New Buck Corporation P.O. Box 69 8000 Hwy. 226 South Spruce Pine, NC 28777 BUCK ST OVE MODEL ZCBB VENTLESS FIREBOX ENCLOSURE FOR GAS-FIRED DECORA TIVE TYPE UNVENTED ROOM HEA TERS FOR USE WITH OPTIONAL WOODEN FLUSH MOUNT MANTEL (FF) AND OPTIONAL WOODEN SURROUND (WS) INSTALLER: Leave this manual with the appliance.
.
T ABLE OF CONTENTS Safety Information and Warnings ....................................................................................... 3 Installation .................................................................................................
2.
SAFETY INFORMA TION W ARNINGS IMPORTANT: READ THIS OWNER’S MANUAL CAREF ULLY AND COMPLETELY BEFORE TRYING TO ASSEMBLE, INSTA LL, OPERATE, OR SERVICE THIS APPLIANCE (FIREBOX ENCLOSURE). Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea.
W ARNING DO NOT USE A BLOWER IN SERT, HEAT EXCHANGER INSERT, OR OTHER ACCESSO RY NOT APPROVED FOR USE WITH THIS HEATER. THIS HEATER SHALL NO T BE INSTALLED IN A CONFINED SPACE UNLESS PR OVISIONS ARE MADE FOR ADEQUATE COMBUSTION AND VENTILATION AIR. ”See Page 10, for “Producing Adequate Ventilation”.
INST ALLA TION Your New Buck Ventless Firebox Enclosure may be installed in Residentia l or *After-Market Manufactured Mobile Homes. This appliance may be installed in an *After Market Manufactured Mobile Home, where not prohibited by state or local codes.
FIREBOX AND FRAMING DIMENSIONS (ZC) & (FF) NOTE: SEE PAGE 10 IF AN OPTIONAL WOODEN FLUSH M OUNT MANTEL FRONT (FF) IS TO BE USED. Figure 2 GAS LINE 33-1/8" 18-15/16" 35-5/8" 36-5/8&q.
Figure 3 FIREBOX CLEARANCES The firebox may be placed dire ctly on a combustible floor, against a combustible wall at m arked clearances, or on a raised wooden platform. If the firebox is to b e installed on a raised wood en platform, the platform m ust be a continuous level surface.
FINISHING YOUR FIREBOX There is a wide variety of finishing material available for your firebox from formal wall treatments with m arble and mantels, to rustic wood paneling, stone or brick. IT IS IMPORTANT THAT THE BLACK FACE OF THE FIREBOX NOT BE COVERED WITH ANY TYPE OF COMBUSTIBLE MATE RIAL.
MANTEL PROFILES FOR VE NTLESS FIREBOX ENCLOSURE (UNIVERSAL BOX) ZERO CL EARANCE CABINET MUST BE FOLLOWED A 3” 3/4” 3 1/2” 4” B CANOPY STANDOFF COMBUSTIBLE MATERIALS ZCBB MANTEL CLEARANCES MANTEL WIDTH MANTEL HEIGHT (“ A ” inches ) (“ B ” inches above firebox opening) 6.
D DATE REV. BY INSTALLATION INSTRUC TIONS FOR MODEL ZCBB OPTIONAL WOODEN FLUSH MOUNT MANTEL FRONT (FF) (KIT#PAKDMZCBBFF) “NOTE: Follow the framing instructions on page (s) 6 & 7. With the excep tion of the placement of the ZCBB in the framed open ing .
INSTALLATION I NSTRUCTI ONS FOR MODEL ZCBB OPTIONAL WOODEN SURROUND (WS) (KIT# PAKDMZCBB) CLEARANCES: 1. Sidewall Clearances: Clearances from the side of the firebox opening to any adjacent combustible wall should not be less than 7". See Figure 4 2.
REAR VIEW After assembling the WS you must insert the ZCBB. It is best to insert the ZCBB from the rear of the WS, this gives you more area to hold the ZCBB and re duces the risk of scratc hing the surface of the front area of the base (hea rth) area.
This section is used for residential inst allation or mobile home installation. UNCONFINED SPACE: An unconfined space has a minimum air volume of 50 cubic feet for each 1,000 BTU/Hr (4.8m 3 per Kw) input rating of all appliances in the space (Cubic feet equals L ength x Width x Height of space).
3. Add the BTU/Hr of all fuel burning appliances in the space. Vent-Free Heater _________________________BTU/Hr. Gas Water Heater* _________________________BTU/Hr. Gas Furnace _________________________BTU/Hr. Vented Gas Heater _________________________BTU/Hr.
VENTILA TION AIR VENTILATION AIR FROM INSIDE BUILDING This fresh air would come from an adjoining unconf ined sp ace. When venting to an adjo ining space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see Options 1 and 2, Figure 6).
Figure 7 Ventilation Air From Outdoors W ARNING THIS HEATER MUST HAVE FRESH AIR FOR PROPER OPERATION. IF NOT, POOR FUEL COMBUSTION COULD RESULT. READ THE FOLLOWING INSTRUCTIONS TO ENSURE PROPER FRESH AIR FOR THIS AND OTHER FUEL-BURNING APPLIANCES IN YOUR HOME.
OPTIONAL BLOWER INST ALLA TION The Model ZCBB has an optional MA ZCBB714 blow er kit that can be purchased from your dealer. You will need to follow these steps and the di agram below and the wiring diagram on page 18.
W ARNING: CHILDREN AND ADULTS SHOU LD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA TURES AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITI ON. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN IN THE SAME ROOM AS GAS LOGS. W ARNING: CLOTHING OR OTHER FLA MMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THESE GAS LOGS.
REPLACEMENT PARTS 1. PULL SCREEN (2) PER UNIT 2. SCREEN RODS (2) PER UNIT 3. REAR REFRACTORY AND SIDE REFRACTORY 2 PIECES PER UNIT 6. CANOPY 7. DOOR KIT (PART # MAZCBBDOORS) PARTS MAY BE OBTAINED THROUGH YOUR LO CAL NBC DEALER. IN ABSENCE OF A DEALER, PLEASE CONTACT NEW BUCK CORPORATION AT P.
NEW BUCK CORPORA TION We reserve the right to amend th ese specifications at any tim e without notice. The only warranty applicable is our standard wr itten warranty.
デバイスNew Buck Corporation ZCBBの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
New Buck Corporation ZCBBをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNew Buck Corporation ZCBBの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。New Buck Corporation ZCBBの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。New Buck Corporation ZCBBで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
New Buck Corporation ZCBBを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNew Buck Corporation ZCBBの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、New Buck Corporation ZCBBに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNew Buck Corporation ZCBBデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。