PXI NI PXI-1056 User Manual NI PXI-1056 User Manual September 2005 371551A-01.
Support Worldwide Technical Support and Product Info rmation ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Aust in, Texas 78759-3504 USA Tel: 512 683 0100 Worldwide O.
Important Information Warranty The NI PXI-1056 is warranted agai nst defects in materials and workmanshi p for a period of on e year from the date of sh ipment, a s evidenced by receipts or other documentati on. National Instruments wil l, at its option, repair or replace equipment that proves to be defect ive during the warranty period.
© National Instruments Corpor ation v NI PXI-1056 User Manual Contents About This Manual Conventions ............ .............. .............. .............. .............. .............. ............... .............. .... v ii Related Documentation .
Contents NI PXI-1056 User Manual vi ni.com Remote Voltage, Temperature, and Fan Monito ring............. .............. .............. ............ 2-9 Serial Communication Command Set ............. .............. .............. .............. ...... 2-10 Terminal Settings .
© National Instruments Corporat ion vii NI PXI-1056 User Manual About This Manual The NI PXI-1056 User Manual contai ns information about installing , configuring, using, and maintaini ng the NI PXI-1056 18-slot chassis.
About This Manual NI PXI-1056 User Manual viii ni.com Related Documentation The following documents contain information that you mi ght find helpful as you read this manual: • CompactPCI Specification PICMG 2.0 R 3.0 • PXI Hardware Specificatio n , Revision 2.
© National Instruments Corporat ion 1-1 NI PXI-1056 User Manual 1 Getting Started This chapter describes the key featur es of the PXI-1056 chassis and lists the kit contents and optional equip ment you can order from National Instrume nts. Unpacking Carefully inspect the shipping contai ner and the chassis for damage.
Chapter 1 Getting Started NI PXI-1056 User Manual 1-2 ni.com If you are missing any of the items listed in Table 1-1, or if you have the incorrect AC power cable, co ntact National Instruments.
Chapter 1 Getting Started © National Instruments Corporat ion 1-3 NI PXI-1056 User Manual • T emperature-sensing module that can adju st fan speed based on air-intak e temperature to minimize audib.
Chapter 1 Getting Started NI PXI-1056 User Manual 1-4 ni.com Figure 1-2. Rear View of the PXI-1056 Chas sis Optional Equipment Contact National Instruments to ord er the following opti ons for the PXI-1056 chassi s. EMC Filler Panels Optional EMC filler panel kits are available fro m National Instruments.
Chapter 1 Getting Started © National Instruments Corporat ion 1-5 NI PXI-1056 User Manual PXI-1056 Backplane Over view Interoperability with CompactPCI The PXI-1056 backplan e is interoperab le with 5 V and universal PXI-compatible product s and standard CompactPCI products.
Chapter 1 Getting Started NI PXI-1056 User Manual 1-6 ni.com The star trigger slot can also be used to provide a PXI_CLK10 signal to the backplane. For more information regarding PXI_CLK10, refer to the System Reference Clock section. Peripheral Slots There are 17 3U-sized peripheral slots including the star trigg er slot.
Chapter 1 Getting Started © National Instruments Corporat ion 1-7 NI PXI-1056 User Manual Figure 1-3. PXI CLK_10 and Star T rigger Routing 3 4 5 6 7 8 9 10 11 12 14 15 13 17 18 16 Local Bus Local Bus.
Chapter 1 Getting Started NI PXI-1056 User Manual 1-8 ni.com Tr i g g e r B u s All slots on each PXI bus segment shar e eight PXI trigger lines. You can use these trigger lines in a variety of ways. For example, you can use triggers to synchronize the operation of severa l different PXI peripheral modules.
© National Instruments Corporat ion 2-1 NI PXI-1056 User Manual 2 Installation and Configuration This chapter describes how to install, confi gure, and use the PXI-1056 chassis. Before connecting the chassis to a power source, read this chapter and the Read Me First: Safety and Radio-Frequency Interference document included with your chassis.
Chapter 2 Installation and Configuration NI PXI-1056 User Manual 2-2 ni.com personnel operating th e chassis. Fu rthermore, damage o r fire may occur if replacement parts are unsuitable. • Modification —Do not modify any part of the chassis from its orig inal condition.
Chapter 2 Installation and Configur ation © National Instruments Corporat ion 2-3 NI PXI-1056 User Manual Figure 2-1. PXI-1056 Chassis Airflow Side View Install the chassis so that you ca n easily access the rear panel. This simplifies replacing the air filter or po wer supply shuttle, if necessary .
