National InstrumentsメーカーUSB-6525 data aquisition (DAQ) deviceの使用説明書/サービス説明書
ページ先へ移動 of 16
USER GUIDE AND SPECIFICATIONS NI USB-6525 This user guide describes how to use the National Instruments USB-6525 data acquisi tion (D A Q) de vice. Introduction The NI USB-6525 is a full-speed USB 2.
USB-6525 User Guide an d Specifications 2 ni.com Figure 2. USB-6525 Back View Installing Software Software suppo rt for the USB-6525 for Wind ows 2000/XP is provided by NI-DAQmx. The NI-D A Q mx CD contains example programs th at you can use to get started programming with the USB-65 25.
© National Instruments Co rporation 3 USB-6525 User Guide and Specifications Refer to the Safety G uidelines section of this document for im portant safety information. Setting Up Hardware Complete the f ollowing st eps to set up the hardwa re: 1. Install combicon scr e w terminal blocks by inserting them into th e combicon jacks.
USB-6525 User Guide an d Specifications 4 ni.com I/O Connector The USB-6525 device ships with two d etachable terminal blocks for digital signals. Each indivi dual terminal accepts a wire gauge between 16 AWG–28 AWG. Table 1. Digital T erminal Assignments Module T erminal Signal Module T erminal Signal 1 P0.
© National Instruments Co rporation 5 USB-6525 User Guide and Specifications Signal Descriptions Table 2 describes the signals available on the I/O connectors. Digital I/O USB-6525 has eight channel-to-channel op tically isolated inputs, P1.<0..7>, and eight chann el-to-channel optically isolated solid-state relay outputs, P0.
USB-6525 User Guide an d Specifications 6 ni.com Applying a DC voltage of at least 3.2 V across two input terminals registers logic high. Applying no voltage or a voltage dif ference of 1 V or less registers logic lo w . DC voltages between 1 V and 3.
© National Instruments Co rporation 7 USB-6525 User Guide and Specifications Solid-State Relay (SSR) Outputs You can connect loads to the USB-6525. Connect the load to one of the leads of the power source. Connect either the P0. x A or the P0. x B terminal to the load and the other terminal to the other lead of the AC or DC power source.
USB-6525 User Guide an d Specifications 8 ni.com Figures 7 and 8 show examples of us ing an external flyback diode to protect DC inductiv e loads and an MO V to protect A C inducti ve loads, respecti vely . Figure 7. Contact Protection for DC Inductive Load s Figure 8.
© National Instruments Co rporation 9 USB-6525 User Guide and Specifications Using the USB-6525 as a TTL Output Device Figure 9 shows a sign al connection example for a TTL-level application with an external supply voltage of +5 V.
USB-6525 User Guide an d Specifications 10 ni.com Input current ........... .............. .............. ....3.0 mA/channel max Solid-State Relay Outputs Number of output channels ................. ....8, ch-ch isolated Relay type ...................
© National Instruments Corporation 11 USB- 6525 User Guide an d Specifications Power Requirements USB Input voltage ............ ........... ............ 4.5 to 5.25 VDC in configured state Active current ....... .............. ........... . 150 mA max Suspend current.
USB-6525 User Guide an d Specifications 12 ni.com Isolation Channel-to-channel ............. .............. ......60 VDC continuous Channel-to-earth ground ....... ...... ............60 VDC continuous Withstand . .......... .............. ........... .
© National Instruments Corporation 13 USB- 6525 User Guide an d Specifications CE Compliance This product meets the essential re quirements of applicable European Directives, as amended for CE markin.
USB-6525 User Guide an d Specifications 14 ni.com Operate the device only at or belo w Pollution Degree 2. Pollution is foreign matter in a solid, liquid, or gaseous state that can reduce dielectric strength or surface resisti vity .
© National Instruments Corporation 15 USB- 6525 User Guide an d Specifications • Measurement Category III is for measurements performed in the building installation at the distribution le vel. This cate gory refers to measurements on hard-wir ed equipment such as equipment in f ixed installations, distribution boards, and circuit breakers.
National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for more information abou t National Instruments trademarks. Other product and compan y names mentioned herein are trademarks or t rade names of their respective companie s .
デバイスNational Instruments USB-6525 data aquisition (DAQ) deviceの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
National Instruments USB-6525 data aquisition (DAQ) deviceをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNational Instruments USB-6525 data aquisition (DAQ) deviceの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。National Instruments USB-6525 data aquisition (DAQ) deviceの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。National Instruments USB-6525 data aquisition (DAQ) deviceで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
National Instruments USB-6525 data aquisition (DAQ) deviceを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNational Instruments USB-6525 data aquisition (DAQ) deviceの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、National Instruments USB-6525 data aquisition (DAQ) deviceに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNational Instruments USB-6525 data aquisition (DAQ) deviceデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。