PXI PXI-PCI 8330 Series User Manual MXI-3 Multi-System Extension Interface for PCI, CompactPCI, and PXI Bus Computers PXI-PCI 8330 Series User Manual September 1999 Editio n Part Number 370103A-01.
Worldwide Technical Support and Product Info rmation www.natinst.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100 Worldwide O.
Important Information Warranty The PXI-PCI 8330 Series hardw are is warrant ed ag ainst defects i n ma te rials an d wo rkmans hi p for a p e riod o f on e year from the date of shipm ent, as evidenced by receipts or ot her documentation.
Compliance FCC/DOC Radio Frequency Interference Class A Compliance This equipment generates and uses radio frequency energy and, if not installed and used in strict accordance with the instructions in this manual, may cause interference to radio and television reception.
© National Instruments Corporation v PXI-PCI 8330 Series User Manual Contents About This Manual Conventions ............ .............. .............. .............. .............. .............. ............... ................ .. v ii Related Documentation .
Contents PXI-PCI 8330 Series User Manual vi www.natinst.com Appendix A Specifications Appendix B Technical Support Resources Glossary Index Figure Figure 2-1. Installing the PCI MXI-3 ........................ ................. ................. ......
© National Instruments Corporation vii PXI-PCI 8330 Series User Manual About This Manual This manual describes the features, functions, and operation of the PXI-PCI 8330 Series. The four products in this series are the PCI-833 0, the PXI-8330, the PCI-8335, an d the PXI-8335.
About This Manual PXI-PCI 8330 Series User Manual viii www.natinst.com Related Documentation The following documents contain information that you might find helpful as you read this manual: • Set Up Your MXI-3 System • Y our computer or chassis documentation • PXI Specification , revision 1.
© National Instruments Corporation 1-1 PXI-PCI 8330 Series User Manual 1 Introduction This chapter describes the PXI-PCI 8330 Series, lists what you need to get started, and explains ho w to unpack and set up your hardware. The four products in this series are the PCI-8330, th e PXI-8330, the PCI-8335, and the PXI-8335.
Chapter 1 Introduction PXI-PCI 8330 Series User Manual 1-2 www .natinst.com Software T ransparency Because the MXI-3 system is a PCI-PCI b ridge , all devices on the system appear as local devices to the primary computer. You do not need to rewrite your device drivers for operation on a MXI-3 system.
Chapter 1 Introduction © National Instruments Corporation 1-3 PXI-PCI 8330 Series User Manual 3. Remov e the device from the package and inspect the de vice for loose components or any other signs of damage. Notify National Instruments if the de vice appears damaged in any way .
© National Instruments Corporation 2-1 PXI-PCI 8330 Series User Manual 2 Installation This chapter explains how to install the MXI-3 software and hardware. Software Installation Your MXI-3 kit includes a setup program for Microsoft Windows operating system.
Chapter 2 Installation PXI-PCI 8330 Series User Manual 2-2 www .natinst.com Hardware Installation You can install a MXI-3 card in any available PCI expansion slot in your PC. The follo wing are general instructions for installing the PCI MXI-3 and PXI MXI-3 cards.
Chapter 2 Installation © National Instruments Corporation 2-3 PXI-PCI 8330 Series User Manual Figure 2-1. Installing the PCI MXI-3 Installing a PXI MXI-3 Card Y ou can install the PXI MXI-3 in any a vailable 5 V slot in your PXI or CompactPCI chassis.
Chapter 2 Installation PXI-PCI 8330 Series User Manual 2-4 www .natinst.com 3. Remove or open any doors or covers blocking access to the system controller slot (Slot 1) in the mainframe. 4. Touch the metal part of the case to discharge any static el ectricity that might be on your clothes or body.
Chapter 2 Installation © National Instruments Corporation 2-5 PXI-PCI 8330 Series User Manual Figure 2-2. PXI MXI-3 Before Installation Cabling 1. Connect the appropriate serial cable to both primary and secondary MXI-3 cards. If you are using a f iber-optic cable, be sure to remo ve the protecti ve caps from the c onnectors.
