MICROSCOPE COMPONENTS GUIDE Choosing The Ideal UIS2 Optics Components For Y our Equipment 2006-11.
The wide range of Olympus components introduced here allows users in such diverse fields as resear ch, inspection and production to take advantage of the quality , flexibility and outstanding optical performance of the UIS2 Optical System.
CONTENTS 2 EYEPIECES/FILAR MICROMETER EYEPIECE --------------------------------- 33 Widefield eyepieces WHN10x, WHN10 x-H, CROSSWHN10x, WH15 x --------------------- 33 Super widefield eyepieces SWH10x.
light between the objective lens and tube lens, allowing the creation of user -specific or task- specific optical systems. T o establish real flexibility with such a system, it is necessary to eliminate the occurrence of coma aberration.
4. Lightening Weight has been r educed to appr oximately 2/3 that of conventional products by using an aluminum objective lens barrel cover . This has the effect of lightening the load on the devices at objective lens up/down, suppressing vibrations by lowering the inertial force at objective lens switching, etc.
5 SYSTEM DIAGRAM 5 6 SHUTTER SHUTTER 5 6 SHUTTER U-AN U-AN360-3 U-AN360IR LG-SF LG-PS2 U-LH100HGAPO U-LH100HG U-LH75XEAPO U-LH100-3 U-LH100L-3 U-LH100IR Super widefield trinocular observation tubes Wi.
6 SYSTEM DIAGRAM MOTORIZED UNIT SYSTEM DIAGRAM BXFM-A SYSTEM DIAGRAM See manual U-D5BDREMC U-D6REMC U-FWO BX-RFAA U-AN360RAF U-AFA1M BX-RLAA U-LH100-3 U-LH100L-3 U-FWR Intermediate tubes (Refer to pag.
7 UIS2/UIS OBJECTIVE LENSES MPL (Plan) FLN-100 BD ■ Objective lens series list ■ Meaning of abbreviations shown on objective lens ■ Objective lens notation ■ Features of objective lens series .
UIS2 OBJECTIVE LENSES 8 M Plan SemiApochr omat MPLFLN series Plan SemiApochromat objective lenses, giving high-level correction for chromatic aberration. The lineup consists of 7 objectiv e lenses ranging from 1.25x to 100x, and secures a W.D. of 1mm or longer.
UIS2 OBJECTIVE LENSES 9 Long WD M Plan SemiApochr omat (WD: Working Distance) LMPLFLN series Long working distance Plan SemiApochromat objective lenses, giving high-level correction for chromatic aberration. Suitable with samples having a height difference and in preventing collision, as the working distance is long.
10 UIS2 OBJECTIVE LENSES Unit: mm M Plan Achr omat MPLN series Plan Achromat objective lenses providing excellent image flatness up to F.N. 22. MPLN 5x 0.10 20.0 36 64 50 4.4 98 MPLN 10x 0.25 10.6 18 80 100 2.2 18 MPLN 20x 0.40 1.3 9 111 200 1.1 6.1 MPLN 50x 0.
UIS2 OBJECTIVE LENSES 11 LCD Long WD M Plan SemiApochr omat LCPLFLN-LCD series Perfect objective lens series for observation of LCD panels and other samples through a glass substrate. Aberration correction matched to the glass thickness is accomplished using a correction ring.
UIS OBJECTIVE LENSES 12 Unit: mm ø 5.6 ø 16.5 ø 20 ø 28 WD=0.9 34.7 38.7 40.1 (44.1) 45 4.5 ø 20.32 36.8 40.7 41.7 (44.7) WD=0.3 45 4.5 ø 8 ø 16.6 ø 20.2 ø 28 ø 20.32 ø 5.3 ø 16.5 ø 20.2 40.7 41.5 (44.65) WD =0.35 45 4.5 ø 20.32 ø 28 36.
13 UIS OBJECTIVE LENSES IR Long WD M Plan SemiApochr omat/IR M Plan SemiApochr omat LMPlan-IR series/MPlan-IR IR objective lenses which compensate for aberrations from visible to near infrared light. Ideal for the observations of semiconductor interiors and the back surface of a chip package as well as CSP bump inspection.
UIS2 OBJECTIVE LENSES 14 M Plan SemiApochr omat BD (BD:Brightfield/Darkfield) MPLFLN-BD series Plan SemiApochromat objective lenses, giving high-level correction for chromatic aberration.
15 UIS2 OBJECTIVE LENSES Screw: W26x0.706 Unit: mm MPLFLN 5xBDP 0.15 12.0 36 95.5 50 4.4 59 50 5.3 59 MPLFLN 10xBDP 0.25 6.5 18 83.3 100 2.2 18 100 2.7 18 MPLFLN 20xBDP 0.40 3.0 9 88.5 200 1.1 6.1 200 1.3 6.1 MPLFLN 50xBDP 0.75 1.0 3.6 100.5 500 0.44 1.
