® PRIMESWITCH ™ 100/500 PA P USER GUIDE.
10003137.00 Rev .1 ii Document Number 10003137.00 Rev .1 Issued March 1 998 NETWORK EQUIPMENT TECHNOLOGIES, INC., (N. E.T .) PROVIDES THIS DOCUMENT AS IS, WITHOUT W A RRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO , THE IMPLIED W A RR ANTIES OF ME RCHANT ABILITY AND F ITNESS FOR A P ART ICULAR PUR POSE.
iii T rademarks The N.E.T . logo is a register ed trademark, and Prim eSwitch, Network Equipment T echno logies and N.E.T . are trademarks of Netw ork Equipment T e chnologies, In c. All other trademarks are the sole property of their respective companies.
10003137.00 Rev .1 iv.
Contents v Contents Introduction About this user guide, 1-2 Audience, 1-2 Using this guide, 1-3 Overview, 1-4 Filtering, 1-4 Buffering, 1-4 Display, 1-5 Basic Rate access, 1-5 Installation Installing .
10003137.00 Rev .1 vi Contents Commands Entering commands, 4-2 Keys, 4-3 Commands, 4-4.
Introduction 1 -1 1 Introduction.
10003137.00 Rev .1 1-2 A bout this user g uide About this user guide This user guide descr ibes the Protocol Analy zer Package (P AP). It covers the install ation and operation o f the PrimeSwitch 10 0 Series Integra ted Services Digital Netwo rk (ISDN) PA P .
Introduction 1 -3 Using this guide The guide con tains the follo wing sectio ns: Overview describe s how P AP processes network traf fic. The P AP screen describes the main screen and illustrates how P AP displays messages. Commands describes how to control P AP with function keys and typed comma nds.
10003137.00 Rev .1 1-4 Over view Overview The PrimeSwitch ISDN Protocol Analyzer Package (P AP) monitors and displays l ayer 1, layer 2 and layer 3 protocol activity o n a PrimeSw itch ISDN interface. P AP uses COM ports on the PC to transfer information to and fr om a PrimeSwi tch ISDN module.
Introduction 1 -5 This default can be overridden from the command line as foll ows: These overrides should not be used unl ess problems ar e expe rienced with the default. The size of the buffer therefore depends on the amount of memory (RAM) a vailable in the computer , and the amou nt used by other programs.
10003137.00 Rev .1 1-6 Over view Figure 1 shows the relat ionship betwee n CES, SAPI a nd TEI. Figur e 1: CES, SAPI and TEI.
Installation 2-1 2 Installation.
10003137.00 Rev .1 2-2 Inst alling P AP Installing P AP P AP can be used to mon itor traffic on either a local or a remote PrimeSwit ch. Local T o monit or lo cal traffic connect the PC to the Prime Sw itch P AP co n nector , as in th e following di agram: Figur e 2: Local connection Remote via ADLM T o monit or remote traffic, a V .
Installation 2-3 Remote via modem Y ou can also us e a modem to monito r traffic on r em ote PrimeSwitches , as shown in Fi gure 4 . Figur e 4: Local connection via modem PC Pr i m eSw i t c h Ana l o.
10003137.00 Rev .1 2-4 Connect ing P AP to an ISDN interfac e mo du l e Connecting P AP to an ISDN interface module BRMN, BRMT and early IPM N and IPMT Y ou must place the PrimeSwitch P AP Module panel in th e slot immediately to the right of the ISDN interface module that you want to monitor , wi th the connecto r located at the top.
Installation 2-5 Connecting P AP to a PC Connect the P ri m eSw itch P AP protection device to a parallel port of th e PC. T o monit or lo cal traffic: 1 Connect COM1 or COM2 on the PC to th e 25 -way D type connector on the PrimeSwitch P AP p anel using a straight through cabl e constructed a ccording to Figure 5 .
10003137.00 Rev .1 2-6 Connect ing P AP to a PC 2 Configure the ADLM V .24 as follows: Remote Remote and local Auto answer ON A T call control ON Bit rate 19 200 Parity No Stop bits 1 Number of bits 8.
Installation 2-7 Software installation The P AP softw are is install ed as part of the PrimeSwitc h Manager—NCS (Net Cen ter Software) installa tion process. T o insta ll in dividual versi ons: 1 Create a directory for the P AP software. T ype: MD P AP <Enter> 2 Change to this dir ectory .
