OpticonメーカーLGZ 7225の使用説明書/サービス説明書
ページ先へ移動 of 87
User’s Manual LGZ 7225 Long Range Handheld CCD Scanner 25-ULGZMU01-01 Keyboard Wedge Interface USB Interface RS232 Interface 8 Olympic Drive Orangeburg, NY 10962 Tel 800.
Content s General Information Unpacking . Opticon Customer Service and Support I n s t a l l a t i o n Default Settings Interface Selection Scanning Modes Beeper Settings Symbology Options Prefix/Suff.
Getting Started General Information The LGZ 7225 CCD Scanner utilizes state-of-the art imaging technology similar to that found in digital cameras, fax machines and video cam corders. The captures an “image” of the bar code and converts it into digital signals that the host computer understands.
LGZ7225 Long Range Handheld CCD Spec 160 g (cable not included) Cable - K/B Wedge Straight 2.0 m Cable - universal type Straight 2.3 m Connector type RJ-45 phone jack connector Case material ABS plastic Cushion material Rubber Electrical Input Voltage 5 VDC r 0.
Default Setting for each barcode shown as below: Code Type Read Checksum Verifacation Checksum Transmission Code ID UPC-A X X X A UPC-E X X X E EAN-13 X X X F EAN-8 X X X FF Code-39 X * Interleaved 2o.
Programming Programming method Manual (Reading special barcode) DOS command through RS-232, Windows configuration program Program upgrade Enabled by built-in flash memory Programmable characteristics .
Programming t he LGZ7225 T o program the LGZ7225 you must scan a series of programming barcode in the correct order . Fold out the back cover of this manual. Y ou will see a table of alphanumeric barcodes, which are used to program the various options presented.
Option Bar Code Option Alphanumeric Entry Interface selection Keyboard W edge RS-232 Wand emulation USB Keyboard/RS-232 Auto detection reserved 00 ഖ 01 02 03 04 05 Back Fold Out Finish barcode Exit .
Interface Selection This decoder buil t -in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, wand emulation, and the latest USB interface. In most of the cases, simply s utilizing the an appropriate cable with a device code will work for a specific interface.
Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The inst allation of the wedge is a fairly simple process without any changes of software or hardware. Keyboard T ype: Select keyb oard type connector of your host computer .
Keyboard wedge Keyboard Layout : The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire.
Keyboard layout USA Belgium Danish France Germ any Italian Portuguese S panish Swedish Switzerland UK Latin American 00 ഖ 01 02 03 04 05 06 07 08 09 10 11 Keyboard speed 0-8 0 : high clock rate 8 : .
Keyboard wedge Caps Lock: By selecting Caps Lock or No Caps Lock , scanner can get Caps Lock status. Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation.
Program Option Bar Code Option Alphanumeric Entry Caps lock Caps lock”ON” Caps lock”OFF” 00 01 ഖ Power-on simulation Disable Enable 00 ഖ 01 Inter-character delay 00-99 msec 00-99 02 ഖ Bl.
RS-232 CTS: Clear T o Send (Hardware Signal) RTS: Request T o Send (Hardware Signal) Xon: T ransmit On (ASCII Code 1 1 16 ) Xoff: T ransmit Off (ASCII Code13 16 ) Flow control: None- The communication only uses TxD and RxD signals without regard for any hardware o r software handshaking protocol.
Program Option Bar Code Option Alphanumeric Entry Flow control None RTS/ CT S Xon/Xoff ACK/NAK 00 ഖ 01 02 03 Inter-character delay 00-99 (msec) 00-99 00 ഖ Block transmission delay 00-99 (10 msec) .
Program Option Bar Code Option Alphanumeric Entry Baud rate 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS 00 01 02 03 04 05 ഖ 06 07 Parity None Odd Even 00 ഖ 01 02 Data b.
