CONFOCAL LASER SCANNING BIOLOGICAL MICROSCOPES FV300 FLUOVIEW.
1 FV300 CONFOCAL LASER SCANNING MICROSCO PERFORMANCE FOR THE PERSONAL USER The FV300 is the ideal choice of laser scanning microscopes for personal users.
2 OPE q e r t y u i o !0 !1 !2 w q Optical fiber for laser introduction w Beam collimator e Polarizer r Dichromatic mirror t Excitation dichromatic mirror y XY galvanometer mirror scanners u Pupil len.
Preset the conditions for image acquisition and loading Storage of Acquisition Settings enables immediate, one-touch recall of all the relevant experimental settings and conditions.
Image tool bar X-Y-Z scanning operations and time- lapse observations both produce multiple images, which can be displayed in sequence simply by clicking the sequential mode button. Channel selection and image zooming are also available on the same menu.
5 X -t Slant Line-t FreeLine-t Y -t Y-Z-t X-Y-t ZoomIn-t X-Z-t X-Y-t X-Y-Z-t ZoomIn-Z-t Patch clamp BX61WI fixed stage upright microscope+translation stage Image acquisition ROI designation Intensity versus time measurement Calcium sparks in isolated cardiac myocyte Dr.
6 The 440nm diode laser can be added for CFP/YFP FRET imaging. A 440nm diode laser is optionally available for CFP/YFP imaging. The 440nm laser line ideally excites CFP, with minimal disturbance to YFP, and is therefore suitable for CFP/YFP FRET experiments.
7 PAPP for FRAP Application PAPP: Programmable Acquisition Protocol Processor Easy, reliable flow of experiments for fluorescence recovery after photobleaching.
8 Multi-point time lapse system High-magnification multi-point time lapse observation of living cells. Wide-ranging specimen observations for improved experiment throughput Use of a motorized XY stage allows the analysis of time lapse changes in many points scattered over a wide area.
9 Tile display Topographic projection Height of 3D structure indicated by color. X-Z Y-Z X-Y-Z X -Z Y -Z Using multiple 3D images to obtain accurate 3D structure analysis.
10 Link with patch clamping data • With PCs linked through a LAN, Physiolink can synchronize electrophysiological and confocal image data simultaneously. • With the same time stamp recorded in the two PCs, it is possible to access and analyze an image and its patch clamping data corresponding to the Physiolink software time scale.
11 Lucifer Yellow: retina ganglion cell TexasRed: dopamine-operated amacrine cell Prof. Shigetada Nakanishi Dept. of Biological Sciences, Kyoto Univ. Faculty of Medicine Applications Gallery Morpholog.
12 Fluorescent Proteins C elegans expressing beta-integrin fused to GFP Dr. Xioping Xhu and Dr. John Plenefisch University of Toledo, Dept. of Biology GFP-labeling of Drosophila adults Expression of DsRed in a zebrafish embryo Extended focus image of 5µmx30 slice Pr.
Fluorescence Dyes and Filters 300 400 500 600 700 BA530RIF BA550RIF BA650RIF BA430-460 BA465-495 BA480-495 BA470-520 BA510-540 BA520-550 BA505-550 BA505-525 BA480-510 BA535-565 BA540-590 BA560-600 BA5.
Objectives for fixed stage upright microscopes (using WI-UCD, WI-DICTHRA) 14 Item Specifications Laser light Visible light laser source Select from the following laser, to mounted on laser combiner so.
● All brands are trademarks or registered trademarks of their respective owners. ● Monitor images are simulated. Specifications are subject to change without any obligation on the part of the manufacturer. This catalog is printed by enviromentally-friendly waterless printing system with soy ink.
デバイスOlympus FV300の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Olympus FV300をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOlympus FV300の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Olympus FV300の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Olympus FV300で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Olympus FV300を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOlympus FV300の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Olympus FV300に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOlympus FV300デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。