MAY, 2000 NEC America, Inc. ND-70185 (E) ISSUE 3 STOCK # 200869 Fusion Net work Syst em Manual ®.
LIABILITY DISCLAIMER NEC America, I nc. reserves t he right to change th e specificati ons, functions, or features, at any time, wit hout no tice. NEC America, Inc. ha s prepared this document for use by its employees and customers. The informati on contained herein i s the propert y of NEC America, Inc.
ISSUE 1 ISSUE 2 ISS UE 3 ISS U E 4 D A TE JANU AR Y , 1998 D A T E MARCH, 1 999 D A TE MA Y , 2000 D A TE ISSUE 5 ISSUE 6 ISS UE 7 ISS U E 8 DA T E DA T E DA T E DA T E NEAX240 0 IMX Fusion Net work System Manual Issue Re v ision Sheet 1/3 ND-70185 (E) ISSUE 3 PA G E N o .
ISSUE 1 ISSUE 2 ISS UE 3 ISS U E 4 D A TE JANU AR Y , 1998 D A TE MARCH, 1999 DA TE MA Y , 2000 D A TE ISSUE 5 ISSUE 6 ISS UE 7 ISS U E 8 DA T E DA T E DA T E DA T E NEAX240 0 IMX Fusion Net work Syst.
ISSUE 1 ISSUE 2 ISS UE 3 ISS U E 4 D A TE JANU AR Y , 1998 D A TE MARCH, 1999 DA TE MA Y , 2000 D A TE ISSUE 5 ISSUE 6 ISS UE 7 ISS U E 8 DA T E DA T E DA T E DA T E NEAX240 0 IMX Fusion Net work Syst.
ND-70185 (E ) ISSUE 3 MAY, 2000 NEAX2400 IMX Fusion Netw or k System Manual T ABLE OF CONTENTS Pag e ND-70185 (E) T ABLE OF CONTENTS Pag e i Revision 3.0 CHAPTER 1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T ABLE OF CONTENTS ND-70185 (E) Pa g e i i Revision 3.0 T ABLE OF CONTENTS (CONTINUED) Pag e 3. Mounting Circui t Cards in PIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 3.1 Mountin g HUB ( P A-M96) in a PIM .
ND-70185 (E) T ABLE OF CONTENTS P age iii Re visio n 3.0 T ABLE OF CONTENTS (CONTINUED) Pag e 8. Office Data S heets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 12 8.
T ABLE OF CONTENTS ND-70185 (E) Pa g e i v Revision 3.0 T ABLE OF CONTENTS (CONTINUED) Pag e CHAPTER 7 TROUBLESHOO TING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 1. List of Fusion -related S ystem Messages .
LIST OF FIGURES Figure Title Pa g e ND-70185 (E ) LIST OF FIGURES Pa g e v Re visio n 3.0 Figure 2-1 Telephone N umber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 2-2 Free Locatio n .
LIST OF FI GU RES ND-70185 (E ) Pa g e v i Revision 3.0 LIST OF FIGURES (CONTINUED) Figure Title Pa g e Figure 5-2 Fusion-CCIS Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Figure 5-3 How to Upgr ade the Numberi ng Pla n Data of an Exist i ng CCIS Network .
ND-70185 (E ) LIST O F FIGURES Pag e v i i Re visio n 3.0 LIST OF FIGURES (CONTINUED) Figure Title Pa g e Figure 5-51 Sa mple Data As signment (ACRD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 Figure 5-5 2 Sample Da ta Assignm ent (ACTK) .
LIST OF FI GU RES ND-70185 (E ) P ag e viii Revision 3.0 LIST OF FIGURES (CONTINUED) Figure Title Pa g e Figure 8-1 Network C onnect ion T ype . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 0 Figure 8-2 NEAX200 0 IVS 2 t o NEAX240 0 IMX Conn ection .
LIST OF T ABLES T able Title Pa g e ND-70185 (E ) LIST OF T ABLES Pag e i x Revision 3.0 Table 4-1 SENSE Swit ch Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 4-2 MODE Sw itch Setti ng.
LIST OF T AB LE S ND-70185 (E ) Pa g e x Revision 3.0 This page is for your notes..
ND-70185 (E) CHAPTER 1 Page 1 Revision 3. 0 CHAPTER 1 I NTR ODUCTION 1. General This man ua l cove rs the inst alla tion o f the Fu sion sy ste m. 2. How to Fo llow This Manual This man ual c ons ists of the fo llow ing cha pters . • CHAPTER 1 (INTR O DUCTION) Explains how to use th is manual.
CHAPTER 1 ND-70185 (E) Page 2 Revision 3. 0 INTRODUCTION Related Ma nua ls 3. Related Manuals To comp lete th e in s t a ll atio n of th e Fusio n sy s tem, th e fo ll owin g man ua ls ar e requ ir ed.
ND-70185 (E) CHAPTER 2 Page 3 Revision 3. 0 CHAPTER 2 G ENERAL 1. What is Fusion and its Ad vantages The main ad vantages of the Fu sion network are as follows: 1.
CHAPTER 2 ND-70185 (E) Page 4 Revision 3. 0 GENERAL Free Numberin g 2. Free Numbering A Telephone Numbe r can be assi gned to a desired sta tion on the Fus ion network using the simple command operati on shown bel ow.
ND-70185 (E) CHAPTER 2 Page 5 Revision 3. 0 GENERAL Fusion Sy s tem Conf igu ra tio n 3. Fusion System Configuration The Fusion syst em can be divided into the fol lowi ng two ty pes . Figure 2-4 shows a Fusion system with Fusion Call Cont rol Handler (FCH) cards.
CHAPTER 2 ND-70185 (E) Page 6 Revision 3. 0 GENERAL Node 4. Node A Fusion n etwork consists of the follow ing types of nodes : • Netw ork Contro l Node Networ k Control Node , which must be assigned on a Fusion network, manages other nodes on t he networ k.
ND-70185 (E) CHAPTER 2 Page 7 Revision 3. 0 GENERAL Dat a Memory Confi gur ation 5. Data Memor y Configuration Each node o n a Fusion network has the foll owing three kinds of Data Memory: • Data Memor y (DM) • Loca l Data Memo ry ( LDM) • Network Data Memory (NDM) - Programmable only by the NCN.
CHAPTER 2 ND-70185 (E) Page 8 Revision 3. 0 GENERAL Fusion Netw ork Examp les When t he ND M (ma ste r) is m odifi ed, the new d ata i s a utom atic ally co pied . Figure 2-8 Network Data M emory Copy 6. Fusion Network Exampl es Figure 2- 9 and Figure 2-1 0 show examples of Fusion networ ks.
ND-70185 (E) CHAPTER 2 Page 9 Revision 3. 0 GENERAL Fusion Netwo rk E xa mpl es Figure 2-10 Open Numbering Fusion-CCIS Network [condit i ons for T elephone Numb er Digi ts] When inco rporatin g the Fu.
CHAPTER 2 ND-70185 (E) Page 1 0 Revision 3. 0 GENERAL T ande m Connecti ons vi a Fusi on Link 7. T andem Connections via Fusion Link Tandem connec tions via FCCS-ACIS can be established . In Figure 2-11 , STN (A) can place a tandem ca ll via FCCS-ACIS.
ND-70185 (E) CHAPTER 3 Page 11 Revision 3. 0 CHAPTER 3 SYSTEM CONFIGURA TION Fusion systems can be divi ded into the following two types: • Fusio n system wit h FCH • Fusio n system wit hout FCH Note: Fusion Cal l Contr ol Handler ( FCH): P A-FCHA This chapter e xplains the syst em configuratio n of each Fusi on system.
CHAPTER 3 ND-70185 (E) Page 1 2 Revision 3. 0 SYSTEM CONFIGURA TION Fusio n System wi th FCH 2. Fusion System with FCH 2.1 S ystem Configuration A sample Fu si on system conf igu ration that us es a DTI to carry D- cha nnel is sho wn belo w . In thi s c onf igu- ration , the Fusio n link is establis hed between nodes via the T1 link .
ND-70185 (E) CHAPTER 3 Page 13 Revision 3. 0 SYSTEM CONFIGURA TION Fusion Sy s tem with F CH In Figure 3-3 LANI , HUB, FCH, and DTI a re sho wn in a fully redundant conf iguration. This co nfi guratio n is av ai la ble fo r Re lea se 3 or la te r soft war e.
CHAPTER 3 ND-70185 (E) Page 1 4 Revision 3. 0 SYSTEM CONFIGURA TION System Consi der ations In Figure 3-6 , n o redundanc y is shown in th e Fusion link. Fig ure 3 -6 N on-Redundant Configuration 3. System Considerations 3.1 Fusion Ne twor k Conditions This section explains how to design a Fusion network.