Chapter 2 Installation and Configuration NI PXI-1056 User Manual 2-4 ni.com Rack Mounting Rack-mount applications may require the option al rear rack mount kit available from National Instrume nts.
Chapter 2 Installation and Configur ation © National Instruments Corporat ion 2-5 NI PXI-1056 User Manual The po wer switch allows you to power on the chassis or place it in standby mode. Push the power switch to the On ( Left) position (if n ot already on).
Chapter 2 Installation and Configuration NI PXI-1056 User Manual 2-6 ni.com Figure 2-2. Injector/Ejector Handle Position during Controller or Peripheral Module Insertion 3. When you begin to feel resistance, push up on the injector/ejector handle to inject the controller full y into the chassis frame.
Chapter 2 Installation and Configur ation © National Instruments Corporat ion 2-7 NI PXI-1056 User Manual Figure 2-3. NI PXI Controller Installed in a PXI-1056 Chassis Installing PXI Modules Complete the following steps to inst all a module. 1. Make sure the po wer switch is in the Off (Standby) position.
Chapter 2 Installation and Configuration NI PXI-1056 User Manual 2-8 ni.com Figure 2-4. Installing PXI or CompactPCI Modules Power Switch LED Indicator The chassis power switch has an inte grated LED. This LED indicates the chassis is powered on and operating normally.
Chapter 2 Installation and Configur ation © National Instruments Corporat ion 2-9 NI PXI-1056 User Manual There are six dual-color LED indicators on the front panel of the chassis. Four of the LEDs indicate the status of voltage supp ly regulation (+3.
Chapter 2 Installation and Configuration NI PXI-1056 User Manual 2-10 ni.com Serial Communication Command Set Voltage, temperature, and fan speed statuses may be read using the following defined comm and set.
Chapter 2 Installation and Configur ation © National Instruments Corporat ion 2-11 N I PXI-1056 User Manual T emperature Measurement Commands Note Units are in degrees Celsius.
Chapter 2 Installation and Configuration NI PXI-1056 User Manual 2-12 ni.com Voltage Measurement Commands Note Units are in V DC . SF SF:F1: x < CR><LF> Fan #1, x = OK or F AIL SF:F2: x &l.
Chapter 2 Installation and Configur ation © National Instruments Corporat ion 2-13 N I PXI-1056 User Manual Request for All Status Note V oltage units are in V DC , and temperature units are in degrees Celsius.
Chapter 2 Installation and Configuration NI PXI-1056 User Manual 2-14 ni.com Help Menu Requests Note This is not av ailable on older SMM code versions. PXI System Configuration with MAX Configuration of the PXI system is handled th rough Measurement & Automation Explorer (MAX), incl uded on the NI Driver CD-ROM packaged with your ki t.
Chapter 2 Installation and Configur ation © National Instruments Corporat ion 2-15 N I PXI-1056 User Manual Figure 2-5. Multichassis Configur ation in MAX Basic PXI System Conf iguration 1. Launch MAX. 2. In the Configu ration tree, click on the Devices and Interfaces branch to expand it.
Chapter 2 Installation and Configuration NI PXI-1056 User Manual 2-16 ni.com 5. Apply the chassis number labels (shown in Figure 2-6) included with your kit to each chassis in your PXI system, and write in the chassis number accordingly in the white space.
Chapter 2 Installation and Configur ation © National Instruments Corporat ion 2-17 N I PXI-1056 User Manual Note Selecting any non-disabled routing automa tically reserves the line in all trigger buses being routed to.
© National Instruments Corporat ion 3-1 NI PXI-1056 User Manual 3 Maintenance This chapter describes basic maintenance procedures yo u can perform on the PXI-1056 chassis. Caution Disconnect the power cable prior to servicing the PXI-1056 chassis. Ser vice Interval Clean the chassis fan filter at a maximum in terval of s ix months.
Chapter 3 Maintenance NI PXI-1056 User Manual 3-2 ni.com Interior Cleaning Use a dry, low-velocity str eam of air to clean the inte rior of the chassis. Use a soft-bristle brush for cleaning around components. Exterior Cleaning Cautions A void getting moisture inside the chassis during exterior cleaning, especiall y through the top vents.
Chapter 3 Maintenance © National Instruments Corporat ion 3-3 NI PXI-1056 User Manual Resetting the AC Mains Circuit Breaker If the PXI-1056 is connected to an AC source and encounters an over-current condition, the circuit breaker on the r ear panel w ill trip to prevent damage to the chassis.
