National InstrumentsメーカーODC5の使用説明書/サービス説明書
ページ先へ移動 of 34
Product and company names are trademark s or trade names of thei r respective companies. 3 71174A - 0 1 © Copyright 1990, 1998 N a tional Ins t ruments Corp .
SSR Series Modules and Backplanes 2 © National Instruments Corporation What Y ou Need to Get Started To set up and use the SSR Series modules and backplanes you need the following: ❑ SSR Series mod.
© National Instruments Corporation 3 SSR Series Modules and Backplanes The dropout voltage and current specifications for the output modules are giv e n in the Manufacturer Data Sheets section. For most control applications, such as controlling motors or lamps, these requirements are not dif f icult to meet.
SSR Series Modules and Backplanes 4 © National Instruments Corporation The SSR backplanes are di vided into ports of eight modules each. The 8-, 16-, 24-, and 32-module backplanes have one, two, three, and four ports respectiv ely .
© National Instruments Corporation 5 SSR Series Modules and Backplanes Caution Do not attempt to connect the SSR backplane to a host computer DA Q device for which it was not designed. Such connections can damage any or all SSR modules, the host computer , and the D A Q device.
SSR Series Modules and Backplanes 6 © National Instruments Corporation Figure 1. Grayhill 8 Module Backplane Jumper Locations Figure 2. Grayhill 16 Modu le Backplane Jumper Locations Figure 3.
© National Instruments Corporation 7 SSR Series Modules and Backplanes Figure 4. Grayhill 32 Modu le Backplane Jumper Locations Note The Grayhill 32-module backplane can be powered only by an external po wer supply . There are no jumper settings. There is a fuse on the external pow er supply .
SSR Series Modules and Backplanes 8 © National Instruments Corporation Figure 6. Cr ouzet 16 Module Backplane Jumper Locations Figure 7. Cr ouzet 24 Module Backplane Jumper Locations Note The Crouzet 32 module bac kplane has no positio n on the ba ckplan e for eit her a fuse or jumper .
© National Instruments Corporation 9 SSR Series Modules and Backplanes output modules the LED is on when the module is turned on. See the Manufacturer Data Sheets section for further information. Signal Connections Connect external devices to the SSR modules using the screw terminals.
SSR Series Modules and Backplanes 10 © National Instruments Corporation Figure 10. IDC5 Signal Connections Figure 11. ODC5 Signal Connections Manufacturer Data Sheets This section contains the manufacturing data sheets of Grayhill Corporation 1 and Crouzet Corporation 2 .
© National Instruments Corporation 11 SSR Series Modules and Backplanes 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.
SSR Series Modules and Backplanes 12 © National Instruments Corporation 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.
© National Instruments Corporation 13 SSR Series Modules and Backplanes 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com An ISO-9001 Company 70G-ODC 70-ODC 70M-ODC CIRCUITRY Two choices of switching speed vs.
SSR Series Modules and Backplanes 14 © National Instruments Corporation 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com An ISO-9001 Company SPECIFICATIONS Specifications apply over operating temperature range unless noted otherwise.
© National Instruments Corporation 15 SSR Series Modules and Backplanes 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.
SSR Series Modules and Backplanes 16 © National Instruments Corporation 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.
© National Instruments Corporation 17 SSR Series Modules and Backplanes 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com An ISO-9001 Company CIRCUITRY Negative True Logic Modules have either a polarized (Figure 3) or non- polarized (Figure 4) input.
SSR Series Modules and Backplanes 18 © National Instruments Corporation 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.
© National Instruments Corporation 19 SSR Series Modules and Backplanes.
SSR Series Modules and Backplanes 20 © National Instruments Corporation.
© National Instruments Corporation 21 SSR Series Modules and Backplanes.
SSR Series Modules and Backplanes 22 © National Instruments Corporation.
© National Instruments Corporation 23 SSR Series Modules and Backplanes 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com An ISO-9001 Company 8 MODULE RACK–Standard Part No.
SSR Series Modules and Backplanes 24 © National Instruments Corporation 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com An ISO-9001 Company MOUNTING RACKS SCHEMATIC–Part Nos.
© National Instruments Corporation 25 SSR Series Modules and Backplanes 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com An ISO-9001 Company MOUNTING RACKS 55 16 MODULE RACK–Standard Part No.
SSR Series Modules and Backplanes 26 © National Instruments Corporation 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com An ISO-9001 Company SCHEMATIC–Part Nos. 70RCK16 and 70MRCK16 SCHEMATIC–Part No.
© National Instruments Corporation 27 SSR Series Modules and Backplanes 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com An ISO-9001 Company 24 MODULE RACK–Standard Part No.
SSR Series Modules and Backplanes 28 © National Instruments Corporation 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com An ISO-9001 Company MOUNTING RACKS 61 SCHEMATIC–Part Nos.
© National Instruments Corporation 29 SSR Series Modules and Backplanes.
SSR Series Modules and Backplanes 30 © National Instruments Corporation.
© National Instruments Corporation 31 SSR Series Modules and Backplanes.
SSR Series Modules and Backplanes 32 © National Instruments Corporation.
© National Instruments Corporation 33 SSR Series Modules and Backplanes.
SSR Series Modules and Backplanes 34 © National Instruments Corporation.
デバイスNational Instruments ODC5の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
National Instruments ODC5をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNational Instruments ODC5の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。National Instruments ODC5の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。National Instruments ODC5で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
National Instruments ODC5を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNational Instruments ODC5の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、National Instruments ODC5に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNational Instruments ODC5デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。