ND-70185 (E) CHAPTER 3 Page 15 Revision 3. 0 SYSTEM CONFIGURA TION System C onsid erations Condition 2: A maximum of four (4) nodes can be connected as tandem nodes. Figure 3-8 Fusion Tandem Connections Conditio n 3: The av ailabl e connectio n-rout e number ranges from 1 to 1023.
CHAPTER 3 ND-70185 (E) Page 1 6 Revision 3. 0 SYSTEM CONFIGURA TION System Consi der ations Conditio n 5: Up to e ight (8) routes can b e assigned as alte rnate ro utes for a conne ct ion trunk.
ND-70185 (E) CHAPTER 3 Page 17 Revision 3. 0 SYSTEM CONFIGURA TION System C onsid erations Conditio n 9: The maxi mum of data l ink spe ed is “1.5 Mbp s.” Cond i tion 10: C o nne c tion Trunks (B ch) co nf or m to th e fo l lowing spec ificatio n s: • Exist i ng ext er nal trunk cannot be used as alt er nate routes for co nnection tr unks .
CHAPTER 3 ND-70185 (E) Page 1 8 Revision 3. 0 SYSTEM CONFIGURA TION System Consi der ations 3.2 Centra liz ed Billing - Fusion (P olling Method) This sect ion explains the cond itions of Central ized Billing - Fusion, focusing on when CCIS links are in- vo lved.
ND-70185 (E) CHAPTER 3 Page 19 Revision 3. 0 SYSTEM CONFIGURA TION System C onsid erations Figure 3-12 Centralized Billing - Fusion (2 /3) FCCS FCCS Fusion Network - Example 4 - Example 5 CCIS IMX IMX.
CHAPTER 3 ND-70185 (E) Page 2 0 Revision 3. 0 SYSTEM CONFIGURA TION System Consi der ations Figure 3-12 Centralized Billing - Fusion (3 /3) FCCS FCCS FCCS Fusion Network - Example 7 - Example 8 CCIS I.
ND-70185 (E) CHAPTER 3 Page 21 Revision 3. 0 SYSTEM CONFIGURA TION System C onsid erations 3.3 Cen t ra lized Ma nagement Re por t-Fusion T o collect f ault informa tion i n a Fusio n netw ork, th e Centr alize d Manag ement Repo rt-Fus ion is used.
CHAPTER 3 ND-70185 (E) Page 2 2 Revision 3. 0 SYSTEM CONFIGURA TION System Consi der ations The fo llowing ex plains service con ditions for the networ k including both FCCS and CCIS links.
ND-70185 (E) CHAPTER 3 Page 23 Revision 3. 0 SYSTEM CONFIGURA TION System C onsid erations Example: 2 When bot h FCCS and CCIS li nks ar e establ ished betwee n two nodes Figure 3-15 Central ized Management Report-Fusion (Example 2) Node A/B/C:Re fer to Example 1 on the previous page.
CHAPTER 3 ND-70185 (E) Page 2 4 Revision 3. 0 SYSTEM CONFIGURA TION System Consi der ations Example: 3 When a n od e is li nke d with L A N i nte rfac e Figure 3-16 Central ized Management Report-Fusion (Example 3) Node A: To send system messages t o Node E, a s sign Point Code of Node C (1) to ASYD, SYS 1, In dexes 184 and 1 85.
ND-70185 (E) CHAPTER 3 Page 25 Revision 3. 0 SYSTEM CONFIGURA TION System C onsid erations 3.4 Fusion Attendant/Desk Console 3.4.1 Operat or Call An o per ator c all ca n b e pl ace d fro m ea ch no d.
CHAPTER 3 ND-70185 (E) Page 2 6 Revision 3. 0 SYSTEM CONFIGURA TION System Consi der ations 3.4.2 Centra l Office Incomi ng Call (Ring Down) Each node can specify a t e rmi nating node for Ring Down ca ll s u sing the sys te m data. In this example, Node A and Node D specify Node C and No de E as the terminat ing node respect i ve ly .
ND-70185 (E) CHAPTER 3 Page 27 Revision 3. 0 SYSTEM CONFIGURA TION System C onsid erations 3.4.3 Day/Night Chang e Day/Night informat ion i s transfe rred from an ATTCON/ DESKCON t o predetermined nodes. In th i s example, Node C speci fies Node A and Node B as des tination nod es by assignin g FPCs 1 and 2 in Indexes 7 04-735.
CHAPTER 3 ND-70185 (E) Page 2 8 Revision 3. 0 This page is for your notes..
ND-70185 (E) CHAPTER 4 Page 29 Revision 3. 0 CHAPTER 4 I NST ALLA TION This chapte r covers the insta ll at i on of the Fus ion sys t em. The following topi cs ar e covered: • Ho w to set switches o.
CHAPTER 4 ND-70185 (E) Page 3 0 Revision 3. 0 INST ALLA TION Anti-S tatic Cauti on Figure 4- 2 shows the ant i- static kit tha t is provide d. Use the kit as shown below when handling stati c-se nsitive components such as circui t card s and cables.
ND-70185 (E) CHAPTER 4 Page 31 Revision 3. 0 INST ALLA TION Anti-Stat ic Caut io n 1.1 Circuit Cards Required Depending on t he syst em type, the follo wing circuit car ds are required to inst all the.
CHAPTER 4 ND-70185 (E) Page 3 2 Revision 3. 0 INST ALLA TION Key Setting on Cir c uit Car ds 2. Ke y Setting on Ci rcuit Card s 2.1 P A -M96 (HUB) Set the SEL switch on the HUB ( PA-M96) card(s), after refer ring to Figure 4- 4 an d Ta b l e 4 - 1 .
ND-70185 (E) CHAPTER 4 Page 33 Revision 3. 0 INST ALLA TION Key Setting on Circ uit Car ds 2. 2 P A- FCHA ( FCH) Set the swit ches on the FCH (P A-FCHA) car d(s) as sho wn bel o w. This car d has DIP switches, whose key setti ngs de termine the t ime sl ots o f the Fusion link.
CHAPTER 4 ND-70185 (E) Page 3 4 Revision 3. 0 INST ALLA TION Key Setting on Cir c uit Car ds Note 1: 64Kbps is used for T1 or E1 inter fac e . 56Kbps is used for T1 inter fac e with bit st eal i ng. 48Kbps is used for T1 inter fac e with both bit stealing and Ze ro Code Suppress io n ( o r Bi t 7 Stuffin g ) .
ND-70185 (E) CHAPTER 4 Page 35 Revision 3. 0 INST ALLA TION Key Setting on Circ uit Car ds 2.3 P A-24DTR (DTI) Ther e are two t ype s of the P A-24 DTR (DTI ) ca rd as s hown be low. Refe r to Figure 4-6 and Table 4- 4 to s et each switch to the proper pos it ions.
CHAPTER 4 ND-70185 (E) Page 3 6 Revision 3. 0 INST ALLA TION Key Setting on Cir c uit Car ds SW4D 1 ON Trans mission Signal A Logic: Neg ativ e OFF × T ransm ission Signal A Logic: Pos itiv e 2 ON Re.
ND-70185 (E) CHAPTER 4 Page 37 Revision 3. 0 INST ALLA TION Key Setting on Circ uit Car ds SW39 1 ON OFF × 2 ON × OFF 3 ON × OFF 4 ON × OFF 5 ON × OFF 6 ON OFF × 7 ON × OFF 8 ON OFF × T able 4.
CHAPTER 4 ND-70185 (E) Page 3 8 Revision 3. 0 INST ALLA TION Key Setting on Cir c uit Car ds SW6C 1O N × Fixed 2O N × Fixed 3O N × Fixed 4O N × Fixed 5O N × Fixed 6O N × Fixed 7O N × Fixed 8O N.
ND-70185 (E) CHAPTER 4 Page 39 Revision 3. 0 INST ALLA TION Key Setting on Circ uit Car ds Note: This switc h setting is app licable for a syste m whic h adopts Ass ociated Chann el Inter of f ice Signal ling (A CIS ).
CHAPTER 4 ND-70185 (E) Page 4 0 Revision 3. 0 INST ALLA TION Mounting C ircuit Car ds in PI M 3. Mounting Circui t Cards in PIM 3.1 Mounting HUB (P A-M96) i n a PIM Mount the HU B (P A-M96) card in an appropria te slot of a PI M as sho wn belo w . When the MA T is con- nected via a HUB card, be sure to use a dedicated HUB for the Fus ion link.
