PXI ™ PXI-1006 User Manual PXI-1006 User Manual February 2001 Edition Part Number 323006 A-01.
Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100 Worldwide Off.
Important Information Warranty The PXI-1006 is warrant ed against defects in materials and workm anship for a period o f one year from the d ate of shipment, as evidenced by receipts or other documenta tion. National Instruments will, at it s option, repair or replace equipment that proves to be defective during the warranty period.
Compliance FCC/Canada Radio Frequency Interference Compliance* Determining FCC Class The Federal Communications Commission (FCC) has rules to protect wireless communications from interference.
Canadian Depart ment of Communications This Class B digital apparatus meets all requirements of the Canadian I nterference-Causing Equipment Regulations. Cet appareil num é rique de la classe B respecte toutes les exigences du R è gleme nt sur le mat é riel brouilleur du Canada.
© National Instruments Corporation vii PXI-1006 User Manual Contents About This Manual Conventions Used in This Manual ................. ............ .............. ........... .............. ............. ix Related Documentation ............... ...
Contents PXI-1006 User Manual viii ni.com Appendix A Specifications Appendix B Pinouts Appendix C Technical Support Resources Glossary Index Figures Figure 1-1. Installing Controller and PXI Modules ................................................. 1-2 Figure 2-1.
© National Instruments Corporation ix PXI-1006 User Manual About This Manual The PXI-1006 User Manual describ es the features of th e PXI-1006 chassis and contains information about configuring the chassis, instal ling the modules, and operating and usin g the PXI-1006.
About This Man ual PXI-1006 User Manual x ni.com • IEEE 1101.10 and P1101.11, IEEE Standard for Addi tional Mechanical Specifications for M icrocomputers Using IEEE 1101.
© National Instruments Corporation xi PXI-1006 User Manual For Y our Safety Caution Before undertaking any troubleshooting, maintenance, or e xploratory procedure, carefully read the warning and caution notices. This equipment contains voltage hazardous to human life and safety , and can inflict personal injury .
© National Instruments Corporatio n 1-1 PXI-1006 User Manual 1 Installing and V erifying Operation This chapter describes how to unpack the PXI-1006 , install a controller, and verify that the chassis is operating correctly.
Chapter 1 Installing and Verifying Operation PXI-1006 User Manual 1-2 ni.com 4. Install your con troller in Slot 1 of your PXI-100 6. Install peripheral cards, if any , in slots 2 through 18 .
© National Instruments Corporatio n 2-1 PXI-1006 User Manual 2 PXI-1006 Features This chapter describes the key features of the PXI-1006 chassis and lists optional equipment you can order from National Instruments.
Chapter 2 PXI-1006 Features PXI-1006 User Manual 2-2 ni.com PXI-1006 Backplane Over view Interoperability with CompactPCI The PXI-1006 backplane is interoperable with PXI-compatible products and standard CompactPCI products.
Chapter 2 PXI-1006 Features © National Instruments Corporatio n 2-3 PXI-1006 User Manual Figure 2-1. Front View of the PXI-1006 Chassis Figure 2-2. Rear View of the PXI-1006 Chassis 1 Remote On/Off (.
Chapter 2 PXI-1006 Features PXI-1006 User Manual 2-4 ni.com System Controller Sl ot The System Controller slo t is Slot 1 of the chassis as defined by the PXI specification. It has three controller expansion slots, which are used for system controller modules that are wider than one slot.
Chapter 2 PXI-1006 Features © National Instruments Corporatio n 2-5 PXI-1006 User Manual Figure 2-3. PXI Local Bus and Star T rigger Routing 3 4 5 6 7 8 9 10 11 12 14 15 13 17 18 16 Local Bus Local B.
Chapter 2 PXI-1006 Features PXI-1006 User Manual 2-6 ni.com T rigger Bus The PXI-1006 has three PXI segments. Vertical bars represent the segment divisions on the front of the chassis. (See Figure 2-1 for the segment di vi der locations.) The PXI trigger bus is di vided into three separate trigger buses at these locations.