W and Emulation Bar/space polarity: High/low - Black will be transmitted as a high voltage level (+5) and space as low level (0V). Low/high - Black will be transmitted as a low voltage level (0V) and space as high level (+5). Initial polarity: Y ou must make sure what is Initial polarity of your wand decode device in stand-by (idle).
W and Emulation Output speed: This setting is same as serial transmission baud rate, and it must be approbated your wand decode resolution. The unit of speed is a width of minimum narrow bar . Margin delay: It is a timer of zone like space zone of barcode label margin.
Reserved 00 ഖ Reserved 00 ഖ Margin delay 00-99 (10 pixel) 00-99 15 ഖ T ransmit delay 00-99 (10 msec) 00-99 30 ഖ Exit 20.
Scan Scanning mode: Good-read off- The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary- The trigger button acts as a switch.
Program Option Bar Code Option Alphanumeric Entry Scanning mode Good-read off Momentary Alternate T imeout off Continue 00 01 ഖ 02 03 04 S tand-by duration 01-99 (second) 00-99 10 ഖ Same barcode d.
Scan Multi field scan: The scanner can be read m any sets of barcode data on the same scanning line at the same time, even if they are different kinds of barcode symbology . Global min./max. code length: Global Minimum and Maximum length can be set to qualify data entry .
Multi field scan Disable Enable 00 ഖ 01 Global min. code length 00-63 00-63 04 ഖ Global max.code length 00-63 04-63 63 ഖ Inverted image scan Disable Enable 00 ഖ 01 CTS trigger Disable Enable 0.
Indication Exit Power on alert: After power-on the scanner it will generate an alert signal to indicate a successful self-test. LED indication: After each successful reading, the LED above the scanner will light up to indicate a good barcode reading.
Program Option Bar Code Option Alphanumeric Entry Power on alert Disable Enable 00 01 ഖ LED indication Disable Enable 00 01 ഖ Buzzer indication Disable Enable 00 01 ഖ Beep loudness 00-07 00-07 07 ഖ Beep tone freq.
UPCA Read: Format Leading Zero Data Digits (1 1 Digits) Check Digit Check-sum transmissi on: By setting Enable , checks sum will be transmitted. T runcate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero.
Check-sum verification Disable Enable 00 01 ഖ Check-sum transmission Disable Enable 00 01 ഖ Max.code length 00-64 00-64 64 ഖ Min.code length 00-64 00-64 01 ഖ T runcate leading 0-15 00-15 00 .
UPCA Supplement dig its: The Supplement digits barcode is the supplemental 2 or 5 characters for WPC code. Format Leading Zero Data Digits (1 1 Digits) Check Digit Supplement Digits 2 or 5 or UCC / EAN 128 T runcate Leading zero: The leading “0” digits of UPCA dat a characters can be truncated when the function is enabled.
UPCE Read: Format Leading Zero Data Digits (6 Digits) Check Digits Check-sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check-sum transmissi on: By setting Enable , checks sum will be transmitted.
UPCE T runcate leading/ending: Refer to T runcate leading/ending of UPCA. Code Id setting: Refer to Code I D setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
T runcate ending 0-15 00-15 00 ഖ Code ID setting 00-ffH ASCII code 00-ffH < E > ഖ Insert group selection 00-44 00-44 00 ഖ Supplement digits None 2 digits 5 digits UCC/EAN 128 Auto detectio.
EAN-13 Read: Format Data Digits (12 Digit s) Check Digits Check-sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check-sum transmissi on: By setting Enable , checks sum will be transmitted.
Check-sum verification Disable Enable 00 01 ഖ Check-sum transmission Disable Enable 00 01 ഖ Max.code length 00-64 00-64 64 ഖ Min.code length 00-64 00-64 01 ഖ T runcate leading 0-15 00-15 00 .
EAN-13 Code Id setting: Refer to Code I D setting of UPCA. Insertion group selecti on: Refer to Insertion group selection of UPCA. Supplement dig its: Format Data Digit s (12 Digits) Check Digits Supp.