ND-70185 (E) CHAPTER 4 Page 41 Revision 3. 0 INST ALLA TION Moun ting Ci rcuit C ards in PIM 3.2 Mounting FCH ( PA-FCH A) and DTI ( P A-24DTR) Cards Mount the FCH (P A-FCHA) and the DTI ( PA-24DTR) card in appropriate slots in a P IM. Mou nt the t wo cards i n adjacent sl ots since the se cards must be connected on t he front connec tors.
CHAPTER 4 ND-70185 (E) Page 4 2 Revision 3. 0 INST ALLA TION Connectin g Cable s 4. Connecting Cables 4.1 Connecting DTI-FCH Fro nt Cables Connect the furni shed fro nt cable to the conn ector s on the DTI and FCH car ds. Use DTI and CN2 connec- tors on th e FCH and DTI cards respec ti vel y .
ND-70185 (E) CHAPTER 4 Page 43 Revision 3. 0 INST ALLA TION Connecti ng Cabl es Since a maximum of f i v e Handler circ uits can be used, f iv e FCH cards can be cascaded.
CHAPTER 4 ND-70185 (E) Page 4 4 Revision 3. 0 INST ALLA TION Connectin g Cable s 4.2 Co n necting 10 BASE-T Cables Figure 4- 11 sho ws sampl e ca ble connections, where HUB ( P A-M96) cards are p ro vided in a dua l configu - ration and the FCH (P A-FCHA) card is located in PI M 1 (1-IMG sys tem/IMG0).
ND-70185 (E) CHAPTER 4 Page 45 Revision 3. 0 INST ALLA TION Connecti ng Cabl es 4.3 10 B ASE-T Connection Pr ocedure The patt ern for 10 B ASE-T cable connecti ons may var y , dependi ng on the sy stem confi guration (such a s number of IMG stacks or the mountin g location /number o f the FCH/HUB car ds, e tc.
CHAPTER 4 ND-70185 (E) Page 4 6 Revision 3. 0 INST ALLA TION Connectin g Cable s 4.3.3 When not usin g the c able unit SR1201 ETIF C AU-n When your sy stem doesn’ t u se the cab le unit c lassif ied as SR1201 ETIF CA U-n, per form the 1 0 B ASE- T connect ions as inst ructed bel ow: 1.
ND-70185 (E) CHAPTER 4 Page 47 Revision 3. 0 INST ALLA TION Connecti ng Cabl es When dual LANIs ar e used in both Slot 00 and 03 of CPR#0/CPR#1, be sure to us e at least two HUB cards as se parate 10 B ASE-T connec tion terminals.
CHAPTER 4 ND-70185 (E) Page 4 8 Revision 3. 0 INST ALLA TION Connectin g Cable s When dual FCH i s provided for the HUB dedicat ed to eac h internal LANI ca rd (LANI-A: in Slot 00 of each CPR), conn ect FCH#0 to HUB#0 and FCH#1 to HUB#1.
ND-70185 (E) CHAPTER 4 Page 49 Revision 3. 0 INST ALLA TION Connecti ng Cabl es Figure 4- 13 shows some t ypical ex amples, where 10 BASE- T cables ar e connecte d to the FCH car d(s) mounte d in PIM0 of 1-I MG system, under the followi ng conditi ons: Note 1: Cables Contai ned in e ach c able unit ar e as follows.
CHAPTER 4 ND-70185 (E) Page 5 0 Revision 3. 0 INST ALLA TION Connectin g Cable s Figure 4-13 Examples of Ethernet Cable Connection-FCH in PI M0 (1-IM G System) (2/2) ATTENTION Contents Static Sensitiv.
ND-70185 (E) CHAPTER 4 Page 51 Revision 3. 0 INST ALLA TION Connecti ng Cabl es Figure 4- 14 shows some t ypical ex amples, where 10 BASE- T cables ar e connecte d to the FCH car d(s) mounte d in PIM1 of 1-I MG system, under the followi ng conditi ons: Note 1: Cables containe d in each cable unit ar e as follows.
CHAPTER 4 ND-70185 (E) Page 5 2 Revision 3. 0 INST ALLA TION Connectin g Cable s Figure 4- 15 shows some t ypical ex amples, where 10 BASE- T cables ar e connecte d to the FCH car d(s) mounte d in PIM2 of 1-I MG system, under the followi ng conditi ons: Note 1: Cables containe d in each cable unit ar e as follows.
ND-70185 (E) CHAPTER 4 Page 53 Revision 3. 0 INST ALLA TION Connecti ng Cabl es Figure 4-15 Examples of Ethernet Cable Connection-FCH in PI M2 (1-IM G System) (2/2) ATTENTI O N Content s Stat ic Sensi.
CHAPTER 4 ND-70185 (E) Page 5 4 Revision 3. 0 INST ALLA TION Connectin g Cable s Figure 4- 16 shows some t ypical ex amples, where 10 BASE- T cables ar e connecte d to the FCH car d(s) mounte d in PIM3 of 1-I MG system, under the followi ng conditi ons: Note 1: Cables containe d in each cable unit ar e as follows.
ND-70185 (E) CHAPTER 4 Page 55 Revision 3. 0 INST ALLA TION Connecti ng Cabl es Figure 4-16 Examples of Ethernet Cable Connection-FCH in PI M3 (1-IM G System) (2/2) ATTENTI ON Cont ent s St at i c Sen.
CHAPTER 4 ND-70185 (E) Page 5 6 Revision 3. 0 This page is for your notes..
ND-70185 (E) CHAPTER 5 Page 57 Revision 3. 0 CHAPTER 5 D A T A PR OGRAMMI NG This cha pt er ex p lai ns h ow to se t Fusi o n Net w ork da ta, u s i ng t he fol l o w ing data categories: • Syste m .
CHAPTER 5 ND-70185 (E) Page 5 8 Revision 3. 0 DA T A PROGRAMMIN G Network Da ta Progr amming S ummary 1. Network Data Pr ogramming Summar y This sect io n ex p lain s a su m m a ry of the data pro g ra m mi ng of Fu s ion s yst em s .
ND-70185 (E) CHAPTER 5 Page 59 Revision 3. 0 DA T A PROGRAMMING Network Data Pr og ra mming Sum mary 1.2 Upgrading a CCIS Networ k T o install th e Fusion syste m to an e xisting CCIS ne twork, the o ver all programmin g procedure is as follo ws: 1.2.
CHAPTER 5 ND-70185 (E) Page 6 0 Revision 3. 0 DA T A PROGRAMMIN G Network Da ta Progr amming S ummary 1.3 F u sio n Link Data • Assign the Fusion Link data using the foll owing com mands: Fusion wit.
ND-70185 (E) CHAPTER 5 Page 61 Revision 3. 0 DA T A PROGRAMMING Network Data Pr og ra mming Sum mary Figure 5 - 3 sho ws ho w to upgrade an existing CCIS network, focusin g on t he Num bering Plan. The example data setti ng assumes the existing ne twork uses this particular numberi ng.
CHAPTER 5 ND-70185 (E) Page 6 2 Revision 3. 0 DA T A PROGRAMMIN G Assig n ment of Syst em Data 2. Assignment of System Data STEP 1: ASYDL and ASYDN Assi gn the numb er of data m emo ry bl ocks f or the N etwo rk D ata M emo ry (ND M) an d the L ocal D ata Memory (LDM).
ND-70185 (E) CHAPTER 5 Page 63 Revision 3. 0 DA T A PROGRAMMING Assignm ent of System Data STEP 2: ASYDL Assign the se lf-Fusio n Point Code (self -FPC) at each node . FPC ranges from 1 to 253. Use the ASY- DL command. (In dex 512 b0-b 7) • Inde x 512 self-F usion Point Code Assign a u nique FPC for each node.
CHAPTER 5 ND-70185 (E) Page 6 4 Revision 3. 0 DA T A PROGRAMMIN G Assig n ment of Syst em Data Index 8 00 For A S YD L b0 : 0/ 1 = ALGNL, ALGSL on a UGN (TN) basis/- b1 : 0/1 = ASPAL on a TN basis/- b.
ND-70185 (E) CHAPTER 5 Page 65 Revision 3. 0 DA T A PROGRAMMING Assignm ent of FPC and MG and UNIT into Netwo rk 3. Assignment of FPC and MG and UNIT into Netw ork 3.1 AFMU Assign t he module a c commodat ion data by gi ving Module Group Number and Unit Number on an FPC basis.
CHAPTER 5 ND-70185 (E) Page 6 6 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of Logic al RT in Network DM (ND M) 4. Assignment of Logical RT in Netw ork DM (NDM) 4.1 ALR TN/ARTKN This command i s used to assign Logi cal Route Number s to all e xternal trunks used on a Fusion netw ork.
