Orionメーカー9995の使用説明書/サービス説明書
ページ先へ移動 of 28
INSTRUCTION MANUAL IN 280 Rev . B 02/06 Providing Exceptional Consumer Optical Products Since 1975 Customer Support (800)-676-1343 E-mail: support@telescope.
2 Figure 1. The Sir ius EQ-G mount. T ube ring mounting plate Declination loc k le ver (not shown) F ront opening Declination setting circle Counterweight shaft lock lev er Counterweight lock knob Cou.
3 T able of Contents 1. Unpacking ............................ 3 2. P ar ts List ............................. 3 3. Assembly ............................ 3 4. Attaching a T elescope ................... 4 5. Balancing a T elescope .................. 4 6.
4 the azim uth adjustment knobs on the equator ial mount in order to fit the mount onto the tripod head. 3. Thread the central suppor t shaft up through the tr ipod head and into the bottom of the equatorial mount until tight. Use the upper knob on the central suppor t shaft to do this.
5 hav e either too much or too little counterweight. Remov e counterweight, or add optional counterweights if needed. 3. Retighten the counterweight lock knob. The telescope is now balanced on the right ascension axis. 4. T o balance the telescope on the declination axis, first tight- en the R.
6 T o fi nd Polaris in the sky , look nor th and locate the patter n of the Big Dipper (Figure 6). The tw o stars at the end of the “bowl” of the Big Dipper point right to P olar is . Obser v ers in the Southern Hemisphere aren’t so f or tunate to hav e a br ight star so near the south celestial pole (SCP).
7 Using the P olar Axis Finder Scope The reticle of the polar axis finder scope for the Sirius EQ-G has a tiny star map printed on it that makes precise polar align- ment quic k and easy . T o polar align the mount using the polar axis finder scope, f ollow these instructions: 1.
8 it with the counterweights do wn as pictured in Figure 1. Again, you have to ro tat e t he s cop e i n r igh t a sce nsi on s o t hat th e counterweight shaft is positioned horizontally . Then rotate the scope in declination so it points to where y ou want it near the horizon.
9 1. Speed buttons 2. Directional buttons 3. Set button The dual-axis hand controller is eq uipped wit h a red LED light in each b utton to ind icate ope ratio n. An indiv idual b utton’ s LED will illuminate when the button is pressed. If a b utton combina - tion is entered, all LEDs will ill uminate to in dicate a succe ssful operation.
10 In order to set the guiding speed of y our Sirius EQ-G, use the f ollowing button combinations: •2xsiderealrate: Hol d t he Fast button, then press the Up directional button. •1.75xsiderealrate: Hol d the Fast button, then press the Left directional button.
11 The smaller modular jack on the hand controller (Figure 10) is used f or RS-232 comm unications between the Sirius EQ-G mount and a computer equipped with astronomy softw are like Starr y Night Pro (see “Linking with a Computer”).
12 control of the Sirius EQ-G mount at almost an y step in opera- tion. These controls are lock ed out when the mount is slewing to a n ob jec t. The dir ect ion al bu tton s ar e ver y he lpf ul w hen initially aligning the mount, center ing objects in the ey epiece field of view , and manual guiding.
13 hand controller will lose tr ack of the mount’s position, and the alignment procedure will need to be perf or med again. Keep both the R.A. and Dec. loc k lev ers engaged. 3. T ur n on the pow er switch on the mount 4. The initial screen display ed on the hand controller is the version screen.
14 the alignment procedure must be perf or med again. T o do this, turn the mount’ s power s witch off, then on again. T wo-Star Alignment T wo-star alignment requires only two alignment stars but may produce lesser pointing accuracy than the three-star align - ment.
15 improv ed. T o improve pointing accuracy in another region of the sky , perf or m the P AE function again, this time choosing a bright star in the new region of interest.
16 PEC T raining: See Appendix B for inf or mation LCD/LED T uning: Allows adjustments of the LCD charac - ter contrast, the LCD bac klighting, and the LED backlighting of the pushbuttons . Use the scroll buttons to select which of these you wish to adjust.
17 Note: If the recalled User Object is currently belo w the horizon, the controller will displa y “Below Horizon!! T r y another obj. ” and will automatically return to “Recall Object”. Identifying an Unknown Object The GoT o hand controller has the ability to identify celestial objects that are unknown to you.
18 base, but the hardware version will not change with inter net updates). Note: If the error message “Can not connect to a SynScan hand control” appears on your computer , check all cable con- nections. Also , tr y closing all other computer programs that might be attempting to use the COM por t.
19 Sirius EQ-G GoT o Hand Contr oller Menu T r ee.
20 9. Specifications Mount: German equator ial T ripod: Steel W eight: 30 lbs. Counterweight: 11 lbs. P olar axis latitude adjustment: 10° to 65° P olar axis finder scope: Includ ed, ill uminat or b.
21 Note: The follo wing appendices apply to the Sirius EQ-G with GoT o hand controller only . Appendix A: Enhancing the Pointing Accuracy The Sir ius EQ-G produces pointing accuracy adequate for most applications . If higher accuracy is required, “cone error” calibration ma y be necessar y .
22 8. Without moving the R.A. axis, adjust the azimuth control knobs (Figure 2) to or ient P olar is in the center of the ey e - piece field of view . Adjustment in Dec. axis using the hand controller ma y be necessar y . 9. Loosen the R.A. lock knob and carefully rotate the tele- scope 180° about the R.
23 Figure 19a. Adjust the optical axis offset scre ws this w ay if P olaris moves toward the center of the eyepiece when the tube is pushed as in Figure 18. Figure 19b. Adjust the optical axis offset screws this wa y if Polaris mov es awa y from the center of the ey epiece.
24 Note: Guiding actions are recorded ev en when the PEC train- ing is stopped midway . The PEC + sidereal tracking will not be accurate until a full cycle of the PEC T raining is perf or med. The Sirius EQ-G will emit a “beep” sound and display “Record completed” when the training time is up.
25 Appendix C: RS-232 Connection The Sirius EQ-G mount equipped with the GoT o hand control - ler are designed to rec eive commands sent from a comp uter’ s RS- 232 COM p or t (v ia the co mpute r inter fac e cab le). The han d con trolle r will comm unic ate with th e co mpute r a t 96 00 bits/ sec, no parity , no sto p bi t.
26 Appendix D: Standar d Time Zones of the World.
27.
28 Orion T elescopes & Binoculars 89 Hangar W ay , Watsonville, CA 95076 Customer Support Help Line (800)‑676‑1343 • Day or Evening One-Y ear Limited W arranty This Orion Sirius EQ-G Equator ial Mount is w arranted against defects in materials or workmanship f or a period of one year from the date of purchase .
デバイスOrion 9995の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Orion 9995をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOrion 9995の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Orion 9995の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Orion 9995で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Orion 9995を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOrion 9995の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Orion 9995に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOrion 9995デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。