UIS2 OBJECTIVE LENSES 16 Long WD M Plan SemiApochr omat BD LMPLFLN-BD series Long working distance Plan SemiApochromat objective lenses, giving high-level correction for chromatic aberration. Suitable with samples having a height difference and in preventing collision, as the working distance is long.
UIS2 OBJECTIVE LENSES 17 M Plan Achr omat BD MPLN-BD series Plan Achromat objective lenses providing excellent image flatness up to F.N. 22. MPLN 5xBD 0.10 12.0 36 137 50 4.4 98 MPLN 10xBD 0.25 6.5 18 155 100 2.2 18 MPLN 20xBD 0.40 1.3 9 162 200 1.1 6.
18 UIS OBJECTIVE LENSES ø 26 41 42.5 43.2 (44.69) 4.5 WD=0.31 ø 10 ø 23 ø 27 ø 29 ø 32 45 MPlanApo100xBD M Plan Apochr omat BD MPlanApo-BD Highest class Plan Apochromat objective lens that maximize performance in brightfield and darkfield observations.
BXFM frame BXFM-F Widely used system that allows use in combination with fiber illumination, motorized revolving nosepiece and telan lens unit. Can easily be integrated into other equipment. Attach to the equipment by rear bolt mounting screw or pillar mounting hole.
MICROSCOPE SYSTEM BXFM 20 BXFM BXFM-F+BXFM-ILH+BXFM-ILHSPU Accommodates the reflected light brightfield/darkfield and fluorescence illuminators. Weight: 3.
MICROSCOPE SYSTEM BXFM 21 ø 32 169 (Stroke) 19-49 124 84 208 290 20 40 45 106 187 92.5 Specimen surface BXFM-S combination sample BXFM-F+BXFM-ILHS+TR30-2+U-KMAS+U-LH100L-3 Weight: 5.5kg (exclude objective lens) Unit: mm BXFM-S BXFM-F+BXFM-ILHS Compact focusing unit suitable for building into existing equipment.
MICROSCOPE SYSTEM BXFM 22 U-ST Compact stand Weight: 5kg Unit: mm Weight: 1.8kg 106 73 143 88 ø 110 133 ø 32 49 133 20 35 ø 40 130 503 ø 25 Ø 32 214~435 622 350 300 180 º 90 50.5 30 º 250 300 Stands A wide variety of stands are available to suit different applications and purposes.
ILLUMINA TION UNITS 23 Universal r eflected light illuminator BX-URA2 Suitable for observations ranging from brightfield to fluorescence. Six mirror units can be attached to this reflected light illuminator simultaneously. Reflected light illuminator for BF/DF BX-RLA2 ND filters are linked when exchanging between brightfield and darkfield.
ILLUMINA TION UNITS 24 170 (Distance to the light axis) Convex section(2-4) for positioning 3.5 Less than R6 21 82 (Revolving nosepiece relief dimension) 5 5.
LAMP HOUSING & ACCESSORIES 25 Reflected light illuminator for BF U-KMAS Very compact reflected light illuminator with reduced depth. Weight: 1.2kg Unit: mm ø 75 88 198 155 21 64 6 21 Unit name De.
LAMP HOUSING & ACCESSORIES 26 Lamp housings Various different lamp housings are available, for use with different light sources: choose to suit the intended purpose.
LAMP HOUSING & ACCESSORIES 27 31.5 (dimensions for installation) Darkfield light excluding tube which is built into the BX-URA2. (42.5) 21 37.5 ø 59 ø 75 43 Lamp housing accessories For the 100W.
LAMP HOUSING & ACCESSORIES 28 Unit: mm Unit: mm Weight: 1.6kg Weight: 210g LG-PS2* Light source LG-SF Light guide U-DULHA Double lamp house adapter 8 76 235 251 10 10 126 86 130 ø 15 (Light guide mounting position) Groove: Width3, Depth1 10 ø 10.
OBSERV A TION TUBES 29 Weight: 350g ø 60 57.6 • For attachable video camera adapters, refer to video camera adapters system diagram page (pages 5-6). U-TLU Single port tube with lens U-TLUIR Single port tube with lens for IR Widefield trinocular observation tubes Trinocular observation tubes with widefield of view.
30 OBSERV A TION TUBES 117.223 61.981 139.400 88.000 2.837 70.330 149.081 20 ° 0' 0" 42 ° 0' 0" 95.929 101.929 318.527 328.338 337.718 72.200 Super widefield trinocular observation tubes Trinocular observation tubes with super widefield of view.
Intermediate tubes Various accessories for various observation need. 31 INTERMEDIA TE TUBES & ACCESSORIES 45 42 ø 75 ø 70 ø 138 96 42 Unit: mm Weight: 1.3kg U-ECA Magnification changer 2x Provides 1x and 2x intermediate magnifications. Weight: 1.
INTERMEDIA TE TUBES & ACCESSORIES 32 Weight: 1kg U-DP Dual port Use this intermediate tube to divide the light path. Weight: 500g U-DP1xC Dual port 1x Combine with U-DP to obtain a 1x image. Weight: approximately 500g U-EPA2 Eyepoint adjuster Raises eyepoint by 30mm.