ND-70185 (E) CHAPTER 5 Page 67 Revision 3. 0 DA T A PROGRAMMING Assignme nt of Numberin g Data fo r T elep hone Nu mbers The ALRTN command d isplay should loo k similar to th e following: Figure 5-12 ALRTN Command D ispla y 5. Assignment of Numbering Data f or T elephone Numbers STEP 1: ANPDN Make a Tel ephone Numbe ring plan on th e networ k.
CHAPTER 5 ND-70185 (E) Page 6 8 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of Number ing Data fo r T elep hone Num bers STEP 2: ANPDN Assign P re-translation Data for the Telephone Numbers planned in S tep 1 using t he ANPDN com- mand at NCN.
ND-70185 (E) CHAPTER 5 Page 69 Revision 3. 0 DA T A PROGRAMMING Assignme nt of Numberin g Data fo r T elep hone Nu mbers STEP 3: ASPAN Assign sp ecial access c ode data for the Telephon e Numbers usi ng the ASPAN co m mand. SRV=TELN is the da ta for Telephone Numbers.
CHAPTER 5 ND-70185 (E) Page 7 0 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of T elep hone Nu mbers 6. Assignment of T elephone Numbers This sect ion explains how to program Telepho ne Numbers.
ND-70185 (E) CHAPTER 5 Page 71 Revision 3. 0 DA T A PROGRAMMING Assignmen t of T elep hone Nu mbers Figure 5-19 ALG SN Co mmand Display (example) UGN TELN WRT? ALGSN (Assignment of Telephone Station D.
CHAPTER 5 ND-70185 (E) Page 7 2 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of T elep hone Nu mbers 6.1 Assignment of C onnection Route/T runk Data STEP 1: ACRD Using the ACRD command , assign the connectio n route data of Fusion li nk. The data must be assigne d for both B-channel and D-channel .
ND-70185 (E) CHAPTER 5 Page 73 Revision 3. 0 DA T A PROGRAMMING Assignmen t of T elep hone Nu mbers T able 5-1 Rout e Class Dat a Assignmen t CDN Node A Node B Description type B-channel D-c hannel B-.
CHAPTER 5 ND-70185 (E) Page 7 4 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of T elep hone Nu mbers CDN 1: T runk Kind 0-2: - 3: Bothw ay Trunk CDN 2: TCL (Tr unk Class) 0-3: - 4: Fusio n T runk 5-3.
ND-70185 (E) CHAPTER 5 Page 75 Revision 3. 0 DA T A PROGRAMMING Assignmen t of T elep hone Nu mbers CDN 10: FPEG (Fusion T runk Pe g Count) Assign 0. CDN 11: TC (T imer Class) 0: - 1: 1 sec 2: 2 sec 3.
CHAPTER 5 ND-70185 (E) Page 7 6 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of T elep hone Nu mbers STEP 2: ACTK Assign t he conne ction trunk d ata of both B-channel and D-channel using the ACTK command . As- sign the Connection Equ ipment Number (C_ LENS) referr ing to Fi gure 5-22 t hrough Figur e 5-25 .
ND-70185 (E) CHAPTER 5 Page 77 Revision 3. 0 DA T A PROGRAMMING Assignmen t of T elep hone Nu mbers T able 5-2 Data Prog ramming Sheet for Regular Density Slot C_RT (1-1023) C_T K(1-4 095) C_LENS Time.
CHAPTER 5 ND-70185 (E) Page 7 8 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of T elep hone Nu mbers 6.1.2 Whe n FCH is Mounte d in a High Density Sl ot If the FCH is to b e m oun te d i n t he Hi g h De nsi ty S l ot, th e conne ct io n tr unk d ata shoul d be as si gn ed as sho wn in the f igures belo w .
ND-70185 (E) CHAPTER 5 Page 79 Revision 3. 0 DA T A PROGRAMMING Assignmen t of T elep hone Nu mbers When the DTI cards is mo unted in a double d e nsit y slot, the C_LEN da ta for the FCH and DTI card s are as follo ws.
CHAPTER 5 ND-70185 (E) Page 8 0 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of T elep hone Nu mbers T able 5-3 Data Programming Sheet for High Density Sl ot C_RT (1-1023) C_TK (1-4095) C_LE NS Time .
ND-70185 (E) CHAPTER 5 Page 81 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data STEP 4: MBCT Unbusy the connection t runk data ass igned in the previous ste p using MBCT (Make Busy of Connec - tion Tr unk) command . This step is re quired f or both B-channel and D-channel trunk .
CHAPTER 5 ND-70185 (E) Page 8 2 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of FCH Related D ata Figure 5- 29 shows a sample dat a assignment when FCH car ds are loca ted in the PIM 0 slo t 4 and PIM 2 slot 11.
ND-70185 (E) CHAPTER 5 Page 83 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data STEP 2: AFRT (Fusion with FCH only) Assign co nnection route number s as shown below using the AFRT command. Figure 5-2 9 A F RT Sample D ata Sheet The AFRT comma nd display should look simi lar to Figure 5-3 0 .
CHAPTER 5 ND-70185 (E) Page 8 4 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of FCH Related D ata STEP 3: AFPC Assign FCH rou ting data usi ng the AFPC command. A maxi mum of 8 connect ion route s and FCHN/ FPCN can be as signed on a node basi s. FCHN is used for Fusion System with FCH.
ND-70185 (E) CHAPTER 5 Page 85 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data The tab le in Figu re 5- 33 shows a sample data she et for Node A on a Fusion ne twork wit h FCH. Assign the dat a for all nodes inc luding the no des which are not dire ctly connected on th e network.
CHAPTER 5 ND-70185 (E) Page 8 6 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of FCH Related D ata STEP 4: ACAN Assign t he Fusi on Co nnecti on Ind ex Code (FCIC) a nd t he LENs on an ad jacen t FP C basis . Figur e 5- 34 show s a sa mple d ata sh eet f or No de A.
ND-70185 (E) CHAPTER 5 Page 87 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data 7.1 Ass ig nm ent of Access Code for T andem Connec tio n via FCCS - A CIS F or Release 3 or la ter sof twa re, tandem connection vi a FCCS - A CI S link can be es tabli shed.
CHAPTER 5 ND-70185 (E) Page 8 8 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of FCH Related D ata STEP 1: ANPDN/ANPDL Not e Assign t he first digit of th e OGC access code. Wh en t he a ccess code i s co mmon to all nodes, use th e ANPDN command. When the access co de is ass igned for each no d e, use the ANPDL command.
ND-70185 (E) CHAPTER 5 Page 89 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data 7.1.2 OGC A A procedur e for assignin g OGCA access code is e xplaine d using the f o llowin g example. Figure 5-37 Example of OGCA STEP 1: ANPDN/ANPDL Not e Assign t he first dig it of the OGCA acc ess code.
CHAPTER 5 ND-70185 (E) Page 9 0 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of FCH Related D ata STEP 3: ANNDL/AMND Assign the nec essar y numb er of di gits using th e ANNDL or the AMND comm and d epending on the route da ta. • When the AR TD command OSGS is 2 ( Second Dial T one), use the ANNDL ( Necessary Dig its Data ) com mand.
ND-70185 (E) CHAPTER 5 Page 91 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data STEP 1: ANPDN/ANPDL Not e Assign th e first digit of the LCR/LCRS access co de. When the acce ss code is common to a ll nodes, use the ANPDN command. When the a ccess code is assigned for each node, u se the ANPDL com- mand.
CHAPTER 5 ND-70185 (E) Page 9 2 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of FCH Related D ata STEP 5: ARTD/ARTDN Using ARTD, ass ign th e followi ng CDN data for the du m my route n umber. Note 1 CDN 6 (TCL)=1 or 4 (depending on requiremen t) CDN 7 (L/T)=1 CDN 13 (AC)=1 The ot her CDNs may be l eft defaul t (data 0) for t he dummy r oute.
ND-70185 (E) CHAPTER 5 Page 93 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data 7.2 Dat a Assignm ent for 52M-S DH Interfa ce This sect ion e xplains the Fusion Connect ion with 52M-SDH in terf ace, which i s a vailabl e for Release 4 or later s oft ware.
CHAPTER 5 ND-70185 (E) Page 9 4 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of FCH Related D ata Specifi cations for the SDH data set ting are de scribed below .
ND-70185 (E) CHAPTER 5 Page 95 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data • Connect ion Link (fo r Data) C_RT: 11 TCL=4 LSG=13 STEP 3: ACTK Assign t he Connecti on Trunk data for B- ch and D-ch.
