USER MANUAL MODEL 1008 Ultra-Miniature, High Speed, Multipoint DB-9 Short Range Modem SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www .
1.0 W ARRANTY INFORMA TION Patton Electronics warrants all Model 1008 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.
2.0 GENERAL INFORMA TION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Y ear parts and labor .
T o access the Model 1008’s internal PC boards, insert a small flat- blade screwdriver between the connector and the lip of the case and twist gently as shown in Figure 3 (below). Both DIP switch S1 and S2 are marked with individual switch numbers 1 thru 4.
3.1.3 DIP SWITCH S2 SETTINGS DIP switch S2 is used to configure carrier control, RTS/CTS delay and communication protocol. The summary table below shows the factory default settings for switch S2. Following the summary table is a detailed description of each individual switch.
4.0 INST ALLA TION Once the Model 1008 is properly configured, it is ready to connect to your system. This section tells you how to properly connect the Model 1008 to the twisted pair and EIA/TIA-574 interfaces, and how to operate the Model 1008.
7. When you finish connecting the wires to the terminal block, the assembly should resemble the diagram below: 8. Place the 2 halves of the strain relief assembly on either side of the telephone wire and press together very lightly . Slide the assembly so that it is about 2 inches from the terminal posts and press together firmly .
When connecting two Model 1008s, it is necessary to use a crossover cable. The diagrams below show how a crossover cable should be constructed for the following environments: 4-wire RJ-1 1, 4-wire RJ-45, 2-wire RJ-1 1 or 2-wire RJ-45.
Figure 6 (below) shows how to wire the two-pair cables properly for a Model 1008 daisy chain topology . Note that the ground connection is not needed. 4.3 CONNECTION TO THE EIA/TIA-574 INTERF ACE The Model 1008 is designed to plug directly into the DB-9 serial port of an EIA/TIA-574 DTE device (PC, laptop, host).
APPENDIX B P A TTON MODEL 1008 EIA/TIA-574 INTERF ACE DB-9 SIGNAL 1 -----------------CD 2 -----------------RD 3 -----------------TD 4 -----------------DTR 5 -----------------SG/FG 6 -----------------D.
デバイスPatton electronic 1008の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Patton electronic 1008をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPatton electronic 1008の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Patton electronic 1008の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Patton electronic 1008で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Patton electronic 1008を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPatton electronic 1008の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Patton electronic 1008に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPatton electronic 1008デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。