FPR 200 F lo w Sensor Flow Sensor with St ainless Steel Body Flow Sensor with Polypropylene Body User ’s Guide Shop online at omega.com e-mail: info@omega.
Servicing Nor th America: U.S.A.: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.
Introduction This manual is a service guide produced by the manufacturer . The manual provides specific procedures and/or illustrations for installa- tion, inspection, cleaning and filtration of all Omega FPR 200 flow sensors. When properly followed, these procedures will keep your flow sensor operating dependably for many years.
Installation - Mec hanical 1. The flow sensor has NPT (National Pipe Thread) plumbing con- nections. It is recommended that a paste type pipe sealant be used on these threads. [T eflon tape sealant can be used as long as it is applied in such a way that it will not enter the flow stream.
4. It is recommended that the sensor be placed in such a position that the round access cover can be removed for cleaning and tur- bine servicing. It is also recommended that a union be placed near the sensor to allow easy removal. Note1: The flow sensor is a bi-directional measuring device.
Apply the DC supply voltage directly across the sensor wires. If the LED does illuminate, the load is either: too great of imped- ance or an open circuit. If the LED does not illuminate, the sen- sor's lead wires or circuit are defective. 6. The installation should be complete.
Installation - Electronic (Pulse Output Only) The flow sensor pulse output circuit is a three-wire DC-powered design that transmits a frequency proportional to flow rate. The circuit operates on 5-24 V DC and will consume a maximum of 25 mA from the power supply .
Installation - Electronic (R elay Output Onl y) 1. Connect the red wire from the sensor to the positive terminal of the 12-35 V DC power supply . 2. Connect the black wire from the transmitter to the negative terminal of the 12-35 V DC power supply . 3.
Set P oint Adjustment (Relay Output Only) 1) Adjust the flow rate through the line in which the flow sensor is installed to the rate that corresponds to the desired relay trip point.
1. Relieve pressure in the piping system. 2. Remove the retainer ring that secures the turbine access cover . 3. Remove the access cover with a pliers, taking care not to damage the o-ring seal. 4. Pull out the turbine assembly and the shaft. 5. Inspect the shaft for things that may have wrapped around it.
Mechanical Specifica tions FL OW SENSOR WITH ST AINLESS STEEL BOD Y Maximum pressure: 200 PSI clear cover , 500 PSI SS cover Maximum temperature: 225 º F Measuring range* 1/2" NPT Ported: 0.
ALL VERSIONS WITH 0-5 VDC CIR CUIT Power requirements: 12-35VDC, 20 mA Maximum Current: 30 mA DC Max. T rans. Distance: <200 feet recommended Min. Load Resistance: 1000 Ω Flow rate accuracy: 2% of full scale Repeatability: 0.
Dimension Drawings 1 Dimension with optional clear cover installed 2 Polypropylene version only DIM 1/2" NPTF Port s 3/4" & 1" NPTF Port s A 1.94" (49 mm) 3.06" (78 mm) B 1.13" (29 mm) 1.33" (34 mm) C 2.00" (51 mm) 2.
NOTES: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _.
WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels.
デバイスOmega Engineering FPR 200の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omega Engineering FPR 200をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmega Engineering FPR 200の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omega Engineering FPR 200の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omega Engineering FPR 200で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omega Engineering FPR 200を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmega Engineering FPR 200の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omega Engineering FPR 200に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmega Engineering FPR 200デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。