INFRARED MAIN SYSTEM UNIT MSU 250 INST ALLA TION GUIDE B LENDING H IGH F IDELITY A N D A RCHITECTURE ®.
CONGRA TULA TIONS! Thank you for choosing MSU-250 infrared (IR) extender system from Niles. With proper installa- tion and operation, you should enjoy years of trouble-free use. Niles manufactures the industry’ s most complete line of custom installation components and accessories for audio/video systems.
NILES AUDIO CORPORA TION – 1-800-BUY -HIFI – 305-238-4373 1 INTRODUCTION The MSU-250 an infrared (IR) extender system enables you to control your IR remote controlled A/V equipment from a remote location.
2 FEA TURES AND BENEFITS The MSU250 offers a number of improvements over other IR Extender Main System Units: • Universal system—compatible with virtually all brands of A/V equipment and remote controls • Accommodates two IR sensors or keypads • Provides five flasher outputs via convenient 3.
12VDC power supply (supplied with the MSU250 Main System Unit) plugged into an unswitched AC outlet powers the system Power , IR da ta, status signal and ground via CA T -5 wire 12VDC power supply (No.
1. 12VDC Jack – Provides 12 volt DC power to MSU via a regulated power supply 2. IR Flasher Outputs – 3.5mm jacks provide output for either single or dual (MF1, MF1VF , MF2, MF2VF) low-level flashers 3.
5. Status/IR Confir mation LED – This LED performs two functions: (1) it provides a visible indication of system status via a green LED and (2) confirms the reception of IR data via a blinking blue LED 6.
INST ALLA TION CONSIDERA TIONS (CONTINUED) WIRING From every IR Sensor location you must “home-run” a CA T -5 cable back to the MSU250. Home run means that an individual cable is connected between each IR Sensor and the MSU250 (Figure 4).
Figure 5 An IR sensor cable is “daisy-chained” from an IntelliPad, to a sensor and back to the MSU250 INST ALLA TION CONSIDERA TIONS (CONTINUED) INTELLIP AD WIRING When you are placing both a IntelliPad and a sensor (or two keypads) in one room you may “daisy- chain” using a single cable.
T INST ALLA TION TOOLS REQUIRED • 1/8” (0.3cm) Standard Slotted Screwdriver • Wire Stripper INST ALLA TION Before you begin, make sure that the sensor/keypad cables, the flasher cables and the 12VDC power supply cable will all reach the proposed location of the MSU250.
T INST ALLA TION (CONTINUED) 1. Connect and test the power supply . If it tests OK, unplug the connector from the power socket and proceed A) Plug the supplied 12VDC power supply into an unswitched 12.
INST ALLA TION (CONTINUED) 3. T est for shorts and interference . A) Reconnect the power supply . If the power LED lights and the IR test LED stays off, unplug the connector from the power socket and proceed to Step 4.
OPERA TION TESTING THE IR EXTENDER SYSTEM TESTING THE IR EXTENDER SYSTEM T est your IR extender system by following the three principal guidelines: 1. All components can be operated. T est all of your remote controls for all of your equipment 2. Operation is consistent.
OPERA TION Example include: • Dropping a motorized screen • Activating a television lift • T urning on a voltage controlled switching device (e .g.: Niles AC-3 voltage controlled switched outlet) INST ALLA TION Simply plug a cable with a 3.5mm plug (tip=positive, sleeve=ground) into the jack labeled “12VDC/200mA OUTPUT”.
OPERA TION (CONTINUED) connected to one of your sensor wires will display the power status of your system. POWER ST A TUS — INST ALLA TION CONSIDERA TIONS PROPER POWER SUPPL Y If status is being sup.
OPERA TION (CONTINUED) 14 12VDC Power supply (Not Supplied) plugged into a switched outlet Niles stock# FG00060A Infrared Sensors MSU250 Main System Unit IRH610 Expansion Hub Figure 9 Wiring diagram for expanding a system using the IRH610 Infrared Expansion Hub.
TROUBLESHOOTING TROUBLESHOOTING GUIDELINES There are three basic problems which prevent proper operation. In the order of probability the problems are: 1. Bad Connections or Wiring If the connections or wiring are wrong, loose, shorted or open the system will not operate properly .
TROUBLESHOOTING (CONTINUED) 1. Move the sensor or the sensor cable away from the EMI source or move the source of the EMI away from the sensor or the cable 2. Connect the sensor ’ s GND terminal to true earth ground (if this isn’t feasible use the main system unit’ s GND terminal) 3.
NILES AUDIO CORPORA TION – 1-800-BUY -HIFI – 305-238-4373 17 SPECIFICA TIONS IR System Compatible with virtually all brands of remotes using carrier frequencies between 26 and 105kHz. Wiring Requirements Individual home-runs of CA T -5 cable from each sensor/keypad.
Using the MSU250 with the IntelliControl Home Theater automation system When connecting an MSU flasher output to an IntelliControl “Home Theater” port, a 150-Ohm resis- tor must be placed between the data and the ground line of the IntelliControl IR sensor input (see figure above).
NILES AUDIO CORPORA TION – 1-800-BUY -HIFI – 305-238-4373 19 NOTES __________________________________________________________________________ ______________________________________________________.
20 LIMITED W ARRANTY NI LE S A UDI O C OR PO R ATI ON ( “N IL E S” ) WA RR A N TS I T S AC TI V E P ROD U CT S T O TH E O RIG I NA L P UR CH A SE R T O BE F RE E O F MA N UF AC TU RI NG D EF E CT S IN M ATE RI A L A ND W OR K MA N SH IP F OR A P E RI OD O F T WO Y E A RS F RO M DATE O F PU RC H AS E .
NILES AUDIO CORPORA TION – 1-800-BUY -HIFI – 305-238-4373 21 DET ACH HERE AND RETURN TO: NI LES AUDIO CORPORA TION WARRAN TY REGISTRA TION DEPT . P .
Niles Audio Corporation 12331 S.W . 130 Street Miami, Florida 33186 1-305-238-4373 1-800-BUY -HIFI – www.nilesaudio.com ©2007 Niles Audio Corporation. All rights reserved. Niles, the Niles logos and Blending High Fidelity and Architecture are registered trademarks of Niles Audio Corporation.
デバイスNiles Audio MSU250の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Niles Audio MSU250をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNiles Audio MSU250の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Niles Audio MSU250の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Niles Audio MSU250で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Niles Audio MSU250を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNiles Audio MSU250の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Niles Audio MSU250に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNiles Audio MSU250デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。