NCR 7455 Retail Terminal Release 1.0 Site Preparation 18427 1 2 3 4 5 6 7 8 9 0 B005-0000-1286 Issue A.
The products described in this boo k are licensed pr oducts of NCR Corporation. NCR is a registered trademark of NCR Corporation. Pentium is a registered trademark of Intel Corporation. It is the policy of NCR Corporation (NCR) to improve pro ducts as new technolo gy, components, softw are, and firmw are become available.
Site Preparation i Preface Audience This book is written for hardware i nstaller/ service person nel, system integrators, and field engineers. Notice: T his document is NCR proprietary information a nd is not to be disclosed or reproduced without co nsent.
ii Site Preparation Lithium Battery Warning Caution: Danger of explosion if battery is incorrectly repl aced. Replace only with the same or equivalent type as recommended by the manufacturer. Discard used batteries a ccording to t he manufac turer's instructions.
Site Preparation iii This book contain s the i nformation necess ary for the preparatio n of a site that conforms to NCR spec ificatio ns. It is very important that th e site complies wit h the requir.
iv Site Preparation Finally, only t he customer can k now the full extent o f damage that may be caused to his business by reason of failure of the equipment which is to be installed.
Site Preparation v Table of Contents Introduction ......................................................................... 1 Interpreting the Model Number ....................................... 2 Related Site Preparation Data .......................
vi Site Preparation NCR 5972 2x20 Remote Post Customer Display .... 17 NCR 5973 International Remote Pos t Customer Display ......................................................................... 18 NCR 5972 Remote Table-Top Customer Display .. 19 NCR 2336-K007 External CD-ROM Dri ve .
Site Preparation vii AC Power Line Trans ient Prote ction 1 Data Line Transient Protection ......................................... 2.
viii Site Preparation Revision Record Issue Date Remarks A April 01 First issue.
Site Preparation ix Radio Frequency Interfere nce Stateme nts Federal Communications Commission (FCC) Informat ion to User This equipment has been tested and found to comply with the l imits for a Cla ss A digital device, pursuant to Pa rt 15 of FCC Rules .
x Site Preparation Declaration o f Conf ormity Manufacturer’s Name NCR Corporation Manufacturer’s Address NCR Corporation Retail Solutions Divisio n 2651 Satellite Boulevard Duluth, GA 30096-581 0 Type of Equipment Information Tech nology Equipme nt Model Number Class 7455 Electrical Ra tings (Input) 100-240 V, 2.
Site Preparation Introduction 18427 1 2 3 4 5 6 7 8 9 0 This document provides the information necessary to prepare a site to NCR specifications prior to i nstalli ng a termina l.
2 Site Preparation Interpreting the Model Number 22 = Base Unit with 12.1" LCD (Release 1) 18043 Language 01 = International English Power Required 80 = 110 -240 VAC 50/60 Hz NCR Model 74xx 2 2 X.
Site Preparation 3 Related Site Preparation Data AC Power and Communications Wiring Title Order Number NCR Ethernet Communication s Wiring Guide BST0-2118-82 NCR Terminal AC Power Wir ing Guideli nes .
4 Site Preparation How to Order Information Products are av ailable t hrough several di fferent c hannels. You need an order form if you are using fax, e-mail, or ma il order. Order forms are available to NCR personne l through QuickLook. I n QuickLook, click on Fo rms & Te mplate s , then select In for mation Products Order Form .
Site Preparation 5 Customer Respo nsibili ties Before the system can be instal led, the customer must do or provide the follow ing: • When required by NCR, provide t he NCR Customer Services represe.
6 Site Preparation AC Store Wiring Req uirements The customer must provide suitable AC po wer for the retai l terminals, associated equipment, and devices. A dedicated unswitc hed power line dedicated to th e NCR equipment i nstallat ion is recomme nded.
Site Preparation 7 System Configura tion Dia gram 7162 7158 7880 Scanner/Scale 7892 Bi-modal Presentation Scanner 1 2 3 4 5 6 7 8 9 0 18984 CRT Operator or Customer Display 5972-1000 Customer Display .
8 Site Preparation Physical Considerations This sectio n presents the followi ng retail termi nal i nformation: • Operating and serv ice clearan ce requirements • Display mounting consideratio ns .