Chapter 3 Maintenance NI PXI-1056 User Manual 3-4 ni.com Removal The PXI-1056 power-supply shuttle is a replacement part for the PXI-1056 chassis. Before attempting to replace th e power-supply shuttl e, verify that there is adequate clearance behind the chassis.
© National Instruments Corporat ion A-1 NI PXI-1056 User Manual A Specifications Caution If the PXI-105 6 chassis is used in a manner in consistent with th e instructions or specifications listed by National Instruments, th e protectiv e features of the chassis may be impaired.
Appendix A Specifications NI PXI-1056 User Manual A-2 ni.com Power disconnect .......... .............. ............The AC power cable provides main power disconnect. Depressing the front-panel power switch controls the intern al chassis power supply that provides DC power to the CompactPCI/PXI backplane.
Appendix A Specifications © National Instruments Corporat ion A-3 NI PXI-1056 User Manual Over-curre nt protect ion ... ..... .............. .... All outpu ts protected from short circuit and overload with automatic recovery when the short or overload is removed.
Appendix A Specifications NI PXI-1056 User Manual A-4 ni.com Safety The PXI-1056 was designed to meet the requiremen ts of the following standards of safety for electrical equi pment for measurement, control, and laboratory use: • EN 61010-1, IEC 61010 -1 • UL 61010-1 • CAN/CSA-C22.
Appendix A Specifications © National Instruments Corporat ion A-5 NI PXI-1056 User Manual Environmental Operating temperature........................ .... 0 to 55 °C Storage temperature ................... ............ – 40 to 71 °C Relative humidity Operating .
Appendix A Specifications NI PXI-1056 User Manual A-6 ni.com Backplane Size .............. .............. .............. ......... ......3U/6U-sized; one 3U system slot (with three system expansion slots) and 17 3U peripheral slots, or any combination up to 7 6U cards and 3U cards.
Appendix A Specifications © National Instruments Corporat ion A-7 NI PXI-1056 User Manual Maximum jitter intro duced by backplane circuitry ... ................. . 1 ps RMS in 10 Hz to 1 MHz range Mechanical Overall dimensions (standard chassis) Height.
Appendix A Specifications NI PXI-1056 User Manual A-8 ni.com Figure A-1. PXI-1056 Dimensions (Front and Side) in Inches (mm) 17.00 (431.8) 6.98 (177.4) .
Appendix A Specifications © National Instruments Corporat ion A-9 NI PXI-1056 User Manual Figure A-2. PXI-1056 Dimensions (Bottom) in Inches (mm) 16.06 (407.
Appendix A Specifications NI PXI-1056 User Manual A-10 ni.com Figure A-3 shows the PXI-1056 rack-mount kit components. Figure A-3. PXI-1056 Rack Mount Components 1 PXI-1056 Chassis 2 Rack Mount Bracke.
© National Instruments Corporat ion B-1 NI PXI-1056 User Manual B Pinouts This appendix describes the P1 and P2 connector pinout s for the PXI-1056 backplane. T able B-1 shows the P1 (J1) co nnector pinout for the System Controller slot. T able B-2 shows the P2 (J2) co nnector pinout for the System Controller slot.
Appendix B Pinouts NI PXI-1056 User Manual B-2 ni.com Table B-1. P1 (J1) Connector Pinout for the System Controller Slot Pin Z A B C D E F 25 GND 5V REQ64# ENUM# 3.3V 5V GND 24 GND AD[1] 5V V(I/O) AD[0] A CK64# GND 23 GND 3.3V AD[4] AD[3] 5V AD[2] GND 22 GND AD[7] GND 3.
Appendix B Pinouts © National Instruments Corporat ion B-3 NI PXI-1056 User Manual Table B-2. P2 (J2) Connector Pinout for the System Controller Slot Pin Z A B C D E F 22 GND GA4 GA3 GA2 GA1 GA0 GND .
Appendix B Pinouts NI PXI-1056 User Manual B-4 ni.com Table B-3. P1 (J1) Connector Pinout for the Star T rigger Slot Pin Z A B C D E F 25 GND 5V REQ64# ENUM# 3.3V 5V GND 24 GND AD[1] 5V V(I/O) AD[0] A CK64# GND 23 GND 3.3V AD[4] AD[3] 5V AD[2] GND 22 GND AD[7] GND 3.