© National Instruments Corporation 3-1 PXI-PCI 8330 Series User Manual 3 Hardware Over view This chapter presents an overview of th e hardware functions of your MXI-3 system, and explains the operation of each functional unit. Functional Over view The MXI-3 system is a PCI-PCI bridge that needs no software for normal operation.
Chapter 3 Hardware Over view PXI-PCI 8330 Series User Manual 3-2 www .natinst.com Figure 3-1. MXI-3 Block Diagram MXI-3 Chassis Expansion By plugging a PXI MXI-3 module into any of slots 2 through 8 o.
Chapter 3 Hardware Overview © National Instruments Corporation 3-3 PXI-PCI 8330 Series User Manual Figure 3-2. Basic MXI-3 Con figurations Because MXI-3 complies with the standard PCI-to-PCI bridging specification, it can tak e adv antage of a v ariety of other e xtension configurations.
Chapter 3 Hardware Over view PXI-PCI 8330 Series User Manual 3-4 www .natinst.com Star configurations are also possible using MXI-3 interf aces in the primary system to f ine tune performance.
Chapter 3 Hardware Overview © National Instruments Corporation 3-5 PXI-PCI 8330 Series User Manual Serial T ransmitter The serial transmitter is a parallel-to-serial data converter. The parallel-to-serial converter serializes the 2 0-bit wide parall el data from the MXI-3 ASIC and sends it to the transceiver.
Chapter 3 Hardware Over view PXI-PCI 8330 Series User Manual 3-6 www .natinst.com If you require lengths greater than 30 meters in fiber optic cable, contact Molex, cable vendor for National Instruments. T able 3-2 describes Molex cables. The fiber -optic cable offered b y Molex is a multimode, 62.
© National Instruments Corporation A-1 PXI-PCI 8330 Series User Manual A Specifications This appendix lists the system specif ications for PCI MXI-3 and PXI MXI-3 cards. These specifications are typical at 25 °C, unless otherwise stated. Physical Dimensions PCI .
© National Instruments Corporation B-1 PXI-PCI 8330 Series User Manual B T echnical Support Resources This appendix describes the comprehensiv e resources a v ailable to you in the T echnical Support.
Appendix B T echnical Support Resources PXI-PCI 8330 Series User Manual B-2 www .natinst.com Software-Related Resources • Instrument Driver Network —A library with hundreds of instrument dri v ers fo r control of standalone instruments via GPIB, VXI, or serial interfaces.
© National Instruments Corporation G-1 PXI-PCI 8330 Series User Manual Glossar y Pref ix Meaning V alue n- nano- 10 –9 µ- micro- 10 –6 m- milli- 10 –3 c- centi- 10 –2 k- kilo- 10 3 M- mega- .
Glossary PXI-PCI 8330 Series User Manual G-2 www .natinst.com C C Celsius clock hardware component that controls timing for reading from or writing to groups counter/timer a circuit that cou nts external pulses or clock pu lses (timing) D de vice a plug-in instrument card or pad that can contain multiple channels and con v ersion de vices.
Glossary © National Instruments Corporation G-3 PXI-PCI 8330 Series User Manual PCI-MITE A custom ASIC designed by National Instruments that implements the PCI b us interface. The PCI-MITE supports b us mastering for high speed data transfers ov er the PCI b us.
© National Instruments Corporation I-1 PXI-PCI 8330 Series User Manual Index A additional MXI-3 configurations (figure), 3-4 ASIC, 3-4 B basic MXI-3 configurations (figure), 3-3 block diagram, 3-2 C .
Index PXI-PCI 8330 Series User Manual I-2 www .natinst.com O online problem-solving and diagnostic resources, B-1 overview functional unit descriptions, 3-4 hardware, 3-1 MXI-3 block diagram, 3-2 P PC.
デバイスNational Instruments PXI-PCI 8330 Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
National Instruments PXI-PCI 8330 Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNational Instruments PXI-PCI 8330 Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。National Instruments PXI-PCI 8330 Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。National Instruments PXI-PCI 8330 Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
National Instruments PXI-PCI 8330 Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNational Instruments PXI-PCI 8330 Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、National Instruments PXI-PCI 8330 Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNational Instruments PXI-PCI 8330 Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。