Site Preparation 9 Operating and Service Clearance Requirements Location Component Distance Reason Above 7158 Printer 305 mm (12 in.) Clearance to raise printer co ver 7162 Printer 197 mm (7.75 in.) Clearanc e to raise printer co ver 7166 Printer 280 mm (11 in.
10 Site Preparation Component Dimensions NCR 7455 with Integrated Custom er Display and PCMCIA 18818 1 23 4 56 7 8 9 466 mm (18.3 in.) 380 mm (15.0 in.
Site Preparation 11 NCR 7455 with Integrated P ost Customer Displa y 12 3 456 7 89 406 mm (16.0 in.) 480 mm (19.0 in.) 475 mm (18.7 in.) 18817 7453-K005 C ash Drawer 18038 455.6 mm ( 17.94in.) 108 mm (4.25 in.) 450.9 mm (17.75 in.) 263.5 mm (10.375 in.
12 Site Preparation NCR 2189 Cash Dra wer 16676 133 mm (5.25 in.) 330 mm (13 in.) (18.25 in.) Operating and Service Clearance for Drawer 464 mm 527 mm (20.5 in.) NCR 2113 Cash Dra wer 17310 96 mm (3.75 in.) 400 mm (15.75 in.) 450 mm (17.75 in.) 254 mm (10 in.
Site Preparation 13 NCR 7162 Rece ipt Printer 16099 148mm (5.5 in.) 165 mm (6.5 in.) 240 mm (9.45 in.) NCR 7194 Thermal Receipt Printer 16492 130 mm (5.
14 Site Preparation NCR 7166 Thermal Receipt/Impa ct Printer 171 mm (6.75 in.) 248 mm (9.75 in.) 330 mm (13.00 in.) 280 mm (11.00 in.) 17308 NCR 7158 Thermal Receipt/Impa ct Printer 165 mm (6.50 in.) 336 mm (13.25 in) 229 mm (9.00 in) 305 mm (12.00 in.
Site Preparation 15 NCR 7196 Thermal Receipt Printer 108 mm (4.25 in.) 140 m (5.50 in.) 146 mm (5.75 in.) 254 mm (10.00 in.) 17306.
16 Site Preparation NCR 7455 - 4x2 0 Remote Post Customer Display 18819 95 mm (3.75 in.) 506 mm (22.1 in.) 50 mm (3.5 in.) 95 mm (3.75 in.) 180 mm (7 in.
Site Preparation 17 NCR 5972 2x20 Remote Post Customer Displ ay 262 mm (10.3 in.) 15708 95 mm (3.75 in.) 506 mm (22.1 in.) 30 mm (1.2 in.) 95 mm (3.75 in.
18 Site Preparation NCR 5973 International Re mote Post Customer Displ ay 350 mm (13.8 in.) 45 mm (1.8 in.) 95 mm (3.75 in.) 95 mm (3.75 in.) 110 mm (4.
Site Preparation 19 NCR 5972 Remote Tabl e-Top Customer Display 17237 262 mm (10.3 in.) 158 mm (6.2 in.) 173 mm (6.8 in.) 110 mm (4.3 in.) 45 mm (1.8 in.
20 Site Preparation NCR 2336-K007 E xternal CD-ROM Drive 23 m m (0.9 in.) 155 m m (6.1 in.) 218 m m (8.6 in.) 16951 Note: Allow 75 mm (3 in. ) cleara nce in t he back of t he NCR 2336-K0 07 External CD-ROM Drive for connector and cable clearance. NCR 2336-K008 USB RS-23 2 Port Ser ver 183 mm (7.
Site Preparation 21 Component Weights The follow ing table s hows the compo nent weig hts for eac h integrated component. Retail Terminal Components Weight kg. lbs. 2189 Cash Drawer 9.5 20.9 7453-K005 Cash Dra wer 11.4 25.15 7455 4x20 Remote Customer Display 0.
22 Site Preparation Ventilation Clearance Leave the minimum cl earances s hown be low for proper cooling conditions for t he 7455 Class Reta il Terminal. 18392 1 23 45 6 7 8 9 76 mm (3 in.) Minimum Vertical Clearance Minimum Horizontal Clearance 25 mm (1 in.
Site Preparation 23 Power Requirements Core module contain a three -wire, si ngle-pha se, selectab le 120/240 volt AC, 95 Watt power supply. The supply po wers the retai l terminal, DynaKey, MSR, some scan ner, VFD display, keyboard, USB interface, cash drawer, and PC MCIA cards.
