Northern Industrial ToolsメーカーST80iの使用説明書/サービス説明書
ページ先へ移動 of 17
67 L 23(5$ 7,1*0$18$/.
Please read and save these instructions. Read through this owner’s manual carefully before using product. Protect yourself and others by observing all safety information, warnings, and cautions. Fa ilure to comply with instructions co uld result in personal inju ry and/or damage to product or property.
Northern Industrial Welding 2 Operating Instructions and Parts Manual ST80i Specifications and Dimension MODEL ST80i Power supply (v) 1ph-120V-60HZ No-load voltage (v) 75V Output Range (A) 20-75A 90A Peak Duty cycle (%) 20% @75A Suggested electrode E6013,E70 14, E701 8, Stainless steel Electrode Diameter (Inch) 1/16”, 5/64”, 3/32” ( 1.
Northern Industrial Welding 3 Operating Instructions and Parts Manual ST80i Welding Cable a nd Electrode Holder One end of cable is connected to output connectors of the machine. T he electrode is clamped in the electrode hold er for welding. Output “-” Connector This is the connector for grounding cable when STICK welding.
Northern Industrial Welding 4 Operating Instructions and Parts Manual ST80i General Safety Information 1.1 Your Welding Env ironment -Keep the environment you will be welding in free from flammable materials. -Always keep a fi re extinguisher accessible to your welding environment.
Northern Industrial Welding 5 Operating Instructions and Parts Manual ST80i connections are a hazard, so secure the ground lead before weldin g. -Wear dry protective apparel: coat, shirt, gloves and insulated footwear. -Insulate yourself fr om the work piece.
Northern Industrial Welding 6 Operating Instructions and Parts Manual ST80i explosive materials. -Do not operate any electric a rc welder in areas where flammable or explosive materials are present. -Remove all flammable materials within 35 feet of the welding arc.
Northern Industrial Welding 7 Operating Instructions and Parts Manual ST80i -Always have power disconne cted when working on internal components. - Do not touch or handle PC board without being properl y gr ounded with a wrist strap. Put PC board in static proof bag to move or ship.
Northern Industrial Welding 8 Operating Instructions and Parts Manual ST80i 4. Ground clamp c onnection Clear any dirt, rust, scale, oil or paint on the ground clamp. Make certain you have a good soli d ground connection. A poor connection at the ground clamp will waste po wer and heat.
Northern Industrial Welding 9 Operating Instructions and Parts Manual ST80i c. The bead will be flat and porous d. Rod may be freeze or stick to work piece Note: Rate of travel over the work also affects the weld. To ensure proper penetration and en oug h deposit of rod, the arc must be moved slowly and evenly alo ng the weld seam.
Northern Industrial Welding 10 Operating Instructions and Parts Manual ST80i A good arc is accompanied by a crisp , cracking sound. T he sound is similar to that made by eggs frying. T o lay a weld bead, only 2 movements are required; downward and in the direction the wel d is to be laid, as in following figure: 2.
Northern Industrial Welding 11 Operating Instructions and Parts Manual ST80i A. Weld speed is too fast. B. Weld speed is too slow. C. Arc is too long. D. Ideal weld. A solid weld bead requires that the electrode be moved slo wly and steadily along the weld seam.
Northern Industrial Welding 12 Operating Instructions and Parts Manual ST80i Trouble shooting Chart No. Breakdown Analysis Solutions Poor ventilation leads to over-heat protection Improve ventilation Internal temperature is too high Will automatically recover when the temperature lowers.
Northern Industrial Welding 13 Operating Instructions and Parts Manual ST80i Electrode Holder’s capacity is too small; Replace with a higher Amperage Holder Cable is of small size Replace it with an.
Northern Industrial Welding 14 Operating Instructions and Parts Manual ST80i Warranty LIMITED ONE-YEAR WARRA NTY Should this product fail to perform satisfactorily due to a defect o r po or workmanship within ONE YEAR from t he date of purchase, return it to the place of purchase and it will be repl aced, free of charge.
Northern Industrial Welding 15 Operating Instructions and Parts Manual ST80i 9 Dins connect or (copper) ( ROHS ) 2.07.57.147 2 10 Thermal protection Indicating light 1.2.07.02.3010 1 11 Power Indicating light 1.2.07.02.3011 1 12 Output fixed board 1.
Northern Industrial Welding 16 Operating Instructions and Parts Manual ST80i • ANSI Standard Z87.1 — SAFE PRACTICE FOR OCCUPATION AND EDUCATIONAL EYE AND FACE PROTECTION Obtainable from: American National Standards Institute (ANSI) 11 West 42nd St.
デバイスNorthern Industrial Tools ST80iの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Northern Industrial Tools ST80iをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNorthern Industrial Tools ST80iの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Northern Industrial Tools ST80iの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Northern Industrial Tools ST80iで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Northern Industrial Tools ST80iを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNorthern Industrial Tools ST80iの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Northern Industrial Tools ST80iに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNorthern Industrial Tools ST80iデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。