CHAPTER 5 ND-70185 (E) Page 9 6 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of FCH Related D ata STEP 8: AFPC Assign t he FCCS routin g data. FPC: 1 (FP C of the adjacent node )FCCH: 1 (wit h FCCH) CRT: 10 FCHN: 2 STEP 9: ACAN Assign t he CIC number to the c onnection trunk.
ND-70185 (E) CHAPTER 5 Page 97 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data 7.3 F CCS Lin k via Internet/I ntrane t The s ys te m c an excha ng e F CC S d ata v ia the Inte rn e t/ Intr a ne t.
CHAPTER 5 ND-70185 (E) Page 9 8 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of FCH Related D ata STEP 1: ACRD Assign Rou t e Class Data of Speech Rou t e, FCH, FGH r outes, r espectiv ely. A sampl e data as signment is shown b e low. See 6.1 Assignme nt of Connec tion Route/Trunk Da ta for more detailed info rmation.
ND-70185 (E) CHAPTER 5 Page 99 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data STEP 2: ACTK Assign t he connect ion trunk data of DTI, FCH, a nd FGH cards, us ing the ACTK c ommand. When assigni ng FCH, FGH tru nk data, eig ht trunks must b e set.
CHAPTER 5 ND-70185 (E) Page 100 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of FCH Related D ata STEP 3: AFCH Assign FCH number on an FCH cir cuit ca rd basis . In the following example , FCHN=1 is assigne d for the FCH circ uit card. For the FGH card, F CHN ass ign m ent is not nec ess ary.
ND-70185 (E) CHAPTER 5 Page 101 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data STEP 5: AFPC Assign i nternal LAN routin g data. FPC (Fusion Point Code): As sign FPC number (1 -253) of the Dest ination Nod e. FCCH: Assign "1".
CHAPTER 5 ND-70185 (E) Page 102 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of FCH Related D ata STEP 6: AETH Assign t he external rout er routing d ata. FPC (Fusion Point Code): As sign FPC number (1 -253) of the Dest ination Nod e. USE_GATE: Assign "1 (= use Gateway)".
ND-70185 (E) CHAPTER 5 Page 103 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data STEP 7: ACAN Assign t he Fusion Connectio n Index Code (FCIC) for th e Next Node. FPC (Fusion Poi nt Code): Assign FPC number of the Next Node (Node to be passed to).
CHAPTER 5 ND-70185 (E) Page 104 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of FCH Related D ata 7.3.2 FCCS Net working over IP This feat ure all ows the syst e m to e xchange both speech and FCCS signa ling o ver Intern et/Intranet . To establ ish/r eleas e a cal l, Q-sig is u sed bet ween the sys tem and t he rou ter .
ND-70185 (E) CHAPTER 5 Page 105 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data STEP 1: ACRD Assign Rou t e Class Data of Speech Rou t e, FCH, FGH r outes, r espectiv ely.
CHAPTER 5 ND-70185 (E) Page 106 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of FCH Related D ata STEP 3: MBCT Unbusy th e c onnection trun k da ta assigned i n t he previous step , by using the MBCT command. This is req uire d for FCH , F GH t run ks a s well as spe e ch c ha n nel s.
ND-70185 (E) CHAPTER 5 Page 107 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data STEP 5: AETH Assign t he FCCS routing data , when external rout er is u sed by spec ifying IP add ress. FPC (Fusion Point Code): As sign FPC number (1 - 253) of t he Dest ination N ode.
CHAPTER 5 ND-70185 (E) Page 108 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of FCH Related D ata STEP 6: ACAN Assign t he Fusion Connectio n Index Code (FCIC) for th e Next Node. FPC (Fusion Point Code): As sign FPC number of the Sel f-node. FCIC (Fusi on Connection Index Code): A ssign Fu sion CIC of the Self-node.
ND-70185 (E) CHAPTER 5 Page 109 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data STEP 8: AGIP Assign IP addresses of FGH ca rd and its con nected ro uter. FCHEN (FCH Equipment Numbe r) : Assign LV0 data of FGH LEN s. FGH_IP (FGH IP Address) : Assign IP address o f the FGH car d.
CHAPTER 5 ND-70185 (E) Page 110 Revision 3. 0 DA T A PROGRAMMIN G Assignmen t of FCH Related D ata STEP 9: AFIP Assign th e FCCS Networkin g over IP data for controllin g Speech Channels between PBX and router. FCHN (FCH Number): Assign FCHN specifi ed in STEP 4.
ND-70185 (E) CHAPTER 5 Page 111 Revision 3. 0 DA T A PROGRAMMING Assign ment of FCH Relat ed Data 7.4 Flexible Routing - FCCS A Fusion tr unk call can b e routed vi a "non-Fusion" tr unk (C.O. or T ie Line), i f the Fusion trunks are all bu sy or Data Link F ailure occurs at the FCH card, etc .
CHAPTER 5 ND-70185 (E) Page 112 Revision 3. 0 DA T A PROGRAMMIN G Office Data Shee ts 8. Office Data Sheets 8.1 Dat a Sheet for AFMUPL FUSION POINT CODE (FPC) 1-25 3 MODULE GR OUP (MG) 0/1 UNIT 0-3 RE.
ND-70185 (E) CHAPTER 5 Page 113 Revision 3. 0 DA T A PROGRAMMING Office Data Sheets 8.2 Dat a Sheet for ALRTN LOGICAL R OUTE NUMBER (LGRT) 1-89 9 FUSION PO INT CODE (FPC) 1-253 EXTERNAL R O UTE NUMBER.
CHAPTER 5 ND-70185 (E) Page 114 Revision 3. 0 DA T A PROGRAMMIN G Office Data Shee ts 8.3 Data S heet for ANPD/ANPDL/ANDP N TENANT NUMBER (TN) 1ST D IGI T (1ST DC) CONNECTION ST A TUS INDEX (CI) BUSY .
ND-70185 (E) CHAPTER 5 Page 115 Revision 3. 0 DA T A PROGRAMMING Office Data Sheets 8.4 Dat a Sheet for ASP A/ASP AL TENANT NUMBER (TN) A CCESS CODE (A CC) MAX.
CHAPTER 5 ND-70185 (E) Page 116 Revision 3. 0 DA T A PROGRAMMIN G Office Data Shee ts 8.5 Dat a Sheet for ALGNL USER GR OUP NUMBER (UGN) LOGICAL ST A T ION NUMBE R (LSTN) MAX.
ND-70185 (E) CHAPTER 5 Page 117 Revision 3. 0 DA T A PROGRAMMING Office Data Sheets 8.6 Dat a Sheet for ALGSL (TYPE1 ) TYPE UGN LSTN LENS REMARKS 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 .
CHAPTER 5 ND-70185 (E) Page 118 Revision 3. 0 DA T A PROGRAMMIN G Office Data Shee ts 8.7 Dat a Sheet for ALGSL (TYPE2 ) TYPE UGN LSTN TN LENS REMARKS 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 2.
ND-70185 (E) CHAPTER 5 Page 119 Revision 3. 0 DA T A PROGRAMMING Office Data Sheets 8.8 Dat a Sheet for ASDT TENANT NUMBER (TN) ST A TION NUMBER (STN) LINE EQ UIPMENT NUMBER (LEN S) TELEPHONE EQUIPM E.
CHAPTER 5 ND-70185 (E) Page 120 Revision 3. 0 DA T A PROGRAMMIN G Office Data Shee ts 8.9 Dat a Sheet for A CRD CDN CONNECTION RT No. (C_RT) 1-1023 FUNCTION (FUNC) 1 TF - T ype of T runk 0-2 = - 3 = B.
ND-70185 (E) CHAPTER 5 Page 121 Revision 3. 0 DA T A PROGRAMMING Office Data Sheets 10 FPEG - Fusion-PEG (Fix ed “0”) 0 = Nothing of FUSION-PEG 1 = Exist of FUSION-PEG 000000 11 TC - Ti mer Clas s (Fixed “0”) 1 = 1 sec. 2 = 2 sec. 3 = 8 sec. 4 = 30 sec.
CHAPTER 5 ND-70185 (E) Page 122 Revision 3. 0 DA T A PROGRAMMIN G Office Data Shee ts 8.10 Data S heet for ACTK CONNECTION ROUTE NUMBER (C_R T) 1-1023 CONNECTION TRUNK NUMBER (C_ TK) 1-40 95 CONNECTIO.
ND-70185 (E) CHAPTER 5 Page 123 Revision 3. 0 DA T A PROGRAMMING Office Data Sheets 8.11 Data S heet for AFCH FCCH NUM BER (FCHN) 1-255 LENS OF FCCH (FCHEN) REMAR KS MG U G L 10 20 30 40 50 60 70 80 9.
