Nortel NetworksメーカーP0886634の使用説明書/サービス説明書
ページ先へ移動 of 37
•••••••••••••••••••••••••••••••••••••••••••• • •••••••••••••••••••••••• Norstar V oice Mail 4.
.
P0886634 Issue 1.0 FAX Installation Guide Contents Regulatory information iii Repair facilities iv Chapter 1 Introduction to Norstar Voice Mail FAX 1 FAX overview 1 DFC overview 3 Specifications 3 Spe.
ii FAX Installation Guide P0886634 Issue 1.0.
Regulatory information iii P0886634 Issue 1.0 FAX Installation Guide Regulator y information FCC Regulations This equipment complies with Part 68 Rules and Regulations of the FCC Regulations for direct connection to the public switched telephone network.
iv Repair facilities FAX Installation Guide P0886634 Issue 1.0 Repair facilities In the event of equipment malfunction, all repairs must be performed by Northern Telecom or by one of its authorized dealers. Note: You receive an RA# when you call the repair center in Nashville.
P0886634 Issue 1.0 FAX Installation Guide Introduction to Norstar V oice Mail F AX Norstar Voice Mail FAX provides Norstar Voice Mail with fax functionality. This installation guide is intended for the installer of Norstar Voice Mail FAX and describes how the FAX option should be installed and prepared for operation.
2 Introduction to Norstar Voice Mail FAX FAX Installation Guide P0886634 Issue 1.0 Figure 1 FAX overview External fax machine External caller receives a fax from Fax-on-Demand Mailbox. OR Fax sent to office fax machine behind Norstar or to a Personal Mailbox.
Introduction to Norstar Voice Mail FAX 3 P0886634 Issue 1.0 FAX Installation Guide DFC over view The Digital Fax Card (DFC) is installed in an expansion bus slot on the Norstar Application Module (NAM) and supports four Fax Channels. There are no Time Compression Multiplexing (TCM) connections to the DFC.
4 Introduction to Norstar Voice Mail FAX FAX Installation Guide P0886634 Issue 1.0 Precautions Before installing or upgrading a DFC, you must take the following precautions: • Shut down the Norstar Voice Mail system —A shutdown procedure allows Norstar Voice Mail to perform all necessary shutdown activities before power is removed.
P0886634 Issue 1.0 FAX Installation Guide Installing the DFC on systems equipped with DVCs Only one DFC can be installed in the Norstar Applications Module (NAM). The DFC connects to the DVCs through the PCM Expansion Bus (PEB) cable. This cable must be connected from the DFC to each DVC.
6 Installing the DFC on systems equipped with DVCs FAX Installation Guide P0886634 Issue 1.0 Installation over view To add Norstar Voice Mail FAX to a system equipped with DVCs you must: • Set the D.
Installing the DFC on systems equipped with DVCs 7 P0886634 Issue 1.0 FAX Installation Guide Opening the NAM 1. Warn customers that Norstar Voice Mail will be out of service while you are installing the FAX option. 2. Shutdown the Norstar Voice Mail system.
8 Installing the DFC on systems equipped with DVCs FAX Installation Guide P0886634 Issue 1.0 Figure 4 Removing the front cover Installing the DFC in the NAM 1. Make sure you are wearing your antistatic grounding strap. Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface.
Installing the DFC on systems equipped with DVCs 9 P0886634 Issue 1.0 FAX Installation Guide Figure 5 Locating the expansion bus slots on a NAM Figure 6 Locating the expansion bus slots on a NAM II DF.
10 Installing the DFC on systems equipped with DVCs FAX Installation Guide P0886634 Issue 1.0 3. Switch SW1 should be set according to the following table: 4. Switch SW2 should be set according to the following table: 5. Ensure there is a jumper on position 10 of the INTERRUPT.
Installing the DFC on systems equipped with DVCs 11 P0886634 Issue 1.0 FAX Installation Guide Installing the PEB Cable Figure 7 shows an example of how the PEB cable is installed on an earlier NAM. In this example, the Norstar Voice Mail module is equipped with four DVCs.
12 Installing the DFC on systems equipped with DVCs FAX Installation Guide P0886634 Issue 1.0 1. Remove all DVCs from the NAM. 2. Remove the PEB terminator XRN2 from DVC 1.
Installing the DFC on systems equipped with DVCs 13 P0886634 Issue 1.0 FAX Installation Guide Figure 11 Installing the PEB Cable 5. Insert the DVCs and connect the PEB cable to each card. Note: To ease installation, start with the DVC that is closest to the DFC and finish with the DVC farthest away.