Chapter 2 PXI-1006 Features © National Instruments Corporatio n 2-7 PXI-1006 User Manual Remote Power Monitoring and Inhibiting Interface The PXI-1006 chassis supports remote po wer monitoring and inhibiting via a 9-pin D-sub connector located on th e rear panel.
Chapter 2 PXI-1006 Features PXI-1006 User Manual 2-8 ni.com Using the Power Monitoring Feature Y ou can use a digital v oltmeter to ensure all voltage le vels in your PXI-1006 are with in the allo wable limits. Caution When connecting digital v oltmeter probes to the rear D-sub connector , be careful not to short the probe leads together .
Chapter 2 PXI-1006 Features © National Instruments Corporatio n 2-9 PXI-1006 User Manual Installing Filler Panels To optimize module coo ling performance, install filler panel s into unused or empty slots.
Chapter 2 PXI-1006 Features PXI-1006 User Manual 2-10 ni.com Caution A void getting moisture inside th e chassis durin g exterior cleaning. Use just enough moisture to dampen the c loth. Do not wash the front- or rear-panel connectors or switches. Cov er these components while cleaning the chassis.
© National Instruments Corporatio n 3-1 PXI-1006 User Manual 3 T roubleshooting This chapter describes basic troubleshooting procedures you can perform on the PXI-1006 chassis. T roubleshooting the PXI-1006 Refer to Table 3-1 to troubl eshoot the PXI-1006 chassis.
Chapter 3 T roubleshooting PXI-1006 User Manual 3-2 ni.com 3. Depress the circuit breaker to reset it. 4. Reconnect the A C line cord. 5. T urn the power switch to the On position. If the circuit breaker trips again , complete the fol lo wing steps: 1.
© National Instruments Corporation A-1 PXI-1006 User Manual A Specifications This appendix contains specifications for the PXI-1006 chassis. Electrical AC Input Input voltage range.................. .............. . 90 – 264 V AC Input frequency range .
Appendix A Specifications PXI-1006 User Manual A-2 ni.com DC Output Maximum usable power ....... .............. .... 600 W DC current capacity (I MP ) Load regulation Maximum ripple and noise ............... ......1% ripple, 1% noise 20 MHz bandwidth Over -current protection .
Appendix A Specifications © National Instruments Corporation A-3 PXI-1006 User Manual Slot airflo w direction .................. ............ P1 to P2, bottom of module to top of module Module/power supply cooling intake ..... Three rear fans Module cooling exhaust .
Appendix A Specifications PXI-1006 User Manual A-4 ni.com Functional shock (operating) .................. MIL-T -288 00E CLASS 3, Half-Sine Shock Pulse, 11 ms duration, 30 g peak Operating location ......................... .........Indoor use only Random vibration Operational 1 .
Appendix A Specifications © National Instruments Corporation A-5 PXI-1006 User Manual Mechanical W eight ...... ......................... ..................... 13.2 kg (29.2 lb .) Maximum module weight ............. ......... 1.8 kg (4 lb .) Materials.
Appendix A Specifications PXI-1006 User Manual A-6 ni.com Figure A-1 shows the PXI-1006 dimensions. The holes shown are for the installation of the optional r ack-mount kit. Y ou can install thi s kit on the front or rear of the chassis, depending on wh ich end of the chassis you want to face to ward th e front of the i nstrument cabinet.
© National Instruments Corporation B-1 PXI-1006 User Manual B Pinouts This appendix describes th e P1 and P2 connector pinouts for the PXI-1 006 backplane. T able B-1 shows the P1 (J1) connector pinout for the System Controller slot. T able B-2 shows the P2 (J2) connector pinout for the System Controller slot.
Appendix B Pinouts PXI-1006 User Manual B-2 ni.com Table B-1. P1 (J1) Connector Pinout for the System Controller Slot Pin Z A B C D E F 25 GND 5V REQ64# ENUM# 3.3V 5V GND 24 GND AD[1] 5V V(I/O) AD[0] AC K 6 4 # GND 23 GND 3.3V AD[4] AD[3] 5V AD[2] GND 22 GND AD[7] GND 3.
Appendix B Pinouts © National Instruments Corporation B-3 PXI-1006 User Manual Table B-2. P2 (J2) Connector Pinout for the System Controller Slot Pin Z A B C D E F 22 GND GA4 GA3 GA2 GA1 GA0 GND 21 G.
