EQ-500 ADJUST ABLE RANGE REFLECTIVE PHO T OELECTRIC SENSOR Long sensing range 2.5 m 194 SERIES Multi-v oltage Amplifier Built-in Multi-v oltage Not affected b y bac kground objects Because it can function with 24 to 240 V A C and 12 to 240 V DC , almost any pow er supply anywhere in the world will do.
195 EQ-500 Con venient terminal block type Cabling enab led by wa y of a ter minal bloc k that eliminates waste. Con venient timer function models An easy to set adjuster with indicator T ypes with an ON-dela y / OFF-delay timer av ailable. OFF-dela y , e.
196 EQ-500 BGS / FGS FUNCTIONS MAKE EVEN THE MOST CHALLENGING SETTINGS POSSIBLE! The BGS function is best suited for the f ollowing case Backgr ound not present When object and backg round are separat.
197 EQ-500 OPTIONS With timer OPTION Designation Description Sensor mounting bracket Foot / back angled mounting bracket Sensor mounting bracket • MS-EQ5-01 Model No. MS-EQ5-01 T wo M5 (length 30 mm 1.181 in ) screws with washers and two nuts are attached.
198 EQ-500 SPECIFICA TIONS T ype 0.2 to 2.5 m 0.656 to 8.202 ft 0.1 to 2.5 m 0.328 to 8.202 ft 0.2 to 1.0 m 0.656 to 3.281 ft 0.1 to 1.0 m 0.328 to 3.281 ft 0.2 to 2.5 m 0.656 to 8.202 ft 0.1 to 2.5 m 0.328 to 8.202 ft 0.2 to 1.0 m 0.656 to 3.281 ft 0.
199 EQ-500 I/O CIRCUIT AND WIRING DIA GRAMS I/O circuit diagram T erminal arrangement diagram EQ-51 1 ( T ) EQ-512 ( T ) EQ-501 ( T ) EQ-502 ( T ) I/O circuit diagram T erminal arrangement diagram D Tr 1 12 to 24 V DC 10 % Sensor circuit Z D1 Load Load Output (NPN) 0 V V Tr 2 Z D2 Output (PNP) 100 mA max.
200 EQ-500 SENSING CHARA CTERISTICS (TYPICAL) Sensing fields • Setting distance: 0.5 m 1.640 ft This curve shows the characteristics with the maximum sensing range set to 1 m 3.281 ft , with white non- glossy paper (200 200 mm 7.874 7.874 in ).
201 EQ-500 PRECA UTIONS FOR PROPER USE P art description Multi-volta ge type (L-ON / D-ON mode only) DC-volta ge type Description Operation mode s witch Detection-ON mode is obtained when the switch is turned fully clockwise (L side). Detection-OFF mode is obtained when the switch is turned fully counterclockwise (D side).
202 EQ-500 PRECA UTIONS FOR PROPER USE Time chart Timer function (EQ-5 T only) Operation Sensing condition ON OFF ON OFF ON ON OFF OFF ON ON OFF OFF ON OFF ON OFF Timer period: T = 0.
203 EQ-500 DIMENSIONS (Unit: mm in ) Sensor Notes: 1) The operation mode switch of the DC-voltage type is the DIP switch. 2) EQ-5 T does not incorporate those. 6.5 0.256 26 1.024 Assembly dimensions with sensor mounting bracket MS-EQ5-01 (Optional) (Foot angled mounting) 68 2.
デバイスPanasonic EQ-500 Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Panasonic EQ-500 Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPanasonic EQ-500 Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Panasonic EQ-500 Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Panasonic EQ-500 Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Panasonic EQ-500 Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPanasonic EQ-500 Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Panasonic EQ-500 Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPanasonic EQ-500 Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。