EYEPIECES/FILAR MICROMETER EYEPIECE 33 Eyepieces Eyepieces for UIS2 optical system. Filar micr ometer eyepiece U-OSM Used for precise measurement in the field of view. WHN10x Widefield eyepiece WHN10x-H CROSSWHN10x Widefield eyepieces WH15x Widefield eyepiece SWH10x-H MICROSWH10x CROSSSWH10x Super widefield eyepieces (25) 18.
REVOL VING NOSEPIECES U-P4RE Centerable quadruple revolving nosepiece with slider slot for DIC U-P6RE Centerable sextuple revolving nosepiece with slider slot for DIC Weight: 1kg Weight: 1kg 104 (114.4) 38 40 48.2 76.4 ø 102.4 116.5 40 47.2 (125.6) 38 87.
REVOL VING NOSEPIECES JAPAN 2A00002 JAPAN U-D6BDRE U-D6BDRE ø 102.4 40 48.2 34.8 76.4 104 (111.2) 40 48.2 ø 102.4 38 76.4 (114.4) 104 116.5 40 Ø 116.5 (125.6) 38 87.6 47.2 U-D6BDRE W26 ✕ 0.706 W20.32 ✕ 0.706 (4) 4 8 ø 28.2 +0.2 0 ø 30 35 Revolving nosepieces for BF/DF objective lenses Choose from following 3 types.
36 2/3" CCD 1/2" CCD Field of view (F.N.) Projection area Practical field of view (mm) = Projection area (Field Number) Objective lens magnifications 2/3" CCD 1/2" CCD 1/3" CCD U-TV1x-2 1x 11 8 6 U-TV0.63xC 0.63x 17.5 12.7 9.5 U-TV0.
Video camera port This port can be attached directly to the trinocular observation tube as well as to the single port tube with lens. VIDEO CAMERA ADAPTERS 37 U-TV1x-2 Video port 1x 22 ø 60 28 ø 64 Video camera mount adapters Allows attachment to video cameras with C, Bayonet, Sony and F mounts.
MOTORIZED UNITS 38 (169) 84 40 45 41 87 (487) 400 64.8 81.5 211.5 86.2 115 80 108 11.8 12 107 Illuminator cable length: 1.800mm Weight: 5.5kg(exclude objective lens) Illuminator cable length: 1.
MOTORIZED UNITS 39 68.3 190.5 115 U-D5BDREMC Motorized quintuple BD revolving nosepiece with slider slot for DIC U-D6REMC Motorized sextuple revolving nosepiece with slider slot for DIC U-P5REMC Motor.
MOTORIZED UNITS 40 Unit: mm ø 78 R88 147.5 108 135 170.5 148 312.5 9 56 58.2 58.4 14.8 62.5 71 * Consult your Olympus dealer about the motorized focus. Cable length: 2000mm Weight: 3.3kg U-AFA1M Active auto focus unit Weight: 1.0kg U-FWR Motorized reflected filter wheel Accomplish maximum 6 filter position exchange 2000 147.
MOTORIZED UNITS 41 51 77 206 310.5 77 133 341.6 334 56 56 169 92 54 70 4 75.5 82.3 50 91.5 210 70 100 214 104 33.6 3 BXFMA-F Motorized illumination with power focus A motorized microscope unit for integration with your equipment.
DEEP UL TRA VIOLET OBSERV A TION SYSTEM 42 Deep ultraviolet observation system This module adds a deep ultraviolet (248nm) optical system to a general microscope. An ultra-high resolution observation is executed by using an extremely short wavelength ray.
1. Field Number (F.N.) and Practical Field of View The field number (F.N.) is referred to as the diaphragm size of eyepiece in mm unit which defines the image area of specimen. The diaphragm diameter actually seen through eyepiece is known as the practical field of view (F.
• Total magnification on the video monitor: m (ob) =50 × , M (video camera adapter) is 0.5 × from Figure 1 and monitor magnification is 46.2 × from Figure 3. M (monitor observation) = M (ob) × M ( video camera adapter ) × monitor magnification =50 × 0.
9. Aberrations A difference between an ideal image and an actual image that passes through an optical system is called an “ aberration. ” 9.1 Requirements for Ideal Image Formation The following three requirements must be satisfied to form an image with no aberration, or an ideal image.
(4) Field curvature An image plane of an object on a plane perpendicular to an optical axis does not always become a plane perpendicular to the optical axis, but it generally becomes a curved plane.
Specifications are subject to change without any obligation on the part of the manufacturer. Printed in Japan M1606E-1106B • OLYMPUS CORPORATION has obtained ISO9001/14001.
デバイスOlympus Microscopeの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Olympus Microscopeをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOlympus Microscopeの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Olympus Microscopeの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Olympus Microscopeで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Olympus Microscopeを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOlympus Microscopeの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Olympus Microscopeに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOlympus Microscopeデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。