CHAPTER 5 ND-70185 (E) Page 124 Revision 3. 0 DA T A PROGRAMMIN G Office Data Shee ts 34 0 35 0 36 0 37 0 38 0 39 0 40 0 41 0 42 0 43 0 FCCH NUM BER (FCHN) 1-255 LENS OF FCCH (FCHEN) REMAR KS MG U G L.
ND-70185 (E) CHAPTER 5 Page 125 Revision 3. 0 DA T A PROGRAMMING Office Data Sheets 8.12 Data S heet for AF PC FUSION POINT CODE (FPC) 1-253 FCCH USE OR NO T USE (FCCH) 0/1 123456 78 CONNECTION ROUTE .
CHAPTER 5 ND-70185 (E) Page 126 Revision 3. 0 DA T A PROGRAMMIN G Office Data Shee ts FUSION POINT CODE (FPC) 1-253 FCCH USE OR NO T USE (FCCH) 0/1 123456 78 CONNECTION ROUTE (C_RT) 1-10 23 FCCH NUMBE.
ND-70185 (E) CHAPTER 5 Page 127 Revision 3. 0 DA T A PROGRAMMING Office Data Sheets 8.13 Data S heet for A CAN FUSION POINT CODE (FPC) 1-253 FUSION CIC NUMBER (FCIC) 1-40 95 CONNECTION EQUIPMENT NUM B.
CHAPTER 5 ND-70185 (E) Page 128 Revision 3. 0 DA T A PROGRAMMIN G Office Data Shee ts 8.14 Data S heet for AFRT FCCH NUMBER (FCHN) 1-255 CONNECTION ROUTE (C_R T) 1-1023 12345678.
ND-70185 (E) CHAPTER 5 Page 129 Revision 3. 0 DA T A PROGRAMMING Office Data Sheets 8.15 Data S heet for AET H DESTINA TION FPC (FP C) 1-25 3 GA TEW A Y USING FLA G (USE_GA TE) 0/1 FCCH NUMBER (FCHN) .
CHAPTER 5 ND-70185 (E) Page 130 Revision 3. 0 DA T A PROGRAMMIN G Office Data Shee ts 8.16 Data S heet for A G IP LINE EQ UIPME N T NUMBER OF FCCH (FCH EN) FGH IP ADDRESS (FGH _IP) IP ADDRESS FOR DE F.
ND-70185 (E) CHAPTER 5 Page 131 Revision 3. 0 DA T A PROGRAMMING Office Data Sheets 8.17 Data S heet for AFIP FCH NUMBER (FCHN) LINE EQUIPMENT NUMBER OF FGH (FGHEN) LIN E EQUIPM ENT NUMBER OF QSIG-PRIME Bch (LENS) ROUTER A CCESS NUMBER (RT_A CC) Max.
CHAPTER 5 ND-70185 (E) Page 132 Revision 3. 0 DA T A PROGRAMMIN G Office Data Shee ts 8.18 Data S heet for AFRFL TN FPC (1-253) AC C MAX. 24 digits.
ND-70185 (E) CHAPTER 6 Page 133 Revision 3. 0 CHAPTER 6 POST INST ALLA TION TEST This chap ter cove rs ho w to per form inst alla tion tes ts foc usi ng o n the Fusi on Call Con trol S igna l (d enot ed in the remainde r of th is manual as FCCS) conne ctions, after hard ware installa tion and data assi gnment.
CHAPTER 6 ND-70185 (E) Page 134 Revision 3. 0 POST INST ALLA TION TEST Repair P rocedur e When LED I ndica tes Abnor mality 1.1 How to check L YR LE D 1. Conf irm the L YR LED lights green on the front edge of t he FCH (P A-FCHA) circuit card. (See “LED Indic a tion (A )” in Figure 6-2 .
ND-70185 (E) CHAPTER 6 Page 135 Revision 3. 0 POST INST ALLA TION TEST Repair Proc edu re When LED Indicates A bno rm ality • FCH (P A-FCHA) swit ch setting Make sure th at th e foll owing keys are .
CHAPTER 6 ND-70185 (E) Page 136 Revision 3. 0 POST INST ALLA TION TEST Repair P rocedur e When LED I ndica tes Abnor mality All 24 B-c han n e ls se nt fr om th e TSW are l oop e d bac k to the TSW at In t erfac e on the card . At this time, the adjacent node dete cts AIS signals.
ND-70185 (E) CHAPTER 6 Page 137 Revision 3. 0 POST INST ALLA TION TEST Repair Proc edu re When LED Indicates A bno rm ality 2.3 T est Procedu re STEP 1: Set the MODE s w itch to 9 (Fusion Link Test) f.
CHAPTER 6 ND-70185 (E) Page 138 Revision 3. 0 POST INST ALLA TION TEST FCCS Network Connection T e st Figure 6-7 Fu sion Li nk -Test Resu lts STEP 4: Return Mode to 8 (s tandard s etting) when the test is complete. STEP 5: Initialize the FCH (PA-FCHA) card using the MB switch.
ND-70185 (E) CHAPTER 6 Page 139 Revision 3. 0 POST INST ALLA TION TEST FCCS Networ k Conn ection T est STEP 4: The call te rmi nates on STN B. STEP 5: Confirm t he speech c ondition is suf ficient (no no ise, not on e -way speec h, etc.). STEP 6: Replace the handset of STN A.
CHAPTER 6 ND-70185 (E) Page 140 Revision 3. 0 POST INST ALLA TION TEST FCCS Network Connection T e st 3.2 A TTCO N C onnectio n T est (via FCCS ) Perform t he A TTCON connect ion test , using th e follo wing proced ure. 3.2.1 A TTCON Call Originatio n Test STEP 1: Dial the ope ra tor access code (normally “0”) , f rom STN A in Node A.
ND-70185 (E) CHAPTER 6 Page 141 Revision 3. 0 POST INST ALLA TION TEST FCCS Networ k Conn ection T est 3.3 Line (LC, E LC, DLC Card) Connection T est (via F CCS) Perform the Line (LC, ELC, DLC Card) connection test, following the p roced ure s listed be l ow.
CHAPTER 6 ND-70185 (E) Page 142 Revision 3. 0 POST INST ALLA TION TEST FCCS Network Connection T e st 3.4 3- par ty Co nferenc e T runk Func tion T est (via FCCS) Perform the 3-pa rty conference tr unk fun ction test, follo wing the proc edu res li sted belo w .
ND-70185 (E) CHAPTER 6 Page 143 Revision 3. 0 POST INST ALLA TION TEST Fusi on and N on-Fusio n Connecti on T ests 3.5.1 Primar y Route T r unk T est STEP 1: Using the MBCT command, make busy all trunks in the pr im ary rout e excep t the trunk to be tested.
CHAPTER 6 ND-70185 (E) Page 144 Revision 3. 0 POST INST ALLA TION TEST Fusion and Non-Fu si on Conn ec tio n T es ts 4.1 When Seizing a T runk fr om a Station STEP 1: Using the MAT command, make busy all trunks in the route except the trunk to be tested.
ND-70185 (E) CHAPTER 6 Page 145 Revision 3. 0 POST INST ALLA TION TEST SDT Ca rd Loo pba ck T est 5. SDT Card Loopback Test The patt erns for loo pback test , which can b e set by t he SDT card, ar e as fol lows: 1. Local Loop back Loopback t ests are per formed only on th e SDT card at the self -node.
CHAPTER 6 ND-70185 (E) Page 146 Revision 3. 0 POST INST ALLA TION TEST SDT Card Loopback Test STEP 2: Make sure t hat the “LPB” lamp on the PA-SDTA car d, or th e “SYCxx” l a mp o n the PA-SDTB card light s ste ady -gr een .
ND-70185 (E) CHAPTER 7 Page 147 Revision 3. 0 CHAPTER 7 TROUBLESHOO TING This cha pter explains the Fusion-rel ated system messag es that may be displaye d, togethe r wi th proce dures on how to repair the indicated failure. If the message i s dis played, f ollow the proce dure described in each s ystem message.
CHAPTER 7 ND-70185 (E) Page 148 Revision 3. 0 TROUBLESHOOTING List of Fusio n-rela ted Sy stem M essages Figure 7- 1 shows a sample syst em config uration.
ND-70185 (E) CHAPTER 7 Page 149 Revision 3. 0 TROUBLESHOOTING 3-B PM C- le ve l Infin ite Loo p (Pe rm ane nt) 2. 3-B PM C-level Infin ite Loop ( Permanent) This message is displa yed when a C-lev e l program abnormal sta te has been de tected as permanent.
CHAPTER 7 ND-70185 (E) Page 150 Revision 3. 0 TROUBLESHOOTING 3-B PM C-level Inf inite Loop (Per m anen t) Figure 7-4 How to Replace the FCH (PA-FCHA) Card [How to Replace FCH card] 4 C 0 2 6 A E 8 MN.
