Niles AudioメーカーMSU140の使用説明書/サービス説明書
ページ先へ移動 of 20
T ABLE OF CONTENTS Introduction 1 Features and Benefits 2 MSU140 Parts Guide 4 Installation Considerations 5 Installation 8 T esting the IR Extender System 11 Power Status 13 T rouble- Shooting 15 Spe.
I NFRARED M AIN S YS TEM U NIT 2 Features and Benefits The MSU140 offers a number of improvements over other IR Extender Main System Units: • Universal system—compatible with virtually all brands of A/V equipment and remote controls. • Accommodates one IR sensor or keypad.
I NFRARED M AIN S YS TEM U NIT 3 1234 POWER +12V DC 3-30V AC/DC STATUS IN FLASHER OUTPUTS MSU140 IR MAIN SYSTEM UNIT INPUT 1 Niles IR Flasher MSU140 WS100 IR Sensor Power , IR data, status signal and .
1234 POWER +12V DC 3-30V AC/DC ST ATUS IN FLASHER OUTPUTS MSU140 IR MAIN SYSTEM UNIT INPUT 1 4 I NFRARED M AIN S YS TEM U NIT MSU140 Parts Guide 1. 12V DC Jack – Provides 12 volt DC power to MSU via a regulated power supply . 2. IR Flasher Outputs – 3.
Installation Considerations Placement of the MSU140 Place the MSU140 conveniently close to the equipment it will be controlling. Generally , the unit is placed in a con- cealed location because its controls and indicators are only used during installation.
Wiring From every IR Sensor location you must “home-run” a category 5 cable back to the MSU140. Home run means that an individual cable is connected between each IR Sensor and the MSU140. See Figure 4. 6 I NFRARED M AIN S YS TEM U NIT “TECH TIP” Wire size is expressed by it’ s AWG (American Wire Gauge) number .
Intellipad Wiring When you are placing both a Intellipad and a sensor (or two keypads) in one room you may “daisy-chain” using a single cable. A cable is run between the keypad and the sensor and a single cable is run from the sensor back to the MSU140.
1234 POWER +12V DC 3-30V AC/DC STATUS IN FLASHER OUTPUTS MSU140 IR MAIN SYSTEM UNIT INPUT 1 Sensor/Keypad Cable The MSU140 connects to IR sensors and the Intellipad with category 5 cable, with a maximum cable run of 500'. Flasher Cable Niles infrared flashers come supplied with a 10 foot 2-con- ductor 22 gauge cable.
9 I NFRARED M AIN S YS TEM U NIT STEP DESCRIPTION 1. C onnect and test the power supply . If it tests OK, unplug the connector from the power socket and proceed. A) Plug the supplied 12vDC power supply into an unswitched 120V AC outlet, 50-60 HZ . B) Plug the connector into the socket marked “Power” on the MSU140.
STEP DESCRIPTION 10 I NFRARED M AIN S YS TEM U NIT 1234 FLASHER OUTPUTS BE SURE TO OBSERVE PROPER POLARITY WHEN EXTENDING THE FLASHER WIRE. The wire lead marked with a gray stripe is positive ( + ) ; the unmarked lead is nega- tive (- ) . 3. T est for shorts and interference.
11 I NFRARED M AIN S YS TEM U NIT T esting the IR Extender System T est your IR Extender system by following these three principal guidelines: 1. All components can be operated. T est all of your remote controls for all of your equipment. 2. Operation is consistent.
12 I NFRARED M AIN S YS TEM U NIT Power Status — Introduction T o properly wire an Intellipad to the MSU140, refer to Figure 5. By providing 3-30V AC/DC to the status input jack of your MSU140 you can send a status signal to sensors or an IntelliPad without running any additional wiring.
13 I NFRARED M AIN S YS TEM U NIT Power Status — Installation Considerations Proper Power Supply If status is being supplied from a switched outlet you must connect a Niles 12vDC wall adapter (Niles FG01035) into the switched AC power outlet of the preamp/receiver in your system.
14 I NFRARED M AIN S YS TEM U NIT OUTPUT TO MSU POWER STATUS +12V DC IRH610 IR EXPANSION HUB INPUT 1 INPUT 4 INPUT 5 INPUT 6 INPUT 2 INPUT 3 1234 POWER +12V DC 3-30V AC/DC STATUS IN FLASHER OUTPUTS MS.
15 I NFRARED M AIN S YS TEM U NIT T roubleshooting Guidelines There are three basic problems which prevent proper oper- ation. In the order of probability the problems are: 1.– Bad Connections or Wiring If the connections or wiring are wrong, loose, shorted or open the system will not operate properly .
16 I NFRARED M AIN S YS TEM U NIT Solution: T o eliminate EMI tr y the following methods: 1. Move the sensor or the sensor cable away from the EMI source or move the sour ce of the EMI away from the sensor or the cable.
17 Specifications IR System Compatible with virtually all brands of remotes using carrier frequencies between 26 and 1 05kHz. W iring Requirements Individual home-runs of category 5 cable from each sensor/keypad. Unit Dimensions 4-3/4” wide x 1-1/4” high x 2” deep Power Requirements 12VDC power supply (included).
18 I NFRARED M AIN S YS TEM U NIT Addendum: Using the MSU140 with the IntelliControl ® automation system 1234 POWER +12V DC 3-30V AC/DC STATUS IN FLASHER OUTPUTS MSU140 IR MAIN SYSTEM UNIT INPUT 1 15.
Nil es Au dio Corporation www .nilesaudio.com 1 233 1 S.W . 1 30 Street Miami, Florida, 33 1 86 T el: (305) 238-4373 Fax: (305) 238-0 1 85 © 2005 Niles Audio Corporation. All rights reserved. Niles, the Niles logo, IntelliPad and Blending High Fidelity and Architecture are registered trademarks of Niles Audio Corporation.
MSU140 INFRARED MAIN SYSTEM UNIT MSU140 B LENDING H IGH F IDELITY AND A RCHITECTURE ® INSTALLATION & OPER ATION GUIDE DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 20.
デバイスNiles Audio MSU140の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Niles Audio MSU140をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNiles Audio MSU140の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Niles Audio MSU140の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Niles Audio MSU140で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Niles Audio MSU140を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNiles Audio MSU140の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Niles Audio MSU140に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNiles Audio MSU140デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。