instruments NI 9264の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。National Instruments NI 9264で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
National Instruments NI 9264を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNational Instruments NI 9264の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、National Instruments NI 9264に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNational Instruments NI 9264デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。