Deluxe Weather Forecaster with Wireless UV Sensor Model: BAR609HGA USER MANUAL © 2005 Oregon Scientific. All rights reserved. 086-003767-011.
EN 1 Deluxe Weather Forecaster with Wireless UV Sensor BAR609HGA USER MANUAL CONTENTS Introduction ................................................................ 2 Product Overview ...................................................... 3 Front View .
EN 2 INTRODUCTION Thank you for selecting the Oregon Scientific TM Deluxe Weather Forecaster with Wireless UV Sensor (BAR609HGA). This device bundles precise time keeping, UV measurement, weather fore.
EN 3 PRODUCT OVERVIEW FRONT VIEW 1. SNOOZE / LIGHT button 2. Weather Forecast & Barometric Area 3. Indoor / Outdoor T emperature & Humidity Area 4. UV Index (UVI) Area 5. Moon Phase 6 Clock / Alarm Area 7. and : increase or decrease setting / activate or deactivate Atomic Clock 8.
EN 4 BACK VIEW 1. W all mount 2. Battery compartment 3. T able stand BAR609HGAmanual-ENG 05/1/18, 7:11 PM 4.
EN 5 THERMO-HYGRO SENSOR (THGR122NX) 1. LCD display 2. LED status indicator 1. W all mount hole 2. RESET 3. Channel number (1 - 3) 4. Battery compartment (Battery compartment cover not shown) BAR609HG.
EN 6 FRONT VIEW (UVN128) 1. Sensor 2. LED indicator BACK VIEW (UVN128) 1. RESET hole 2. Connector for stake apparatus BAR609HGAmanual-ENG 05/1/18, 7:11 PM 6.
EN 7 GETTING ST ARTED BA TTERIES Batteries are not supplied with this product. Y ou will need to purchase the following alkaline batteries: • Main unit 3 x UM-3 / AA 1.5V • Remote sensor 2 x UM-4 / AAA 1.5V • UV sensor 2 x UM-3 / AA 1.5V Insert batteries before first use, matching the polarity as shown in the battery compartment.
EN 8 SWITCH OPTION Channel Channel 1 - 3. If you are using more than one sensor, select a different channel for each sensor . SETUP SENSOR 1. Open the sensor battery compartment with a small Phillips screwdriver. 2. Insert the batteries, matching the polarity as shown in the battery compartment.
EN 9 Wireless ranges can be impacted by a variety of factors such as extremely cold temperatures. Extreme cold may temporarily reduce the effective range between the sensor and the base station.
EN 10 T o force a manual search for Atomic Clock signals, press and hold for 2 seconds. If no signal is found, check the batteries. NOTE If the Atomic Clock signal is received and the hour is incorrect, use the "time zone offset" feature to adjust it to the appropriate time zone.
EN 11 BAROMETER This product tracks barometric pressure changes over the past 24 hours to provide the weather forecast and a trend line showing the direction of barometric change. Barometric changes are measured by the main (indoor) unit. BAROMETRIC TREND SET UNIT AND AL TITUDE Y ou can set the unit of measurement (mb or inHg) and altitude.
EN 12 CLEAR P ARTL Y CLOUDY CLOUDY RAINY Indoor Display DESIGNA TED DISPLA Y Remote Display Channel 1 KINETIC-W AVE ICON Remote Display Channel 2 Remote Display Channel 3 1. Press PRESSURE to select the unit of measurement: mb or inHg. 2. Press and hold PRESSURE for 2 seconds.
EN 13 MINIMUM / MAXIMUM RECORDS T o view temperature, humidity or UV Index current, maximum ( MAX ) and minimum ( MIN ) records: 1. Press CHANNEL to select channel 1-3 or indoor. 2 . Press MEMORY to view the selected channel's records. Press MEMORY to toggle between current, maximum ( MAX ) and minimum ( MIN ) records.
EN 14 4. Y ou can place the sensor in the ground. T o do this, fix the stake into the base of the sensor. Then place the stake into the ground up to the insertion level indicator (see point 1 below) at your desired location. UV SENSOR (UVN128) The UV sensor measures the UV Index.
EN 15 NOTE T o get the most accurate readings, place the sensor in a position that has minimum obstructions (i.e. walls and doors) between it and the main unit. The sensor should be placed in an upright position, away from any shade or shadows that may af fect how accurate the sensor provides readings.
EN 16 as expected (for example, unable to establish radio frequency link with sensor or Atomic Clock). NOTE When you press RESET , all settings will return to default value, and you will lose all stored information. SAFETY AND CARE Clean the product with a slightly damp cloth and alcohol- free, mild detergent.
EN 17 Cannot auto- synch 1. Adjust batteries 2. Press RESET 3. Manually activate Atomic Clock feature T emp Shows "LLL" or "HHH" T emperature is out-of- range Check batteries Check.
EN 18 RELA TIVE HUMIDITY Range 25% to 95% Resolution 1% Memory Minimum / maximum BAROMETER Unit mb or inHg Range 700 to 1050 mb (20.67 to 30.01 inHg) Resolution 1 mb (0.
EN 19 ABOUT OREGON SCIENTIFIC Visit our website (www .oregonscientific.com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children's electronic learning products and games; projection clocks; health and fitness gear; weather stations; and digital and conference phones.
EN 20 • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio / TV technician for help.
Deluxe Weather Forecaster with Wireless UV Sensor Model: BAR609HGA USER MANUAL © 2005 Oregon Scientific. All rights reserved. 086-003767-011.
デバイスOregon Scientific BAR609HGAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Oregon Scientific BAR609HGAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOregon Scientific BAR609HGAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Oregon Scientific BAR609HGAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Oregon Scientific BAR609HGAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Oregon Scientific BAR609HGAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOregon Scientific BAR609HGAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Oregon Scientific BAR609HGAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOregon Scientific BAR609HGAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。