VQT9737 Model No. AJ- E Operating Instructions Frame Rate Con ver ter Before operating this product, please read the instructions carefully and save this manual for future use.
2 (E) indicates safety information FOR U.K. ONLY This appliance is supplied with a moulded three pin mains plug for your safety and convenience. A 13 amp fuse is fitted in this plug. Should the fuse need to be replaced please ensure that the replacement fuse has a rating of 13 amps and that it is approved by ASTA or BSI to BS1362.
Contents 3 (E) ENGLISH Operating precautions . . . . . . . . . . . . . . . . .3 F eatures . . . . . . . . . . . . . . . . . . . . . . . . . . .4 System configuration . . . . . . . . . . . . . . . . . .4 P ar ts and their functions . . . . . . . . . . .
Features 4 (E) System configuration Frame rate conversion function Using the HD-SDI input signals from a variable frame rate camera (AJ-HDC27F) or DVCPRO HD VTR, this unit con- verts frame rates by taking out only the effective frames of variable frame rate recorded clips, recording them, and play- ing them back.
P arts and their functions 5 (E) ENGLISH 1 POWER switch After the unit ’ s operation has been shut down properly, set this switch to the OFF position. If the power is turned off while the unit is operating, the data may be destroyed or the hard disk drive may malfunction.
P arts and their functions 6 (E) 1 HD SDI IN connector (BNC) The HD SDI signals are supplied to this connector. 2 HD SDI through connector (BNC) The HD SDI input signals are passed straight through the unit and output here. 3 HD SDI OUT connector (BNC) The HD SDI signals are output from this connector.
Basic operations 7 (E) ENGLISH Startup 1. Set the power switch to the ON position. P anasonic AJ-FRC27 Now Booting/ 222 ... 05141501 00:00:00:00 720/60P ST OP > 2. The following message appears on the display panel. 3. When startup is completed normally, the following dis- play appears on the display panel.
Basic operations 8 (E) Recording (contin ued) 1. Check that the HD SDI signals are being input from the variable frame rate camera. 2. To start recording data, press the REC and PLAY keys. (Both the REC and PLAY lamps light.) 3. To stop the data recording, press the STOP key.
Basic operations 9 (E) ENGLISH Shutdown 1. In the MENU mode, press the [ 1 ] (right) key to move the cursor to END (shutdown). 2. Press the SET key. 4.
Menu selection 10 (E) Basic screens 1 and 2 05141501 00:00:00:00 12 35 6 7 1 4 720/60P 2 PLA Y A UT O 1 CLIP ID display The name of the clip currently being output appears here.
Menu selection 11 (E) ENGLISH SETUP screen [CLOCK] <02/04/11 00:00:00> VER screen [VERSION] APP V er .1.02 APP Ver.x.xx Application FRNT Ver.x.xx Front panel (FPGA) PCII Ver.x.xx PCI I/F (FPGA) UPCN Ver.x.xx Format converter (FPGA) DVCC Ver.x.xx DVC control (FPGA) DWNC Ver.
Menu selection 12 (E) HDD screen HDD V er ify ST ART OK? YES NO 1 On this screen, some data is saved into a part of the hard disk drive ’ s memory that is free and then loaded to check that the drive is working properly.
Setup menu 13 (E) ENGLISH Menu item Parameter Description HD PB FMT HD PB RATE 1080/23psf 1080/24psf (Default) 1080/25psf 1080/50i 1080/59i 1080/60i 720/59p 720/60p 24 (Default) 25 30 60 For selecting the output format. <Notes> O 23psf = 23.98psf, 59i = 59.
Setup menu 14 (E) REGEN MODE NORMAL (Default) 24PSync For selecting the time code conversion method. NORMAL: Conversion with no synchronization point (head = 00:00:00:00). 24PSync: With the 25 p output, conversion with the designated syn- chronization point serving as the basic point.
Time code (TC) and user’ s bit (UB) 15 (E) ENGLISH O Recorded clips shot at the 24P frame rate setting must be used. If any other clips are used, the value of the time code which is output will be adversely affected. O Output formats: 1080/25P, 720/25P over 59.
Time code (TC) and user’ s bit (UB) 16 (E) When CONV is selected as the TC REGEN setting, the values of the time code which are output to the display panel, remote controller, SD OUT connector and HD SDI OUT connector may not be the same values in all locations.
Input/output f ormats 17 (E) ENGLISH E-E mode (when the same signals as the input signals are output) O Only format conversion is possible with E-E mode outputs.
T r oubleshooting 18 (E) Indication Action to be taken Data is not recorded properly. When the unit is set to the recording mode with the power on, a problem occurs with the E-E output during recording. O Check that the internal cooling fans are running properly.
Err or displa ys 19 (E) ENGLISH Type of error Cause and remedial action RECORD ERROR This appears when data could not be recorded properly when a recording request was processed. Restart the unit. PLAY ERROR This appears when data could not be played back properly when a playback request was processed.
Specifications 20 (E) Operating temperature: 5 to 35 ˚ C Storage temperature: j 10 to 50 ˚ C Operating humidity: 10% to 80% Storage humidity: 5% to 90% Weight: 15 kg Dimensions: (W k H k D) 210 k 222 k 492 mm Recording time: Min.
ENGLISH 21 (E).
Panasonic Broadcast Europe Panasonic Broadcast Europe Ltd West Forest Gate, Wellington Road, Wokingham, Berkshire RG40 2AQ U.K. Tel: 0118 902 9200 Panasonic Broadcast Europe GmbH Hagenauer Str.
デバイスPanasonic AJ-FRC27Eの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Panasonic AJ-FRC27Eをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPanasonic AJ-FRC27Eの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Panasonic AJ-FRC27Eの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Panasonic AJ-FRC27Eで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Panasonic AJ-FRC27Eを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPanasonic AJ-FRC27Eの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Panasonic AJ-FRC27Eに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPanasonic AJ-FRC27Eデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。