Orionメーカー8 EQの使用説明書/サービス説明書
ページ先へ移動 of 20
INSTRUCTION MANUAL IN 213 Rev . A 12/02 Providing Exceptional Consumer Optical Products Since 1975 Customer Support (800) 676-1343 E-mail: support@telescope.
2 Figure 1. The Atlas 8 EQ. T ube ring mounting plate T ube ring mounting plate lock knobs (2) Declination setting circle Declination lock le ver Counterweight shaft loc k lev er Counterweight shaft C.
3 T able of Contents 1. Unpacking . . . . . . . . . . . . . . . . . . . . . . . 3 2. P ar ts List . . . . . . . . . . . . . . . . . . . . . . . . 3 3. Assembly . . . . . . . . . . . . . . . . . . . . . . . . 4 4. Balancing the T elescope . . . . . . .
4 3. Assembly Assembly should tak e no more than 30 minutes. Refer to Figure 1 during assembly . Assembling the telescope requires no tools other than the ones provided. 1. Stand the tripod legs upright and spread the legs out as far as they will go .
5 place to keep the hand controller out of the w a y when not in use. Place the “hooks” str ip of n ylon adhesive on the bac k of the hand controller and the “loops” str ip on a tripod leg or on the mount where it will be in a conv eniently reached spot.
6 5. With one hand on the telescope optical tube, loosen the Dec. lock le v er . The telescope should now be ab le to rotate freely about the declination axis.
7 3a). Back the lock ring off by a f ew turns, f or now . Refocus the finder scope on a distant object by threading the objectiv e lens cell in or out of the finderscope body . Precise focusing will be achie ved by f ocusing the finder scope on a bright star .
8 Polar Alignment F or Nor thern Hemisphere obser v ers , appro ximate polar align- ment is achie ved by pointing the mount ’ s r ight ascension axis at the Nor th Star , or P olaris. It lies within 1 ° of the nor th celes- tial pole (NCP), which is an e xtension of the Ear th ’ s rotational axis out into space.
9 quick and easy . T o align the mount using the polar axis finder scope, f ollow these instructions: 1. Approximately polar-align the mount as outlined in the pro- cedure pre viously . 2. Loosen the Dec. lock le ver and rotate the optical tube on the declination axis so that the tube is at a 90 ° to the right ascension axis (Figure 10).
10 hand controller to “ N ” if you liv e in the norther n hemisphere, or “ S ” if you liv e in the souther n hemisphere. When you flip the power s witch, the pow er indicator light on the mount will glow red and the power indicator light on the hand controller will glow green.
Dec. setting circle until the pointer reads e xactly 90 ° .R e - tighten the setting circle thumbscrew . Calibrating the Right Ascension Setting Circle 1. Identify a bright star in the sky near the celestial equator (declination = 0 ° ) and look up its coordinates in a star atlas.
7. Collimating (Aligning The Mirr ors) Collimating is the process of adjusting the mirrors so they are aligned with one another . Y our telescope ’ s optics were aligned at the f actor y , and should not need much adjustment unless the telescope is handled roughly .
13 of the secondar y mirror . This is done by alternately loosening one of the three alignment set screws while tightening the other two , as depicted in Figure 16. The goal is to center the primar y mirror reflection in the secondar y mirror , as in Figure 14d.
14 Star-T esting the T elescope When it is dark, point the telescope at a br ight star and accu- rately center it in the e yepiece ’ s field-of-view . Slowly defocus the image with the f ocusing knob. If the telescope is correctly collimated, the e xpanding disk should be a perfect circle (Figure 19).
15 an hour or more. In the winter , stor ing the telescope outdoors in a shed or garage greatly reduces the amount of time need- ed f or the optics to stabilize. It also is a good idea to k eep the scope cov ered until the Sun sets so the tube does not heat greatly abov e the temperature of the outside air .
16 Important Note: Do not look at the Sun with any optical instrument without a prof essionally made solar filter , or permanent eye dama ge could result.
17 object, the lower its magnitude . Choose an object with a visu- al magnitude of 9 or lower . Many beginners star t with the Messier objects, which represent some of the best and bright- est deep-sky objects, first catalogued about 200 y ears ago by the F rench astronomer Charles Messier .
18 era ’ s shutter is now ready to be opened. A remote shutter release must be used or the image will be b lurred beyond recognition. T r y e xposure times between 1 and 10 seconds, depending upon the brightness of the planet to be pho- tographed and the ISO of the film being used.
19 with hard silicon dio xide, which prev ents the aluminum from o xidizing. These coatings nor mally last through man y y ears of use bef ore requir ing re-coating (which is easily done). T o clean the secondar y mirror , first remov e it from the tele- scope.
20 One-Y ear Limited W arranty This Orion Atlas 8 EQ is warranted against def ects in materials or workmanship for a period of one year from the date of purchase .
デバイスOrion 8 EQの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Orion 8 EQをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOrion 8 EQの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Orion 8 EQの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Orion 8 EQで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Orion 8 EQを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOrion 8 EQの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Orion 8 EQに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOrion 8 EQデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。