ND-70185 (E) CHAPTER 7 Page 151 Revision 3. 0 TROUBLESHOOTING 3-C P M C-lev el Infi nite Loop (T empora ry) 3. 3-C PM C-level Infinite Loop ( Temporary) This message is displayed when the C-le vel pro gram has been detec ted as abnor mal by the Port Micropro - cessor ( PM) mounted on the FCH (P A-FCHA) card.
CHAPTER 7 ND-70185 (E) Page 152 Revision 3. 0 TROUBLESHOOTING 3-E PM Lockup Fa ilu r e (T e mpo ra ry) 4.1 Rep air Procedur e STEP 1: Ma ke su re that stati on-to - statio n conn e ct ions ca n be esta bl ishe d in th e PI M cont aini ng th e i ndicated FCH (PA-FCHA) car d.
ND-70185 (E) CHAPTER 7 Page 153 Revision 3. 0 TROUBLESHOOTING 13-H /I/ J Sig nalin g Li nk Fail ure (P er mane nt)/( Temporary)/(Recovery) 6. 13-H/ I/ J Signaling Link Failure ( P er manent)/( Temporar y)/(Recovery ) This mess age is dis playe d w hen t he Fu sio n link (D-c h) h as a fa ilu re.
CHAPTER 7 ND-70185 (E) Page 154 Revision 3. 0 TROUBLESHOOTING 13-H/I/J Si gnal in g Link Fai lu re ( Per m ane nt) /(T empo ra ry)/ (R ecov er y) 6.1 Rep air Procedur e • 13- H (Pe rm ane nt ) STEP 1: Make sure that the front cable is sec ure ly inserted.
ND-70185 (E) CHAPTER 7 Page 155 Revision 3. 0 TROUBLESHOOTING 23-S FCH Failure Noti fic ati on (Detec ti on) 6.2 Rep air Procedur e • 13-I (T emporary ) STEP 1: Make sure that the front cabl e is secure ly inserted. (See Fi gure 7-10 .) STEP 2: If this message has been di spla yed once or t wice, monito r the fail ure f or a wh ile.
CHAPTER 7 ND-70185 (E) Page 156 Revision 3. 0 TROUBLESHOOTING 23-S FCH Failu re Noti fi ca tion ( Dete cti on ) 7.1 Rep air Procedur e STEP 1: Make sure that the relate d Ethernet cables are secur ely inse rted int o the conn ectors. ( See th e example show n belo w.
ND-70185 (E) CHAPTER 7 Page 157 Revision 3. 0 TROUBLESHOOTING 23-S FCH Failure Noti fic ati on (Detec ti on) Figu re 7-13 How to Check 10 BASE-T Cables WARNING: When a HUB card is placed in make-busy, all BASE-T in terfaces connected to the HUB card become inoperative.
CHAPTER 7 ND-70185 (E) Page 158 Revision 3. 0 TROUBLESHOOTING 23-S FCH Failu re Noti fi ca tion ( Dete cti on ) Figure 7-14 How to Replace HUB (PA-M96) Card W A RNING: When a H U B ca r d i s pl a ced in make-bu s y, a l l BASE-T i n te r f aces conn e cted t o t he HUB card become inoperative.
ND-70185 (E) CHAPTER 7 Page 159 Revision 3. 0 TROUBLESHOOTING 23-T FCH Fault Notification (Recovery) 8. 23-T F CH Faul t No tificat ion (Recovery) This mess age is d ispl ayed whe n th e FC H (P A-FC HA ) card tha t wa s de tecte d a s faul ty is re cove red.
CHAPTER 7 ND-70185 (E) Page 160 Revision 3. 0 TROUBLESHOOTING 23-U FCH Status Informat ion 9. 23-U FCH Status Inf ormation This messa ge is displayed when the s t atus change of FCH (PA-FCHA) card i s detected, which incl udes “FCH Initia l Se ttin g Fa ilur e,” “ ETH ER T ransf er F ailur e.
ND-70185 (E) CHAPTER 7 Page 161 Revision 3. 0 TROUBLESHOOTING 23-U FCH S tatus Informa tion 9.1 FL TINF = 00H Initial S etting Failure This message i s displayed when the Ethernet Controll er Initial Setting ends in failure. The d etailed info rmation is indica ted in the fo ll owing format.
CHAPTER 7 ND-70185 (E) Page 162 Revision 3. 0 TROUBLESHOOTING 23-U FCH Status Informat ion 9.2 FL TINF = 18H Spanning T r ee Abnormal Ans wer This message is displayed when Span ning Tree Abnormal Answer is detected. The deta iled infor mation is indi - cated in the foll o wing form at.
ND-70185 (E) CHAPTER 7 Page 163 Revision 3. 0 TROUBLESHOOTING 23-U FCH S tatus Informa tion 9.2.1 Repai r Procedure A Fusion Po int Code (F PC) is ass igned usi ng the AFPC command . If any FPC data has not be en assigne d properl y , this mess age is disp layed.
CHAPTER 7 ND-70185 (E) Page 164 Revision 3. 0 TROUBLESHOOTING 23-U FCH Status Informat ion 9.3 FL TINF = 1DH ETHER T ransfer Failure This messag e is displayed when an FCH ca rd discards an abnor mal Ethe rnet packet (i.e. a bnormal IP addr ess destina t ion) t hat was received from other node on the network.
ND-70185 (E) CHAPTER 7 Page 165 Revision 3. 0 TROUBLESHOOTING 23-U FCH S tatus Informa tion 9.4 FL TINF = 1EH Spanning T ree Generation End This mes sage is di splayed when Sp anning Tree Generat ion is com plete. The d etailed i nformati on is indicated in the fo llo w in g form at .
CHAPTER 7 ND-70185 (E) Page 166 Revision 3. 0 TROUBLESHOOTING 23-U FCH Status Informat ion 9.5 FL TINF = 1FH Spanning T ree Generation Start This messa ge is dis pla yed when Spanning Tree Genera ti on sta rt s. Figu re 7- 22 23- U F CCH Status Not ificat ion - Span ning T ree Generation 9.
ND-70185 (E) CHAPTER 7 Page 167 Revision 3. 0 TROUBLESHOOTING 23-W FCH Alte r nate Rout ing Star t Notifi ca tio n 10. 23-W FCH Alternate Routing S t a rt Notific ation This messag e is displayed when the indicated FCH car d of self-Node beco mes inoperativ e.
CHAPTER 7 ND-70185 (E) Page 168 Revision 3. 0 This page is for your notes..
ND-70185 (E) CHAPTER 8 Page 169 Revision 3. 0 CHAPTER 8 EX- FCC S 1. General This fea ture provi des the fol lowing func tions (t hey are act ivated when c onnecting multiple Fusion network s) or a NEAX2000 IVS 2 system to a Fusion Netw ork using the Enhanced CCIS fe ature.
CHAPTER 8 ND-70185 (E) Page 170 Revision 3. 0 EX- FCCS EX-FCCS N etwork Config uration 2. EX-FCCS Network Con figuration 2.1 Net work Configur ation The summar y of netw ork conf igurati on cl assif ied int o tw o types a re sho wn in Ta b l e 8 - 1 .
ND-70185 (E) CHAPTER 8 Page 171 Revision 3. 0 EX- FCCS EX-FCCS Network Configu ration 2.2 Condition s for Netw ork Establi shment (NEA X2000 IVS 2 to NEAX2400 IMX Connection) Cond i tion s for co nn ec tin g the N E AX2 00 0 IV S 2 to NEAX2400 IMX are described b elo w .
CHAPTER 8 ND-70185 (E) Page 172 Revision 3. 0 EX- FCCS EX-FCCS N etwork Config uration 2.3 Condition s fo r Net wor k Establishme nt (NEAX2400 IMX to N EA X2400 IMX Connection) Conditio ns for estab lishing a FCCS network (NEAX2 400 IMX to NEAX2400 I M X) are sho wn belo w .
ND-70185 (E) CHAPTER 8 Page 173 Revision 3. 0 EX- FCCS EX-FCCS Network Configu ration 2.4 Fusion Netw ork Group ( FUG) [Fusion N etwork Group ( FUG)] Whe n conn ect ing m ul tip le Fu sio n ne twork s us ing EX -FCC S, a Fusi on Net work gro up number is re quire d to disti nguish dif ferent Fusion Netwo rk groups.
CHAPTER 8 ND-70185 (E) Page 174 Revision 3. 0 EX- FCCS EX-FCCS N etwork Config uration 2.5 Interactions 1. Condit ions for PS Serv ice Roaming and Han d-ov er feature cannot b e activ ated be tween FU G -FUG in an EX-FCCS net work and FUG-IVS 2 in a n Enhanced CCIS n etwork.
