1 Dear OutBack Customer , Thank you for y our purchase of OutBack pr oducts. W e make ever y e or t to assure our power conversion pr oducts will give you long and reliable service for your r enewable energy system. As with any manufactured device , repairs might be needed due to damage , inappropriate use, or unintentional defect.
2 Disclaimer UNLESS SPECIFICALL Y A GREED T O IN WRITING, OUTBACK POWER SYSTEMS: (a) MAKES NO W ARRANT Y AS TO THE ACCURACY , SUFFICIENCY OR SUIT ABILIT Y OF ANY TECHNICAL OR O THER INFORMA TION PR OVIDED IN ITS MANU ALS OR OTHER DOCUMENT A TION.
3 T ABLE OF C ONTENTS W arranty Summar y..................................................................................................................................................................... 1 Introduction ..............................
4 Introduction The OutBack P ow er Systems FLEXnet DC The FLEXNet DC collects, monitors and recor ds time -based battery amp, watt and volt data for displa y on the OutBack MA TE series of products, allowing for more accurate set point adjustments and pr ecise batter y rechar ging.
5 Think of the input shunts as breaks or junctions in the DC (-) conductor . The current is conducted as though it were a continuous conductor , but the shunts allow the user to monitor the current, providing inf ormation for more accurate batt er y recharg ing.
6 LEDs* 10-postion wiring block 1: BA T - 2: BA T+ 3. Relay 4. Relay 5: C DEVICE SIDE 6: C BA T (-) SIDE 7: B DEVICE SIDE 8: B BA T (-) SIDE 9: A DEVICE SIDE 10: A BA T (-) SIDE • BA T+/- must connect directly to battery terminals of the bank being monitored .
7 The FLEXNet DC package includes: A. FLEXnet DC B. T en-pin wiring plug for shunt, rela y and batter y connections C. Six feet of CA T5 cable for HUB connection D . T en-foot color-coded twisted pair ( TP) cable connects to the batter y E. Thr ee six-f oot, color-coded, twisted pair cables for shunt connections F .
8 • Inser t the FLEXNet DC inside the DC breaker box and through the back side of the breaker bracket; secure with two #6-32 X 3/8 panhead machine screws (included) torqued at 5 t o 8 inch-pounds • Connect all wires to the ten-pin wiring connector .
9 • Black/Whit e twisted pair connects directly to the batter y bank being monitored: Whit e to BA T (-) Black to BA T (+) An appropriate fuse—with a rating of 5 amps or less and greater than 100 .
10 (Installing the FLEXnet DC continued) • Insert the 10-pin connec tor to the wiring block on the back of the FLEXnet DC. • Install the CA T5 cable into the RJ45 jack in the back of the FLEXNet DC. Connect the other end of the cable to the HUB using P ort #2 or higher .
11 FLEXNet DC Measurements The FLEXNet DC can measure and recor d: • V olts for one batt er y bank* • Amps** • KiloWatts • kWhrs removed fr om the batteries • kWhrs returned to the batteries.
12 Logged Data* The previous 128 days of data ar e accessible with the MA TE. The data is logged each night at midnight. Be sure the M A TE’ s clock is set to the correct local time (ref er to your M A TE manual).
13 P rog ramming and Using the MA TE for FLEXNet DC Operations At initial power up , use the MA TE (see pages 17-28) to program: • Batter y Bank 20 Hour Capacity (provided by the manufacturer) in am.
14 FLEXNet DC Modes - Channel A is enabled by default - Each input channel is either enabled or disabled. - A disabled channel will show zero values only . - All enabled channels will run in parallel. - An enabled channel monitors and totals all current owing into or out of the batter y bank through its shunt.
15 The FLEXnet DC ’ s LEDs indicate the SOC by their individual ON/OFF states. Excluding the RED or last LED , when viewing the remaining f our LEDs—GREEN, YELL O W , YELL O W , AND YELL O W— th.
16 Relay L ogic: • Expressed as NO/NC (Normally Open/Normally Closed), basically o /on • May be controlled via the inv er t logic selection from the M A TE.
17 F rom the MAIN M A TE menu, pr ess the <SUM> soft ke y to view a summar y of the system ’ s operation. MA TE Screens DC T oday min/SOC 76% In 347AH 9.
18 DC BA T 12.5V 99% Bat -0.6A 0.000kW Net -4AH 00.7kWH Days Since Full 4.8 The fourth SUM screen shows: • Batter y voltage • The current state- of- charge • Batter y readings show the instantaneous amp , amp hour , kilowatt, and k ilowatt hour gures.