Program Option Bar Code Option Alphanumeric Entry Code ID setting 00-ffH ASCII code 00-ffH < F > ഖ Insert group selection 00-44 00-44 00 ഖ Supplement digits None 2 digits 5 digits UCC/EAN 12.
EAN-8 Read: Format Data Digits (7 Digits) Check Digits Check-sum verification: The checksum of EAN-8 is optional and made as the sum of the numerical value of the data digits. Check-sum transmissi on: By setting Enable , checks sum will be transmitted.
Check-sum transmission Disable Enable 00 01 ഖ Max.code length 00-64 00-64 64 ഖ Min.code length 00-64 00-64 01 ഖ T runcate leading 0-15 00-15 00 ഖ T runcate ending 0-15 00-15 00 ഖ Code ID set.
EAN-8 Supplement dig its: Format Data Digits (7 Digits) Check Digits Supplement Digits 2 or 5 or UCC/EAN 128 T runcate Leading zero: Refer to T runcate Leading zero of UPCE.
Code 39 Read: Format Sta rt “ ့ ” Data Digits ( V ariable) Checksum (Optional) End “ ့ ” Check-sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check-sum transmissi on: By setting Enable , checksum and will be transmitted.
Code 39 Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry . If their Max./Min. Code Length is zero, the Global Min./Max. Code Length is in effect. The length is defined as to the actual barcode data length to be sent.
Max. code length 00-64 00-64 00 ഖ Min. code length 00-64 00-64 00 ഖ T runcate leading 0-15 00-15 00 ഖ T runcate ending 0-15 00-15 00 ഖ Code ID setting 00-ffH ASCII code 00-ffH < ഖ > In.
Code 39 Append: This function allows several symbols to be concatenates and be treat as one single data entry . The scanner will not transmit the embedded appending code (space for Code-39). If Enable and other symbols were read again with the appended code, then codes will be transmitted without Code ID, Preamble and Prefix.
Interleaved 2 of 5 Read: Format Data Digits (V ariable) Checksum (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmissi on: By setting Enable , checksum and will be transmitted.
Interleaved 2 of 5 Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/ending: Refer to T runcate leading/ending of UPCA. Code Id setting: Refer to Code I D setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
Code ID setting 00-ffH ASCII code 00-ffH < i > ഖ Insert group selection 00-44 00-44 00 ഖ Exit 46.
Industrial 2 of 5 Read: Format Data Digits (V ariable) Checksum (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/ending: Refer to T runcate leading/ending of UPCA. Code Id setting: Refer to Code I D setting of UPCA.
T runcate leading 0-15 00-15 00 ഖ T runcate ending 0-15 00-15 00 ഖ Code ID setting 00-ffH ASCII code 00-ffH < i > ഖ Insert group selection 00-44 00-44 00 ഖ Exit 48.
Matrix 2 of 5 Eur Read: Format Data Digits (V ariable) Checksum (Optional) Checksum V erification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum T ransmission: By setting Enable , checksum and will be transmitted.
Checksum T ransmission Disable Enable 00 ഖ 01 Max. code length 00-64 00-64 00 ഖ Min. code length 00-64 00-64 00 ഖ T runcate leading 0-15 00-15 00 ഖ T runcate ending 0-15 00-15 .
Codabar Read: Format S tart Data Digits (V ariable) Checksum (Optional) End Checksum V erification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum T ransmission: By setting Enable , checksum and will be transmitted.
Checksum T ransmission Disable Enable 00 ഖ 01 Max. code length 00-64 00-64 00 ഖ Min. code length 00-64 00-64 00 ഖ T runcate leading 0-15 00-15 00 ഖ T runcate ending 0-15 00-15 00 ഖ Code ID s.
Codabar Insertion group selection: Refer to Insertion group selection of UPCA. St art /End type : The Codabar has four pairs of St art/End pattern; you may select one pair to match your application. St art/End T ransmission: Refer to St art/End T ransmission of Code 39.
Code-128 Read: Format Data Digits (V ariable) Checksum (Optional) Checksum V erification: The checksum is made as the sum module 103 of all data digits.
Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/ending: Refer to T runcate leading/ending of UPCA. Code Id setting: Refer to Code I D setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
T runcate leading 0-15 00-15 00 ഖ T runcate ending 0-15 00-15 00 ഖ Code ID setting 00-ffH ASCII code 00-ffH < # > ഖ Insert group selection 00-44 00-44 00 ഖ Format S tandard UCC/EAN-128 0.
Code-93 Read: Format Data Digits (V ariable) Checksum1 (Optional) Checksum2 (Optional) Checksum V erification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum T ransmission: By setting Enable , checksum and will be transmitted.
Checksum T ransmission Disable Enable 00 ഖ 01 Max. code length 00-64 00-64 00 ഖ Min. code length 00-64 00-64 00 ഖ T runcate leading 0-15 00-15 00 ഖ T runcate ending 0-15 00-15 00 ഖ Code ID s.
Code-1 1 Read: Format Data Digits (V ariable) Checksum1 (Optional) Checksum2 (Optional) Checksum V erification: The checksum is presented as the sum module 1 1 of all data digits. Checksum T ransmission: By setting Enable , checksum1 and checksum2 will be transmitted upon your selected checksum verification method.
Checksum T ransmission Disable Enable 00 ഖ 01 Max. code length 00-64 00-64 00 ഖ Min. code length 00-64 00-64 00 ഖ T runcate leading 0-15 00-15 00 ഖ T runcate ending 0-15 00-15 00 ഖ Code ID s.
MSI/plessey Read: Format Data Digits (V ariable) Checksum1 (Optional) Checksum2 (Optional) Checksum V erification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10 , Mod10/10 and Mod 1 1/10 . The checksum1 and checksum2 will be calculated as the sum module 10 or 1 1 of the dat a digits.
Checksum T ransmission Disable Enable 00 ഖ 01 Max. code length 00-64 00-64 00 ഖ Min. code length 00-64 00-64 00 ഖ T runcate leading 0-15 00-15 00 ഖ T runcate ending 0-15 00-15 00 ഖ Code ID s.
UK/plessey Read: Format Data Digits (V ariable) Checksum1+2 (Optional) Checksum V erification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 1 1 of the data digits. Checksum T ransmission: By setting Enable , checksum will be transmitted.
Checksum T ransmission Disable Enable 00 ഖ 01 Max. code length 00-64 00-64 00 ഖ Min. code length 00-64 00-64 00 ഖ T runcate leading 0-15 00-15 00 ഖ T runcate ending 0-15 00-15 00 ഖ Code ID s.
T elepen Read: IA T A (International Air Transport Association). Checksum V erification: The checksum is presented as the sum module 10 or 1 1 of the data digits. Checksum T ransmission: By setting Enable , checksum will be transmitted. Max./Min. code length: Refer to Max.
Max. code length 00-64 00-64 00 ഖ Min. code length 00-64 00-64 00 ഖ T runcate leading 0-15 00-15 00 ഖ T runcate ending 0-15 00-15 00 ഖ Code ID setting 00-ffH ASCII code 00-ffH < S > ഖ .
St andard 2 of 5 Read: Format Data Digits (V ariable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/ending: Refer to T runcate leading/ending of UPCA. Code Id setting: Refer to Code I D setting of UPCA.
T runcate leading 0-15 00-15 00 ഖ T runcate ending 0-15 00-15 00 ഖ Code ID setting 00-ffH ASCII code 00-ffH < i > ഖ Insert group selection 00-44 00-44 00 ഖ Exit 68.
China Post Read: Format Data Digits (V ariable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/ending: Refer to T runcate leading/ending of UPCA. Code Id setting: Refer to Code I D setting of UPCA.
T runcate leading 0-15 00-15 00 ഖ T runcate ending 0-15 00-15 00 ഖ Code ID setting 00-ffH ASCII code 00-ffH < t > ഖ Insert group selection 00-44 01-44 00 ഖ Exit 70.