Appendix B Pinouts © National Instruments Corporat ion B-5 NI PXI-1056 User Manual Table B-4. P2 (J2) Connector Pinout for the Star T rigger Slot Pin Z A B C D E F 22 GND GA4 GA3 GA2 GA1 GA0 GND 21 G.
Appendix B Pinouts NI PXI-1056 User Manual B-6 ni.com Table B-5. P1 (J1) Connector Pinout fo r the Generic Peripheral Slot Pin Z A B C D E F 25 GND 5V REQ64# ENUM# 3.3V 5V GND 24 GND AD[1] 5V V(I/O) AD[0] A CK64# GND 23 GND 3.3V AD[4] AD[3] 5V AD[2] GND 22 GND AD[7] GND 3.
Appendix B Pinouts © National Instruments Corporat ion B-7 NI PXI-1056 User Manual Table B-6. P2 (J2) Connector Pinout fo r the Generic Peripheral Slot Pin Z A B C D E F 22 GND GA4 GA3 GA2 GA1 GA0 GN.
© National Instruments Corporat ion C-1 NI PXI-1056 User Manual C T echnical Support and Professional Ser vices Visit the following sections of the National Instruments Web site at ni.com for technical support an d professional services: • Support —Online technical support resources at ni.
Appendix C T echnical Support and Professional Ser vices NI PXI-1056 User Manual C-2 ni.com • Calibration Certificate —If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration . If you searched ni.
© National Instruments Corporat ion G-1 NI PXI-1056 User Manual Glossar y Symbol Pref ix V alue pp i c o 1 0 –1 2 nn a n o 1 0 –9 µ micro 10 –6 m milli 10 –3 k kilo 10 3 Mm e g a 1 0 6 Gg i g a 1 0 9 Tt e r a 1 0 12 Symbols ° Degrees. ≥ Equal or greater than.
Glossary NI PXI-1056 User Manual G- 2 ni.com B backplane An assembly , typically a printed circuit board, with con nectors and signal paths that bus the connector pins. BNC Bayonet Neill Concelman connector ; a commonly used coaxial connector . C CC e l s i u s .
Glossary © National Instruments Corporat ion G-3 NI PXI-1056 User Manual E ef ficiency Ratio of output power to inpu t power , expressed as a percentage. EIA Electronic Industries Association. Embedded system controller A module configured for installation in slot 1 of a PXI chassis.
Glossary NI PXI-1056 User Manual G- 4 ni.com I IEC International Electrot echnical Commission; an organization that sets international electrical and electronics standards. IEEE Institute of Electrical and Electronics Engineers. I MP Mainframe peak current.
Glossary © National Instruments Corporat ion G-5 NI PXI-1056 User Manual M m Meters. MAX NI Measurement & Automation Explorer , the utility which allows you to configure and test your PXI system. MHz Megahertz. One million Hertz; on e Hertz equals one cycle per second.
Glossary NI PXI-1056 User Manual G- 6 ni.com PXI PCI eXtensions for Instrumentation. PX I is an implementati on of CompactPCI with added electrical featur es that meet the high performance requirements of in strumentatio n applications by providing trigg ering, local buses, and system clock capabilities.
Glossary © National Instruments Corporat ion G-7 NI PXI-1056 User Manual T TTL T rans istor -trans istor logic. U UL Und erwriter’ s Laboratories. V V V olts.
© National Instruments Corporat ion I-1 NI PXI-1056 User Manual Index A AC power cables (table), 1-2 C cables, power (table), 1-2 calibration certificate (NI resources), C-2 chassis initialization file, 2-17 CompactPCI installing modules (f igure), 2-8 configuration.
Index NI PXI-1056 User Manual I-2 ni.com L local bus routing (figure), 1-7 M maintenance of PX I-1056 cleaning exterior cleaning, 3-2 fan filter, 3- 2 interior cleaning, 3-2 preparation, 3-1 service i.
Index © National Instruments Corporat ion I-3 NI PXI-1056 User Manual star trigger (ST) slot, 1-5 system reference clock, 1-8 trigger bus, 1-8 R rack mount kit dimensions (figu re), A-10 related docu.
デバイスNational Instruments NI PXI-1056の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
National Instruments NI PXI-1056をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNational Instruments NI PXI-1056の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。National Instruments NI PXI-1056の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。National Instruments NI PXI-1056で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
National Instruments NI PXI-1056を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNational Instruments NI PXI-1056の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、National Instruments NI PXI-1056に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNational Instruments NI PXI-1056デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。