S ingle U se Cannula V S ingle U se Cannula V.
T aper (PR-V435Q) Standard (PR-V416Q) Shor t taper (PR-V418Q) Slit (PR-V427Q) Ball Tip (PR-V223Q) T aper (PR-V434Q) Shor t taper (PR-V414Q) Long taper (PR-V420Q) The V -System is a complete system that integrates O lympus endoscopes and EndoTherapy devices.
Specifications, design and accessories are subject to change without any notice or obligation on the part of the manufacturer. Shinjuku Monolith, 3-1 Nishi-Shinjuku 2-chome, Shinjuku-ku, Tokyo 163-091.
Si ngle U se 3-Lumen E xtraction Balloon V.
B The guidewire and injection lumens are separated to ensure smoother passage of the guidewire. A dditionally , contrast media can be injected without remo ving the guidewire. T wo models are available — one with the injection port located above the balloon and the other with the injection port located below the balloon.
B The guidewire and injection lumens are separated to ensure smoother passage of the guidewire. A dditionally , contrast media can be injected without remo ving the guidewire. T wo models are available — one with the injection port located above the balloon and the other with the injection port located below the balloon.
S pacif ications Model B-V231P-B B-V231P-A Injection port Balloon diameter Sheath Working length Minimum channel size Compatible guidewire Radiopaque band Syringes Below 8.
Single Use Retriev al Basket V Single Use Retriev al Basket V.
Injection port for contrast media facilitates fluoroscopic visualization. S terile single-use design for convenience both before and after procedur es.
An emergency device, this is only to be used in the unlikely event of basket impaction due to an extremely hard calculus. Specifications, design and accessories are subject to change without any notice or obligation on the part of the manufacturer.
S ingle U se 2-Lumen S phincterotome V S ingle U se 3-Lumen S phincterotome V.
Ex ceptional C utting P erformance and Easy , F ast Ex change Capabilit y for Enhanced E f f iciency in ER CP S phincterotomy Distal marking on the sheath for impro ved view field visibility The distal marking on the sheath clearly indicates both the center and cutting position of the knife.
Ex ceptional C utting P erformance and Easy , F ast Ex change Capabilit y for Enhanced E f f iciency in ER CP S phincterotomy T apered tip design for smooth insertion into strictures and the minor pap.
Specifications, design and accessories are subject to change without any notice or obligation on the part of the manufacturer. Shinjuku Monolith, 3-1 Nishi-Shinjuku 2-chome, Shinjuku-ku, Tokyo 163-091.
DISPOSABLE GUIDEWIRE.
An Essential T ool to achieve a N ew Level of Ef f iciency in B iliar y-P ancr eatic P rocedur es. Designed to Enhance the R evolutionar y Exchange C apability of the V -System. 130mm Ring-marker section Spiral-marker section Ring-markers are visible from 50mm to 120mm from the distal end to help determine duct penetration.
An Essential T ool to achieve a N ew Level of Ef f iciency in B iliar y-P ancr eatic P rocedur es. Designed to Enhance the R evolutionar y Exchange C apability of the V -System.
Specifications, design and accessories are subject to change without any notice or obligation on the part of the manufacturer. Shinjuku Monolith, 3-1 Nishi-Shinjuku 2-chome, Shinjuku-ku, Tokyo 163-091.
デバイスOlympus StarTip Vの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Olympus StarTip Vをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOlympus StarTip Vの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Olympus StarTip Vの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Olympus StarTip Vで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Olympus StarTip Vを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOlympus StarTip Vの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Olympus StarTip Vに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOlympus StarTip Vデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。