USE R MANUA L Model 2121/2135 C Ethernet Micro-Bridge SALES OFFIC E (301) 975-100 0 TECHNICAL SUPPOR T (301) 975-100 7 http://www.patton.co m Part# 07M2121- A Doc# 083051U A Revised 09/06/0 0 An ISO-9.
1.0 WARRANTY INFORMATION Patton Electronics warrants all Model 2121/2135C components t o be free from defects, and wil l — at our optio n — repair or replace th e product should it fail within one year from the first date of shipment .
3 2.0 GENERAL INFORMATIO N Thank you for your purchase of this Patton Electronics product . This product has been thoroughly inspected and tested and is warran t - ed for One Year parts and labor.
For example, the customer site is assigned the addresse s 192.168.1.0/24 through 192.168.1.1/24. The addres s 192.168.1.1/24 is also the default gateway for the remote ne t - work. The above settings remove any routing/forwarding inte l - ligence from the CPE.
7 4.3 POWER CONNECTIO N The Model 2121/2135C offers either an AC or DC power su p - ply. The 2121/2135C provides a strap selectable power supply . 4.3.1 AC Power Supply (100-240VAC ) The Model 2121/2135C uses a 5VDC, 2A universal input 100 - 240VAC, power supply (center pin is +5V).
Power-up 2121 via DB-15 Connector on Pin 1 5 Place strap position 1 and 2 on J3 for DC power supply. Se e figure 6 below . Power-up 2135C via M/34 Connector on Pin K K Place strap position 1 and 2 on J3 for DC power supply . See figure 6 below . Power-up 2121 via DB-15 Connector on Pin 1 4 Place strap position 3 and 4 on J3 for DC power supply.
1 1 5.1.2 LED Description s The status LED blinks yellow from one to eleven times t o indicate system status. Each pulse pattern is separated by a 2 second "off " period. Greater pulse patterns have higher priorit y (buffer saturation has greater priority than an empty MAC table).
1 3 1 4 TXD- Trasmit data LED (green) blinks to indicate data trans i - tions and remains OFF when no data is transmitted (idle) . RXD - Received data LED (green) blinks to indicate data tra n - sitions and remains OFF when no data is received (idle) .
1 5 APPENDIX B PATTON ELECTRONICS MODEL 2135C SPECIFICATION S LAN Connection: RJ-45, 10Base T , 802.3 Ethernet sup - ported by Transparent LAN bridging DTE connection: M34 connector, V.
1 7 1 8 APPENDIX C 2121/2135C FACTORY REPLACEMENT PARTS Part # Descriptio n 07M2121/2135C........2121/2135C User Manua l 0805DCUI..................100-250 VAC Universal Power Suppl y APPENDIX D 10Base.
1 9 2 0 APPENDIX E X.21 T erminal Interface Pin Assignmen t (DB-15 Male Connector) Pin # Signa l 1 Frame GN D 2 Transmilt A 3 Control A 4 Receive A 5 Indication A 6 Signal Timing A 8 Signal GN D 9 Transmit B 10 Control B 1 1 Receive B 12 Indication B 13 Signal Timing B 14 DC Power (+5VDC ) 15 DC Power (+5VDC ) APPENDIX F V.
2 1 APPENDIX G POWER SUPPLY INTERFAC E Via 5VDC power jack (J1 ) Center Pin: +5VDC @ 500 mA minimu n Outer Barrel: Groun d.
デバイスPatton electronic 2135Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Patton electronic 2135Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPatton electronic 2135Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Patton electronic 2135Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Patton electronic 2135Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Patton electronic 2135Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPatton electronic 2135Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Patton electronic 2135Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPatton electronic 2135Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。