IPD4-A2-GZ4 0-00 February 2005 1 4000E IP Broadband Loop Carrier Instal lation Instr uction s Document Number IPD4- A2-GZ40-00 February 20 05 Contents Software and Firmwa re Licens e Agreement ................... ............. ................... ... 1 Introduc tion .
2 Febru ary 2005 IPD4-A2-GZ40-00 derivat ives obtai ned from t he Software, i ncludin g any co py of eith er . If yo u have executed a separate written agre ement cover ing the Softw are supp lied to you under thi s purchas e, such separate written a greement sh all gove rn.
IPD4-A2-GZ4 0-00 February 2005 3 9. Upon such term ination, t he Licensee shall r efrain fro m any fur ther use of t he Software and destroy the orig inal and all copies of the Soft ware in the possessi on of Licens ee togethe r with all documen tation and related m aterials.
4 Febru ary 2005 IPD4-A2-GZ40-00 2 – Rack Mount Brac kets (eithe r 19" or 23 ", as order ed) 10 – #6 Ph illips Bracket S crews 8 – #10 Phillips Rack Scr ews 8 – #12 Phillips Rack Scr ews If there is visib le damage, do no t attempt to conn ect the device.
IPD4-A2-GZ4 0-00 February 2005 5 ,QVWDOO DWLRQ LQD5D FN Using a Phi llips Screwdri ver , attach the two [2] provided r ack mount bra ckets to the sides o f the 4000E with eigh t [8] of the te n [10] prov ided brac ket screws.
6 Febru ary 2005 IPD4-A2-GZ40-00 Installing Y our Management Module A managem ent mod ule provi des the functi onal con trol for the 4000E BL C; the 4000E ca nnot funct ion withou t one. The re are sev eral different m odels avai lable for purcha se. Refer to www .
IPD4-A2-GZ4 0-00 February 2005 7 3. Slide the Manag ement Modu le Firml y into the Chas sis. Tighten the faste ning screws on the manage ment mo dule face plate.
8 Febru ary 2005 IPD4-A2-GZ40-00 Proc edure 1. Select a Slot for Instal lation. Although the 4000E is factor y shipped with Slot 1 open, in terface m odules may b e installed in any s lot, 1–4. 2. Align the inter face mod ule with the s lot modul e guides.
IPD4-A2-GZ4 0-00 February 2005 9 Powering Up Y our 4000E BLC CAUTION: T urn your DC power so urce(s) OFF until you have complete d connec tion of the 400 0E as outli ned in the following section s. Do not oper ate the 400 0E withou t a ground connecti on.
10 Febru ary 2005 IPD4-A2-GZ40-00 4. Select a terminal bloc k. Using a Phill ips Screwdri ver , remove the upper screw from the c hosen te rminal blo ck (label ed "+" o n the chass is).
IPD4-A2-GZ4 0-00 February 2005 11 5. Remove the right-hand screw (labeled " –") from the same terminal bloc k. Slide the ring terminal of your NEGA TIVE l ead aroun d the shaft of t he screw an d insert the screw into the same "–" termina l from which i t was remove d.
12 Febru ary 2005 IPD4-A2-GZ40-00 Uplink Connections No config uration is necessar y for Uplink In terface Mod ules (UIM s) or Med ia Interfac e Modules ( MIMs) ins talled on the managem ent modul e in your 40 00E to operate a t default s ettings.
IPD4-A2-GZ4 0-00 February 2005 13 the A con nectors pr ovide th e subcrib er connect ions fo r ports 1-12 and the B conne ctors p rovide the subscrib er conne ction s for ports 13-24.
14 Febru ary 2005 IPD4-A2-GZ40-00 4. Pull the hoo k-and-lo op fastener strap upward, ma king su re that it is snug again st the connec tor , the n pull the strap ba ck down, such that the hook-an d-loop f astener l ayers st ick to on e anoth er across th e top of the conne ctor .
IPD4-A2-GZ4 0-00 February 2005 15 Securing the Conn ecting Cables Positio n all co nnecting cables s uch that they will no t becom e a tripp ing haza rd or pull loo se from the chassis; s ecure with cable ti es or hook -and-loop fastener stra ps.
16 Febru ary 2005 IPD4-A2-GZ40-00 Fan Module The 4000 E fan modu le is in stall ed vertic ally to th e right of the interf ace modu le slots. It comes pre-ins talled an d should not be r emoved unless it is b eing repla ced.
IPD4-A2-GZ4 0-00 February 2005 17 Specifications Product Documentation Online Comple te docume ntation for P aradyne products i s availa ble at www .paradyne.com . Select Su pport → T e chnical Manuals . T o or der a paper copy of a Paradyne document , or to speak with a sa les represent ative, pleas e call 1- 727-530-200 0.
18 Febru ary 2005 IPD4-A2-GZ40-00 Important Safety Instructions 1. Read and follow all warning no tices and inst ructions mar ked on the product or include d in the ma nual. 2. Do not attempt to service this prod uct you rself, as opening or removing cover s may exp ose you t o dangero us high vol tage point s or other risks.
IPD4-A2-GZ4 0-00 February 2005 19 — Never to uch uninsul ated telep hone wire s or termi nals unles s the telephone line has been disco nnected a t the networ k interfac e. — Use cauti on when in stallin g or modi fying teleph one lines . — Avoid usin g a telepho ne (other than a c ordless ty pe) durin g an elec trical storm.
20 Febru ary 2005 IPD4-A2-GZ40-00 W arranty , Sales, Ser vice, and T raining Inform ation Contact y our local sales repre sentativ e, service repr esentati ve, or dis tributor directl y for any he lp needed.
デバイスParadyne 4000Eの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Paradyne 4000Eをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはParadyne 4000Eの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Paradyne 4000Eの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Paradyne 4000Eで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Paradyne 4000Eを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はParadyne 4000Eの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Paradyne 4000Eに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちParadyne 4000Eデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。