Oregon ScientificメーカーRM998PAの使用説明書/サービス説明書
ページ先へ移動 of 17
NAPOLI Voice Activated Weather Station Model: RM998PA USER MANUAL © 2005 Oregon Scientific. All rights reserved. P/N.: 086-003718-018.
1 EN NAPOLI V oice Activated Weather Station RM998P A USER MANUAL CONTENTS Introduction ................................................................. 2 Product Overview ....................................................... 3 Front View .........
2 EN INTRODUCTION Thank you for selecting the Oregon Scientific TM NAPOLI V oice Activated Weather Station . This device is designed to give you many years of reliable service, including the following.
3 EN PRODUCT OVERVIEW FRONT VIEW 1. Snooze / Light: Activate 8-minute snooze function, or backlight and projector 2. LCD display 3. / : Increase / decrease a setting; activate / deactivate Atomic clock 4. T alk: Enter talking clock training program; activate talking clock after training 5.
4 EN LCD DISPLA Y 1. T ime 2. Offset time zone 3. V oice activated function is ON 4. Battery status 5. AC adaptor is disconnected 6. Calendar 7. Indoor temperature – ° C / ° F 8. Atomic clock reception 9. Soothing sound function is activated 10. Sleep function is activated 1 1.
5 EN GETTING ST ARTED BA TTERIES The main unit uses: • 3 x UM-4 / AAA 1.5V batteries The optional wake-up vibration alarm VR101A (not included in the package) uses: • 2 x UM-3 / AA 1.5V batteries NOTE It is recommended that you use alkaline batteries with this product for longer performance.
6 EN SET CLOCK / CALENDAR Before you can manually set the clock and calendar, you must specify the current time zone you live in and the time format (12- or 24-hour) as follows: 1. Press and hold CLOCK for 2 seconds. The time zone will flash. When an offset hour has been set (e.
7 EN BACKLIGHT Press SNOOZE / LIGHT to activate the backlight for 8 seconds. TEMPERA TURE The clock displays the current indoor temperature. T o choose between ° C / ° F, press the ° C / ° F button to select the setting you want.
8 EN If you want to change the time, sound or volume, continue as follows: 2. Press or to change the soothing sound volume. 3. Press Sound / on / off to confirm. 4. Press and hold Sound / on / off for 2 seconds to enter setting mode. 5. Press or to change the soothing sound.
9 EN TRAIN THE T ALKING CLOCK T o use the talking clock you need to train it to recognise your commands. T o do this, follow the key steps below and listen to the clock’s voice prompts: T ASK ACTION Start training program (1st time training) Press Sound / on / off or T ALK Select user 1 or 2 Press or .
10 EN unless the AC / DC adaptor is used. • Adjust the FOCUS knob to make the image clearer. • Adjust the IMAGE ROT A TION knob to rotate the image clockwise or anti-clockwise. • Manually tilt the projection unit to position the image or press the 180 ° ROT A TION button to reverse the image and turn it upside down.
11 EN RESET THE CLOCK Insert a thin blunt instrument into the hole below RESET to return to the default settings. W ARNINGS This product is designed to give you years of service if handled properly.
12 EN TECHNICAL SPECIFICA TIONS TYPE DESCRIPTION Main Unit Dimensions L x W x H 6.34 x 1.18 x 4.06 inches (161 x 30 x 103 mm) Weight (without battery) 1.52 lbs (235 g) T emperature Unit ° F / ° C Operating Range 32 ° F to +122 ° F (0 ° C to +50 ° C) Indoor Range 23 ° F to +122 ° F (-5 ° C to +50 ° C) Resolution 0.
13 EN Power Main Unit 3 x UM-4 (AAA) 1.5V batteries or 4.5V AC / DC adaptor NOTE It is recommended that you use alkaline batteries with this product for longer performance.
14 EN FCC ST A TEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
15 EN is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.
NAPOLI Voice Activated Weather Station Model: RM998PA USER MANUAL © 2005 Oregon Scientific. All rights reserved. P/N.: 086-003718-018.
デバイスOregon Scientific RM998PAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Oregon Scientific RM998PAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOregon Scientific RM998PAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Oregon Scientific RM998PAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Oregon Scientific RM998PAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Oregon Scientific RM998PAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOregon Scientific RM998PAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Oregon Scientific RM998PAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOregon Scientific RM998PAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。