BUIL T -IN CENTRAL CLEANING SYSTEM MODEL: CV -352 GENERAL INFORMATION .............. 2 LAYOUT AND PLANNING ............... 2 Examples ........................................2 Locating the Power Unit ..................3 Locating the Wall Inlets ......
2 GENERAL INFORMA TION LA YOUT AND PLANNING EXAMPLES The Nu T one Central Cleaning System consists of a Central Power Unit, PVC Tubing, PVC Fittings, automatic switch operated Wall Inlets, a flexible hose and various cleaning attachments. As an aid in planning the installation, look at the following examples.
3 FIGURE 3 THE SPLIT -LEVEL HOUSE Like the two-story house, the split level installation commonly calls for a two-level trunk line. Here, the power unit is located in the garage. The intake tubing runs exposed up the garage wall and into the ground level section's attic.
4 INST ALLA TION IN NEW CONSTRUCTION W ALL INLET ROUGH-IN 1. Once the locations for wall inlets have been determined, mount all inlet brackets. 2. To locate bracket on wall stud, measure approximately 18" up from finished floor level. (Height may vary according to individual preference.
5 FIGURE 7 INCLUDE FITTING RECESS IN MEASUREMENT TUBING MEASUREMENT PVC TUBING FIT TING FIT TING 3 / 4 " 3 / 4 " FIGURE 8 FIGURE 9 FIGURE 10 FIGURE 11 FIGURE 12 TUBING INST ALLA TION 1. Cut a 2 1 ⁄ 2 " diameter hole in sole plate, header or stud directly in line with opening of inlet bracket fitting.
6 FIGURE 15 FIGURE 16 MODEL 365 DOUBLE FLANGED TEE W ALL INLET MOUNTING BRACKET SHORTEN W ALL FIGURE 13 FIGURE 14 W ALL INLET INST ALLA TION MODEL 360 W ALL INLET(361 Rough in) 1. Once the walls have been finished, install the wall inlets. 2. Remove the cardboard plaster guard.
DIMENSIONAL CHART MODEL DIMENSION CV-352 A 27" B7 3 ⁄ 4 " C6 1 ⁄ 2 " D1 3 5 ⁄ 8 " 7 POWER UNIT INST ALLA TION MOUNTING See Figure 18. 1. Locate the power unit within six feet of a grounded electrical outlet. 2. Drill 3 ⁄ 16 " diameter pilot holes for the two (2) mounting screws in a wall stud or strong support.
8 INST ALLA TION IN EXISTING CONSTRUCTION LA YOUT AND PLANNING The general layout and planning and the component locations are the same for existing construction.
9 4. Be sure tubing hole is centered in sole plate and directly in line with proposed wall inlet cutout. NOTE: If 330 wall inlet is being used refer to Model 330 Wall Inlet Installation on next page. 5. If area is clear, cut an inlet opening in the wall approximately 18" above the floor.
10 MOUNTING PLA TE MOUNTING HOLE (2) ELBOW FIGURE 32 MOUNTING PLA TE INLET FIGURE 33 1. Make cutout according to dimensions in Figure 30. 2. Refer to Figure 31. Break off nail plate at scored line. 3. Refer to Figure 32. Glue elbow to mounting plate, place assembly into cutout, and attach elbow to tubing inside the wall.
11 FLOOR SUB-FLOOR 2 9 / 16 " 3 1 / 16 " INLET EXTENSION FLOOR INLET FRAME MOUNTING BRACKET SEAL FLANGED FITTING FIGURE 36 CUT TO LENGTH EXTENSION SLEEVE FLANGED FITTING MOUNTING BRACKET FLA.
Product specifications subject to change without notice. Printed in U.S.A., Rev. 4/01, Part No. 84912 T wo Y ear Limited W arranty WARRANTY OWNER: NuTone warrants to the original consumer purchaser of.
デバイスNuTone CV352の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
NuTone CV352をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNuTone CV352の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。NuTone CV352の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。NuTone CV352で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
NuTone CV352を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNuTone CV352の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、NuTone CV352に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNuTone CV352デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。