ND-70185 (E) CHAPTER 8 Page 175 Revision 3. 0 EX- FCCS EX-FCC S Fea tures 3. EX-FCCS Features 3.1 Number P orta bility [Ope rati ng Pr oce dure] 1. Log in to the NCN of the Cent er FUG from the Centralized-MA T for EX-FCCS. 2. Assign th e T eleph one Numbe r da ta u sing AELGN command.
CHAPTER 8 ND-70185 (E) Page 176 Revision 3. 0 EX- FCCS EX-FCCS F eature s 3. The nod e that req uires the data p r ogramming or data ch ange for Numbe r Portabi lity depends on th e patter n. See Figur e 8-5 and T able 8- 2 that explain th e eight patterns.
ND-70185 (E) CHAPTER 8 Page 177 Revision 3. 0 EX- FCCS EX-FCC S Fea tures 5. Up to a maximum of 120,000 T elephone Numbers may be assigned in th e entire E nhanced CCIS /EX- FCCS netw ork (includ ing T elephone Numbers in the NEAX2000 IVS 2 ) and a maximum of 48,000 per FUG (not to exceed 120,000 per to tal network) .
CHAPTER 8 ND-70185 (E) Page 178 Revision 3. 0 EX- FCCS EX-FCCS F eature s [Centra lized T raf f ic Collec ti ng] 1. T he feat ure to collec t traffic info rm ation of NEAX2000 I VS 2 system is acti va.
ND-70185 (E) CHAPTER 8 Page 179 Revision 3. 0 EX- FCCS EX-FCC S Fea tures 7. When th e faul t information occ urring at all FUGs is managed by the Centr al i zed-MA T fo r EX-FCCS, the desti nation fo.
CHAPTER 8 ND-70185 (E) Page 180 Revision 3. 0 EX- FCCS EX-FCCS F eature s 3.3 CCIS Feature s Activa ted with EX-FCCS 1. CCIS feat ures in T able 8-4 ar e a vailabl e in EX-FCCS net work. T able 8-4 CCIS Ser vice in E X-FCCS Network Note: T elephone Numbers should be used for activati ng CCIS servi ces thr ough the networ k.
ND-70185 (E) CHAPTER 8 Page 181 Revision 3. 0 EX- FCCS EX-FCC S Fea tures 2. Unique PCs (Point Codes ) in the CCIS ne twork connecte d with EX-FCCS ar e requir ed. Figure 8- 7 PC Assignment in EX-FCCS Network 3. The CCH to be used is selec ted as follo ws.
CHAPTER 8 ND-70185 (E) Page 182 Revision 3. 0 EX- FCCS EX-FCCS F eature s 3.4 Cen t raliz ed Message Center Interf ac e - EX-FCCS This sect ion explain s the conditio ns of Centra lized Mes sage Center Interf ace feat ure within EX-FCCS Net- wor k.
ND-70185 (E) CHAPTER 8 Page 183 Revision 3. 0 EX- FCCS EX-FCC S Fea tures • Call W aiting Lamp Cont roll in form ation is sent fr om th e MCI wi thi n Cent er FU G to othe r Fusio n Groups and NEAX2 000 IVS 2 system vi a CCIS.
CHAPTER 8 ND-70185 (E) Page 184 Revision 3. 0 EX- FCCS EX-FCCS F eature s 3.5 Centra liz ed Billing - EX-FCCS (P olling Method) This section explains the conditions of Centralized Billing feature within EX-FCCS N etwork.
ND-70185 (E) CHAPTER 8 Page 185 Revision 3. 0 EX- FCCS Data Programm ing 4. Data Programming This secti on expl ai ns how to assign a bran d-n ew EX-FCCS network dat a.
CHAPTER 8 ND-70185 (E) Page 186 Revision 3. 0 EX- FCCS Data Prog ramm ing 4.1 Brand-new E X-FCCS Netwo rk T o install EX-F C CS ne tw or k as a brand-ne w system between two Fusi on Groups (when no CCIS da ta ha s been ass igned), the o verall data programming p rocedure is as f ollo ws.
ND-70185 (E) CHAPTER 8 Page 187 Revision 3. 0 EX- FCCS Data Programm ing STEP 2: ARTD Assi gn the fo ll ow in g thre e ro ute s fo r this fea tu r e: • Speec h Path Route (T raf fic Route) • Signa ling Route • Dummy Route (Flag Route ) Assi gn ea ch rou te data in a ccorda nce wi th th e tab le sho wn bel ow.
CHAPTER 8 ND-70185 (E) Page 188 Revision 3. 0 EX- FCCS Data Prog ramm ing STEP 4: MBTC Assign IDLE status of trunks by des i gnating Route Number a nd Trunk Number. STEP 5: ADPC Assign th e des tinati on PC (Po int Code) on RT ( for sp eech pat h) number basis for all th e nod es in th e EX-FCCS networ k.
ND-70185 (E) CHAPTER 8 Page 189 Revision 3. 0 EX- FCCS Data Programm ing STEP 7: ACIC1 Assign CSCG for Basic/P ri mary Route . The odd numbered CSCG for Alt er nat e Route assig nment. STEP 8: ACIC2 Assign CI Cs (Circuit I dentificatio n Codes) c orrespondi ng to trun k number .
CHAPTER 8 ND-70185 (E) Page 190 Revision 3. 0 EX- FCCS Data Prog ramm ing STEP 1: ASYD Assign t he Point Code to al l the nodes i n the network uniq uely as described on Page 163. STEP 2: ADPCL Assign the destinatio n PC (Point Code) on LGRT (for speech path) number basis for all the nodes in the ne tw or k.
ND-70185 (E) CHAPTER 8 Page 191 Revision 3. 0 EX- FCCS Data Programm ing STEP 3: AFUGN Assign EX- FCCS Fusion Gro up data. Des ignate Se lf-FUG Number, Connection FUG Number a nd Fusion Poi nt Code (FPC) of the NCN within each FUG. Either o f FUG is se t as the Cente r FUG by checking the “CENTER” parameter.
CHAPTER 8 ND-70185 (E) Page 192 Revision 3. 0 EX- FCCS Data Prog ramm ing STEP 5: ARNPL Assign the access code for LCR/LCRS as assig ned in ASPAN associated with the logical routes for each external trunk assig ned in ARTD/ARTDN. STEP 6: AMND Assign t he Maximum Necess ary Digit (MND).
ND-70185 (E) CHAPTER 8 Page 193 Revision 3. 0 EX- FCCS Data Programm ing 4.2 Upgrading CCIS Netw ork to EX-FCCS Ne twor k This sect ion e xplains the wa y to assign the data when upgrading a CCIS Netw ork to an EX-FCCS Networ k.
CHAPTER 8 ND-70185 (E) Page 194 Revision 3. 0 EX- FCCS Data Prog ramm ing 1. To Log-in t o All Nodes i n EX-FCCS Network Perform t he follo w ing dat a programmin g at ea ch NCN of al l the Fusion Group s. STEP 1: AFUGN Assign EX- FCCS Fusion Group data.
ND-70185 (E) CHAPTER 8 Page 195 Revision 3. 0 EX- FCCS Data Programm ing 4.2.2 Upgrading CCIS between FUG and IVS2 System to Enhanced C CIS Net work 1. T o Log-in to All Nodes in EX-FCCS Netw ork Assi gn th e foll o wing data at th e NC N of F UG wi th Ce ntra l ized M AT fo r Fusi o n .
CHAPTER 8 ND-70185 (E) Page 196 Revision 3. 0 EX- FCCS Data Prog ramm ing 2. T o Access EX-FCCS T runk via EX-FCCS T elephone Number Assi gn the foll o wing data at N C N of the FUG . STEP 1: AEADN Assign th e ADC (Abbreviate Digit Code) for conne ction Fusion Gr oup.
ND-70185 (E) CHAPTER 8 Page 197 Revision 3. 0 EX- FCCS Data Programm ing 1. T o Log-in to All Nodes in EX-FCCS Netw ork To upgrade CCIS networ k to EX-FCCS Network as shown in the figu re on the previous page, all the IMX sys- tems ar e set as NCNs re spective ly.
CHAPTER 8 ND-70185 (E) Page 198 Revision 3. 0 This page is for your notes..
デバイスNEC NEAX2400の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
NEC NEAX2400をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNEC NEAX2400の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。NEC NEAX2400の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。NEC NEAX2400で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
NEC NEAX2400を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNEC NEAX2400の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、NEC NEAX2400に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNEC NEAX2400デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。