It alian Pharmacode Read: Format Data Digits (V ariable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/ending: Refer to T runcate leading/ending of UPCA. Code Id setting: Refer to Code I D setting of UPCA.
Min. code length 00-64 00-64 09 ഖ T runcate leading 0-15 00-15 00 ഖ T runcate ending 0-15 00-15 00 ഖ Code ID setting 00-ffH ASCII code 01-ffH < p > ഖ Insert group selection 00-44 00-44 0.
String setting Prefix characters : Up to 22 ASCII characters may be sent before data digits. Pre fi x Data D ig its Suffi x Suffix characters: Up to 22 ASCII characters may be sent after data digit s. Preamble/ Postamble characters: They are appended to the data automatically when each barcode is decoded.
Preamble characters setting None 1-22 characters 00 ഖ 00-ffH ASCII code Postamble characters setting None 1-22 characters 00 ഖ 00-ffH ASCII code Insert G1 characters setting None 1-22 characters 0.
String setting Insert G1/G2/G3/G4 character settin g: The scanner offer 4 positions and 4 characters to insert among the symbol. Example: Barcode “1 2 3 4 5 6”. Output- Barcode “1 2 A B 3 4 C D 5 6”. St e p s : 1) Scan Prog ramming and Insert G1 characters setting barcode.
Insert G3 characters setting None 1-22 characters 00 ഖ 00-ffH ASCII code Insert G4 characters setting None 1-22 characters 00 ഖ 00-ffH ASCII code Exit 76.
T ransmission Preamble transmission : By setting Enable , Preamble will be appended before the data transmitted. Postamble transmission: By setting Enable, Postamble will be appended after the data is transmitted. Insert data group 1-4 position: The scanner offers 4 positions to insert among the symbol.
Insert data group 1 position 00-64 (00: no insertion) 00-64 00 ഖ Insert data group 2 position 00-64 (00: no insertion) 00-64 00 ഖ Insert data group 3 position 00-64 (00: no insertion) 00-64 00 ഖ.
T ransmission Code ID transmission: If your a pplication is needed to transmit Code ID, you must set this to Proprietary ID or AIM ID. Code length transmiss ion: A number of data digit s can be transmitted before the code data when Enable is selected.
Code length transmission Disable Enable 00 ഖ 01 Code name transmission Disable Enable 00 ഖ 01 Case conversion Disable Upper case Lower case *For barcode data only 00 ഖ 01 02 Exit Format of barco.
7HVW&KDUW CODABAR-P ARA CODE-1 1 P ARA CODE-128 P ARA CODE-39 P ARA CODE-93 P ARA EAN-13 P ARA 81.
PDF-417 ST ANDR AD-25 P ARA CODE-16K EAN-8 P ARA INDUSTRIAL-25 P AR A UPCE P ARA 82.
INTERLEA VED-25 P ARA MA TRIX 25 P ARA MSI/PLESSEY P ARA UPCA P ARA UK/PLESSEY P ARA 83.
ASCII Code T able 1RWH )RUNHERDUGZHGJH RQO / + 1XOO 18/ '/( 8S ) 62+ '&.
Parameter Setting List Program Barcode standard p arameter setting list If you wish to display the current configuration of your LGZ7225 , scanner over the host terminal/computer scan the Barcode standard parameter setting list bar code.
Firmware version list If you wish to display the firmware version, scan the Firmware version list. WA RNING : Default value initiali zation If you wish to return the LGZ 7225 to all the factory default settings, scan the Default value initialization bar code.
97 0 A 1 B 2 C 3 D 4 E 5 F 6 7 8 Finish 9 87.
デバイスOpticon LGZ 7225の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Opticon LGZ 7225をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOpticon LGZ 7225の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Opticon LGZ 7225の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Opticon LGZ 7225で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Opticon LGZ 7225を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOpticon LGZ 7225の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Opticon LGZ 7225に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOpticon LGZ 7225デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。