10003137.00 Rev .1 2-8 S tarti ng P AP Starting P AP T o star t the pr ogram: 1 Either: • from Pr ogram Manager , double-click on the icon; or • from MS-DOS, change to the P A P directory and type.
The P AP screen 3 -1 3 The P AP screen.
10003137.00 Rev .1 3-2 Screen display Screen display Figur e 7: Screen display for Primary Rate Access The P AP screen, an ex ample o f which is show n in Figur e 7 , contains the foll owi ng elements.
The P AP screen 3 -3 The Basic Rate screen differs fr om the Primary Rate sc reen in the following wa ys: • the Call Reference Indicator has two digits, no t fo ur; • the current CES indicator is .
10003137.00 Rev .1 3-4 Display colors Display colors On a color moni to r , traffic is displayed i n th e fol lowing colo rs : Green Network side, layers 2 and 3.
The P AP screen 3 -5 Status line The following diagram is a sample status line with each field numb ered. Fields are descri bed in detail below . 1 Operation state STOP stopped MON monitori ng PLA Y p.
10003137.00 Rev .1 3-6 S tatus l ine 6 Call reference OXXXX call reference originating (Basic Rat e OXX) DXXXX call reference destination (Basic Rate DXX) 7 Layer 3 decode SHOR T display message type .
The P AP screen 3 -7 Layer 1 status line Layer 1 status indicators ar e dec oded from the value at the end o f the displayed line, which is the sum of the individual hexadecimal values shown in the tables belo w .
10003137.00 Rev .1 3-8 Layer 1 status li n e Network side User side V alue Indicator 00 deactivated 01 pending deactivation 02 pending activation 03 activa ted V alue Indicator 00 deactivated 01 synch.
The P AP screen 3 -9 Examples P AP disp lays layer 1, layer 2 a nd layer 3 traffic as shown in the exa mp les below . Layer 1 status change 001 number of traffic item in the buffer USER source of item.
10003137.00 Rev .1 3-10 Examp les Layer 3 m essage 031 number of traffic item in the buffer USER source of item Jan 03 date and time o f item Q931 ITU-T layer 3 protocol recommenda tio n INFOrmation m.
Commands 4-1 4 Commands.
10003137.00 Rev .1 4-2 Entering comm a nds Entering commands T o enter a comma nd: • press a Function k ey , or • type the command name and press Enter or the spa ce ba r . Some commands pr ompt for a yes/n o r esponse. T ype y or Y and pr ess Enter for yes, n or any other key for no.
Commands 4-3 Keys Key functi ons are shown below . Key Context Function Functio n key s all execute s co mmand Up arrow ↑ monitorin g pauses disp lay paused display or list scrolls up one line Down .
10003137.00 Rev .1 4-4 Com m and s Commands This section describes t he availabl e commands. Y ou sho uld note th at not a ll commands are available in every analyser state . Y ou can di splay a complete list of the co mmands available in the current state using the MORE key .
Commands 4-5 Help Displays info rmation relevant to the currently select ed command or operatio n. T o get more help, press C t o display a list of co mman ds or T to display a list of topics. Move the pointer with the cursor keys and press Ente r to sele ct.
10003137.00 Rev .1 4-6 Com m and s MakeF Creates a filter . Y ou must supply a na me and then answer a series of yes/n o que stions to define th e filter . Y o u can choose wh ether to select All , Only the liste d ones or all Except the listed o nes.
Commands 4-7 Pause Suspends the display of information during monitoring. Pressing the up arrow ( ↑ ) or Page Up key also pauses the display . While the display is paused , information received by P AP is buffered and captured to disk. Press Cont to continue display .
10003137.00 Rev .1 4-8 Com m and s ShowF If filtering is ena bled, the current filter settings are shown. Speed Selects which data rate to use. The value ca n be 2400 , 4800 , 9600 or 19 200 . T his value is saved for use the next time the softw are is opened.
デバイスNetwork Equipment Technologies 500の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Network Equipment Technologies 500をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNetwork Equipment Technologies 500の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Network Equipment Technologies 500の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Network Equipment Technologies 500で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Network Equipment Technologies 500を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNetwork Equipment Technologies 500の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Network Equipment Technologies 500に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNetwork Equipment Technologies 500デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。