Oregon ScientificメーカーRMR802の使用説明書/サービス説明書
ページ先へ移動 of 10
E N 1 Solar Clock with Indoor / Outdoor T emperature Model:RMR802 / RMR802A USER MANUAL CONTENTS Overview ..................................................................... 2 Front View ..............................................................
E N 2 OVERVIEW FRONT VIEW 2 1 3 7 9 10 8 1 1 4 5 6 1. Solar panel 2. Remote sensor reception indicator 3. Clock signal reception indicator 4. Indoor temperature 5. MODE : Change settings / display 6. / : Increase / decrease value; activate / deactivate clock reception signal; : toggle between outdoor channels (1-3) 7.
E N 3 1. RESET : Reset unit to default settings 2. EU / UK : Select the nearest radio signal (RMR802 only) 3. °C / °F : Select temperature unit REMOTE SENSOR 1 2 3 4 5 1. LED status indicator 2. Wall mount hole 3. Battery compartment 4. RESET hole 5.
E N 4 1.5 m (5 ft) NO TE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing. SENSOR DATA TRANSMISSION T o search for a sensor: Press and hold + MODE . The sensor reception icon in the remote sensor area shows the status: ICON DESCRIPTION Main unit is searching for sensor(s).
E N 5 RMR802A: • WWVB-60 signal: within 3200km (2000 miles) of Fort Collins Colorado. To enable / disable signal reception: Press and hold to enable or to disable signal reception. NOTE Reception takes 2-10 minutes. If the signal is weak, it can take up to 24 hours to get a valid signal .
E N 6 ICE WARNING If the sensor falls between 3°C to -2 °C (37°F to 28°F), the green LED indicator will flash, and will stop flashing once the temperature is out of this range. NOT E As ice alert is only applicable to channel 1, to prevent flashing of LED, select channel 2 or 3 on outdoor sensor .
E N 7 SPECIFICATIONS TYPE DESCRIPTION MAIN UNIT L x W x H 75 x 33 x 120 mm (2.95 x 1.30 x 4.72 in) Weight 1 12 g (3.95 oz) without battery T emperature range -5°C to 50°C (23°F to 122°F) Signal frequency 433 MHz Power 2 x UM-4 (AAA) 1.5 V batteries REMOTE UNIT (THN132N) L x W x H 96 x 50 x 22 mm (3.
E N 8 FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
E N 9 © 2009 Oregon Scientific. All rights reserved. P/N: 300102249-00001-10.
E N 10 Solar Clock with Indoor / Outdoor Temperature Model:RMR802 / RMR802A USER MANUAL.
デバイスOregon Scientific RMR802の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Oregon Scientific RMR802をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOregon Scientific RMR802の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Oregon Scientific RMR802の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Oregon Scientific RMR802で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Oregon Scientific RMR802を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOregon Scientific RMR802の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Oregon Scientific RMR802に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOregon Scientific RMR802デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。