KEEMUX-P2 (2-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE MAN049 Rev Date 4/8/2004 KEEMUX ® Series.
WARRANTY INFORMATION The warranty period on this product (parts and labor) is t wo (2 ) years from the date of purc hase. Please contact Network Technologies Inc at (800) 7 42-8324 (800-RGB-TECH) in the US an d Canada or (330) 562-7070 ( worldwide) or at our website at http://www.
1 TABLE OF CONTENTS INTRO DUCTION ............................................................................................................................................................................... 1 MATERIALS .............................
2 FEATURES AND FUNCTIONS 1. CPU Status LEDs- for visual indication of connection b etween the user and a specific CPU. Also used for visual indication of switch mode status 2. CPU Select Switches- push to manually switch to a specific CPU 3. Remote- (optional) for connecti on of RMT-2-ST remote cont rol 4.
3 INSTALLATION 1. Turn OFF power to all CPUs that will be connected to t he NTI S witch before connecting or disconnecting any cables. WARNING! Damage to the CPU may result if power is not turned OF F before connecting or disconnecting cab les. 2. Connect PS/2 keyboard to “USER KEYBD” port on the rear panel of the switch.
4 Units with audio support (optional) Connect the 3.5mm plug from speakers to the 3.5mm jack labe led "AUD OUT". Attach SA-xx-MM audio cables (purchased separately) betwee n the audio port on each CP U and the 3. 5mm audio jacks marked "AUD 1" on the KEEMUX s witch.
5 Keyboard Control In order to control the switch with the keyboard, COMMAND Mode must be enabl ed. To enter/exit COMMAND Mode from the keyboard: Press COMMAND Mode When the COMMAND Mode is ON, all 3 .
6 Keyboard Features The keyboard configuration o f each CPU is saved in the NTI Swit ch. For example, if the CPU attached to Port 2 had CAPS LOCK and NUM LOCK selected the last time that CPU was accessed, t hen they will automaticall y be set when that CPU is accessed again.
7 ON OFF 1 2 3 4 5 6 7 8 Dipswitches The dipswitches located next to the RS232 c onnection (Fig. 8) are used to configure the baud rate and address of the KEEMUX. The default baud rate is 9600. The default address is 1. Use the charts below to change the baud rate and address a s needed.
8 RS232 Interface Test Program RS232 communication is configur ed using the RMTEST program, locate d on the supplied floppy disk. This soft ware allows a user to test the functions of an NTI KEEMUX or Multi-user/Multi-platform switch RS232 interface. The RMTEST program generates a main menu with the 3 selections described below: MAIN OPTIONS 1.
9 RS232 Port (DB-9 MALE) PIN SIGNA L FUNCTION 1 - No connection 2 RXD Receive dat a 3 TXD Transmit data 4 DTR Data terminal ready 5 GND Signal ground 6 DSR Data set ready 7 RTS Request to send 8 CTS C.
10 SERIAL NO.: DATE: INSPECTED BY: KEEMUX-P2 KEEMUX-P2-RMT KEEMUX-P2-AUD KEEMUX-P2-DV Man049 Rev. 4/8/04.
デバイスNetwork Technologies KEEMUX-P2の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Network Technologies KEEMUX-P2をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNetwork Technologies KEEMUX-P2の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Network Technologies KEEMUX-P2の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Network Technologies KEEMUX-P2で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Network Technologies KEEMUX-P2を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNetwork Technologies KEEMUX-P2の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Network Technologies KEEMUX-P2に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNetwork Technologies KEEMUX-P2デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。