24 Site Preparation Cable Routin g Considera tions External cables can be routed out the back o f the Table -Top Mount. The internal ca ble con nectors on th e terminal are located on the underside of the Core Module under t he Cable Cover.
Site Preparation 25 Considerations for Enclosed Installations Thermal Test Points With the terminal installed in the enclosure, verify that the temperature does not exceed 45 o C (1 15 o F) in the operating environment. Test the temperature at the rear access pane l covering t he CD-ROM and hard drive.
26 Site Preparation System Cables Cable Type Cable Name NCR Part No. Corp. ID No Approximate Cable Lengths Cash Drawer Dual Drawer, Y cable 497-0409394 1416-C372-0006 0.
Site Preparation 27 Cable Type Cable Name NCR Part No. Corp. ID No Approximate Cable Lengths Printer Extender Drop Cables (7453-K641) 7162/7166/7 196 Printer/Workstation 497-041 1815 1416-C417-00 40 4.
28 Site Preparation Cable Illustrations Dual Cash Drawer, Y-cable 15808 51 m m (2.0 in .) 16 m m (0.625 in.) Access Hole Di ameters Cash DWR. #1 Cash DWR.
Site Preparation 29 Printer Interface Cab les (RS-232) 7162/7166/7196 13224 63.5 m m (2.5 in.) 38 mm (1.5 in.) Access Hole Diameter s Printer 497-0407427 - 1 m 497-0407429 - 4 m 497-0407430 - 15 m Workstat ion RS-232 Port 9-pin D-shell Receptacle 25-pin D-shell Plug 7194/7158 13223 38 mm (1.
30 Site Preparation NCR 5972 Remote Customer Di splay and Adapter Cables 1 6291 T o P ower B rick 8 -pin M icrofit R eceptacl e T o C ustomer D isplay To C ust. Displa y P ort 4 97-04056 76 - 4 M 1 416-C278-00 40 2 5-pin D -Shell R eceptacl e 2 4-pin M icrofit R eceptacl e 2 5 mm ( 1.
Site Preparation 31 External CD-ROM Cable 1 6959 T o CD-ROM P ower C onnect or S MK 2 mm Plu g T o CD-ROM P arallel C onnect or 4 97-04130 11 - 0.6 M 1 416-C464-00 06 2 5-pin D -Shell R eceptacl e 2 8-pin S ub-Miniture D -Plug 3 1 mm ( 1.25 in.) 5 7 mm ( 2.
32 Site Preparation Automatic Change Dispenser Serial Cab le 18056 497-0404832 9-Pin D-shell Receptacle 25-pin D-shell Plug P2 1 6 5 9 P1 1 14 13 25 Power, AC 15405 45 mm (1.
Site Preparation 33 Environmen tal Requireme nts Barometric Pressure The 7455 Retail Terminal is designed to operate with in the follo wi ng barometric pressure conditions: • Maximum operating alti tude: 3000 m (9843 ft) • Operating range of pressure: 1 05 kPa to 69 k Pa (15.
34 Site Preparation.
Appendix A: Transient Protection AC Power Li ne Transient Pro tection In the process of power dis tribution, tra nsient el ectrical e nergy (including, but not limited to, lightning strikes, intermittent short circuits, and s witching tra nsients ) can be introduced onto po wer lines.
A-2 Appendix A: Transient Protection • Be listed by the accepted safe ty organization for t he country involved (UL, CS A, VDE, ETL, and so on ) and t he instal lation must conform to local, state, and national electrical codes and regulations.
Index A-i Index —2— 2336-K007 External CD -ROM Drive, 20 2336-K008 USB RS-232 Port Server, 20 —4— 4x20 Remote Customer Display, 16 —5— 5972-1000 Remote Customer Display, 17 5973 Internatio.
ii Index —N— NCR 2113 Cash Drawer, 12 NCR 2189 Cash Drawer, 12 —O— Operating range of barometric pressure, 33 —P— Power requirements, 23 Printer 7158 Thermal Receipt/Impact Printer, 14 716.
.
B005-0000-1286 April 2001 Printed on recycled p aper.
デバイスNCR 7455の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
NCR 7455をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNCR 7455の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。NCR 7455の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。NCR 7455で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
NCR 7455を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNCR 7455の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、NCR 7455に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNCR 7455デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。