Appendix B Pinouts PXI-1006 User Manual B-4 ni.com Table B-3. P1 (J1) Connector Pinout for the Star T rigger Slot Pin Z A B C D E F 25 GND 5V REQ64# ENUM# 3.3V 5V GND 24 GND AD[1] 5V V(I/O) AD[0] AC K 6 4 # GND 23 GND 3.3V AD[4] AD[3] 5V AD[2] GND 22 GND AD[7] GND 3.
Appendix B Pinouts © National Instruments Corporation B-5 PXI-1006 User Manual Table B-4. P2 (J2) Connector Pinout for the Star T rigger Slot Pin Z A B C D E F 22 GND GA4 GA3 GA 2 GA1 GA0 GND 21 GND .
Appendix B Pinouts PXI-1006 User Manual B-6 ni.com Table B-5. P1 (J1) Connector Pinout for the Peripheral Slot Pin Z A B C D E F 25 GND 5V REQ64# ENUM# 3.3V 5V GND 24 GND AD[1] 5V V(I/O) AD[0] AC K 6 4 # GND 23 GND 3.3V AD[4] AD[3] 5V AD[2] GND 22 GND AD[7] GND 3.
Appendix B Pinouts © National Instruments Corporation B-7 PXI-1006 User Manual Table B-6. P2 (J2) Connector Pinout for the Peripheral Slot Pin Z A B C D E F 22 GND GA4 GA3 GA2 GA1 GA0 GND 21 GND PXI_.
© National Instruments Corporation C-1 PXI-1006 User Manual C T echnical Support Resources W eb Support National Instruments W eb support is your first stop for help in solving installation, configuration, and application pro blems and questions.
Appendix C T echnical Support R esources PXI-1006 User Manual C-2 ni.com W orldwide Support National Instruments has of fices located around the world to help address your support needs. Y ou can access our branch of fice W eb sites from the W orldwide Of fices section of ni.
© National Instruments Corporation G-1 PXI-1006 User Manual Glossar y Pref ix Meanings V alue n- nano- 1 0 – 9 µ- micro- 10 – 6 m- milli- 10 – 3 c- centi- 10 – 2 k- kilo- 10 3 M- mega- 10 6 .
Glossary PXI-1006 User Manual G -2 ni.com B backplane An assembly , typical ly a printed circuit board, with connectors and signal paths that b us the connector pins C CC e l s i u s cfm Cubic feet pe.
Glossary © National Instruments Corporation G-3 PXI-1006 User Manual g RMS A measure of random vibration. The root mean square of acceleration le vels in a random vibration test profile.
Glossary PXI-1006 User Manual G -4 ni.com R RH Relati ve humidity RMS Root mean square. A method used to measure electrical output in v o lts and wat ts S s Seconds ST Star T rigger Star T rigger slot This slot is located at slot 2 and has a dedicated trigger line b etween each peripheral slot.
© National Instruments Corporatio n I-1 PXI-1006 User Manual Index B backplane, 2-2 interoperabilit y with CompactPCI, 2-2 local bus, 2-4 overview, 2-2 peripheral slots, 2-4 specifications, A-4 Star .
Index PXI-1006 User Manual I-2 ni.com M maintenance of PXI-1006, 3-1 cleaning exterior cleaning, 2-9 fan filters, 2-10 interior cleaning, 2-9 resetting the AC m ains circuit breaker, 3-1 troubleshooti.
Index © National Instruments Corporatio n I-3 PXI-1006 User Manual R rack mounting, 2-6 remote power monitoring and i nhibiting interface, 2-7 S safety ground, connecting, xi safety specifications (t.
デバイスNational Instruments Part Number 323006A-01の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
National Instruments Part Number 323006A-01をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNational Instruments Part Number 323006A-01の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。National Instruments Part Number 323006A-01の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。National Instruments Part Number 323006A-01で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
National Instruments Part Number 323006A-01を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNational Instruments Part Number 323006A-01の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、National Instruments Part Number 323006A-01に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNational Instruments Part Number 323006A-01デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。