19 The second METER screen shows the accumulated amp hours and kilowatt hours for each shunt. Pr ess the <DOWN> soft key to view the next METER screen. This screen shows the number of remov ed amp hours and watt hours as measured by SHUNT A. P ress the <DO WN> soft ke y to view the SHUNT A charged screen.
20 Pr essing the <DOWN> soft key brings up the SHUNT C charged scr een. Pr essing the <DOWN> soft key leads to the end of the meter menu Pr ess the <ST A TUS> soft k ey to return to the ST A TUS screen.
21 Displaying the kilowatts removed provides the user with more precise ener gy usage information. This gure can be returned to 0 b y pressing the <RESET> soft ke y . P ress the <DOWN> soft key to view the max charged scr een. SHUNT A shows a maximum of 39.
22 ST A TUS/DC/BA T T provides the number of days since the batter y last met its charge parameters . P ress the <RESET> soft ke y to restart the timer . Press the <DOWN> soft key to view the next batter y status screen. batttery min(imum) displays the minimum batter y voltage since it was last reset by the user .
23 lifetime kAH removed shows the t otal k ilowatt amp hours removed fr om the batter y . This is essentially an “ odometer ” for batter y usage. P ress the <DO WN> soft ke y to continue. ST A TUS/DC/BA T T lifetime kAH removed 5 DOWN UP RESET TOP Pr ess the rst two soft ke ys to return to the MAIN menu .
24 Shunt 1 is, by default, enabled or active when the FX is powered up . P ressing the <DIS> soft key disables the rst shunt. Pr essing the <DOWN> soft key leads to the shunt 2 mode and shunt 3 mode screens. These shunts are disabled at power-up and ar e enabled by pressing the <EN> soft key .
25 The return amps screen allows the user t o set the end of charge amps using the <INC> and <DEC> soft keys. Pr ess the <DOWN> soft key to view the batter y charge screen. ADV/DC/CHARGE-------------- return amps DOWN INC DEC TOP ADV/DC/CHARGE--------------- battery charge DOWN INC DEC TOP Pr ess the <CHARGE> soft key.
26 ADV/DC/PAGE 1---------------- choose category ADV BA T SHUNT PG2 Pr ess the <PG2> soft key. Use the low volts scr een and the <INC> and <DEC> soft keys to control the A UX by a low voltage value. P ress the <DOWN> soft key to view the SOC high % screen.
27 T o activate the invert logic func tion, press the <Y ES> soft k ey ; press the <NO> soft key to deactivate it. Press the <DO WN> soft ke y to view the last A UX screen. ADV/DC/AUX/INVER T --------- invert logic DOWN YES NO TOP Change the SOC low % values using the <INC> and <DEC> soft ke ys.
28 Pr essing the <RESET> soft key resets the FLEXnet DC to its factor y default settings. Pr essing the <CLR> soft key clears the data log memor y . ADV/DC/AUX/PAGE 3---------- choose category: PG2 RESET CLR MAIN Pr ess the <PG3> soft key.
29 T echnical Not es Battery Charge F actor (BCF) Some energy is lost both when rechar ging and discharg ing a batter y . The FLEXnet DC compensates for these losses by discounting the amp-hours charg ing the batter y , meaning it doesn ’t count every hour used for rechar ging as actually recharg ing.
30 Revision.2007-08-29 2- Y ear Limited W arranty FLEXnet Pr oducts OutBack P ower Systems , Inc. (“OutBack ”) provides a two year (2) limited warranty (“ Warranty ”) against defects in materials and workmanship for its FLEXnet products (“Pr oducts”) if installed in xed location applications.
31 T o request warranty ser vice, you must contact OutBack T echnical Ser vices at (360) 435-6030 or suppor t@outbackpower .com within the e ective warrant y period. If warrant y ser vice is required , OutBack will issue a Return Material Authorization (RMA) number .
32 T w o Y ear Limited FLEXnet DC W arr anty Registr ation Limited W arranty Registration Complete this form to request a Limited W arranty and return it to: Outback P ower Systems Inc.
900-0093-01-00 REV B European Sales O c e C/ Castelló , 17 08830 - Sant Boi de Llobregat BARCEL ONA, España Phone: (+34) 93.654.9568 Corporate O c e 19009 62nd Av enue NE Arlington, W A USA Phone: (+1) 360.
デバイスOutback Power Systems FLEXnet DCの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Outback Power Systems FLEXnet DCをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOutback Power Systems FLEXnet DCの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Outback Power Systems FLEXnet DCの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Outback Power Systems FLEXnet DCで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Outback Power Systems FLEXnet DCを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOutback Power Systems FLEXnet DCの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Outback Power Systems FLEXnet DCに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOutback Power Systems FLEXnet DCデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。