14 Installing the DFC on systems equipped with DVCs FAX Installation Guide P0886634 Issue 1.0 6. Close the module door. Note: To lock the door, turn the lock 90° clockwise until the screwdriver slot is horizontal. 7. Plug the power cord into the AC outlet.
Installing the DFC on systems equipped with DVCs 15 P0886634 Issue 1.0 FAX Installation Guide 12. Fold the PEB cable so it lies flat against the card edges. 13. Replace the front cover and close the module door. 14. Plug the power cord into the AC outlet.
16 Installing the DFC on systems equipped with DVCs FAX Installation Guide P0886634 Issue 1.0.
P0886634 Issue 1.0 FAX Installation Guide Installing the DFC on systems equipped with a BIC Only one DFC can be installed in the NAM. The DFC connects to the Media Services Bus Expansion Card (BEC) daughterboard attached to the Media Services Base Interface Card (BIC) through the PCM Expansion Bus (PEB) cable.
18 Installing the DFC on systems equipped with a BIC FAX Installation Guide P0886634 Issue 1.0 Installation over view To add Norstar Voice Mail FAX to a system equipped with a BIC you must: • Remove.
Installing the DFC on systems equipped with a BIC 19 P0886634 Issue 1.0 FAX Installation Guide Figure 13 Disconnecting the Serial Ports A and B and the keyboard/mouse connector 6. Locate the BIC and disconnect the fiber cable.The BIC is located in Slot 2 of the NAM II and in Slot 4 of the new NAM.
20 Installing the DFC on systems equipped with a BIC FAX Installation Guide P0886634 Issue 1.0 2. Place the BIC on a flat surface, with the components facing up. Refer to Figure 15 on page 21. 3. Unpack the small plastic bag from the shipping container.
Installing the DFC on systems equipped with a BIC 21 P0886634 Issue 1.0 FAX Installation Guide Figure 15 BIC connection points 7. Lightly press the BEC daughterboard down onto the female BEC daughterboard connectors on the BIC. The BIC connection screw hole posts should be flush with the BEC daughterboard screw holes.
22 Installing the DFC on systems equipped with a BIC FAX Installation Guide P0886634 Issue 1.0 Re-installing the BIC in the NAM Before you begin to install the BIC, ensure you use an antistatic strap to ground yourself.
Installing the DFC on systems equipped with a BIC 23 P0886634 Issue 1.0 FAX Installation Guide Figure 17 Re-installing the BIC in a new NAM 5. Push the BIC straight back until it fits snugly in place. Ensure the edge connector is firmly inserted into the socket.
24 Installing the DFC on systems equipped with a BIC FAX Installation Guide P0886634 Issue 1.0 Installing the DFC in the NAM 1. Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface. 2.
Installing the DFC on systems equipped with a BIC 25 P0886634 Issue 1.0 FAX Installation Guide Note: The BIC must have a BEC daughterboard installed before it can be connected to the DFC. For instructions on installing the BEC daughterboard, refer to " Installing the Media Services Bus Expansion Card (BEC) on the BIC" on page 19.
26 Installing the DFC on systems equipped with a BIC FAX Installation Guide P0886634 Issue 1.0 Figure 19 Connecting the BIC to the DFC To connect the BIC to the DFC with the PEB cable: 1. Connect one end of the PEB cable to the PEB socket on the DFC. The PEB cable is keyed and can only be installed one way.
Installing the DFC on systems equipped with a BIC 27 P0886634 Issue 1.0 FAX Installation Guide Enabling the F AX software The FAX option must be enabled after installing the DFC. After FAX capability has been added to Norstar Voice Mail, you can add or customize Fax Overflow and Fax-on-demand information.
28 Installing the DFC on systems equipped with a BIC FAX Installation Guide P0886634 Issue 1.0.
29 FAX Installation Guide P0886634 Issue 1.0 T ell us what you think... This is your document. Nortel wants it to work well for you. Please take a fe w minutes to answer the questions on the other side of this page. Fax it back to us at the number provided, or mail it to the address belo w .
30 FAX Installation Guide P0886634 Issue 1.0 Fax to: Documentation User Comments Surve y Nortel Product T raining and Documentation 1-972-684-8699 Please circle the most appropriate number on the scale for each question. 1. Overall, are you satisfied with this document? Y e s 7654321N o 2.
1-800-4 NORTEL www .nor tel.com/norstar Norstar is a trademark of Nor thern T elecom. P0886634 Issue 1.0 Printed in Canada.
デバイスNortel Networks P0886634の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Nortel Networks P0886634をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNortel Networks P0886634の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Nortel Networks P0886634の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Nortel Networks P0886634で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Nortel Networks P0886634を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNortel Networks P0886634の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Nortel Networks P0886634に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNortel Networks P0886634デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。