USER MANUAL MODEL 2703-X21 G.703/E1 Digital Modem SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www .patton.com Part# 07M2703-X21-C Doc# 031 1 1 1UC Revised 6/19/98 CERTIFIED An .
1.0 W ARRANTY INFORMA TION Patton Electronics warrants all Model 2703-X21 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.
Switch Set S1 The configuration switches on S1 set clocking, rate adaptation, loopback enable, and data invert. The default settings are summarized in the table below . S1-1: Master/Slave Clock The setting for switch S1-1 determines whether the Model 2703- X21 provides the master clock, or is slaved to another clock source.
S1-2 and S1-3: Rate Adaptation Switches S1-2 and S1-3 are set in combination to allow the Model 2703-X21 to adapt to terminal devices running at data rates of less than 2.048 Mbps (The network rate remains 2.048 Mbps regardless of the terminal rate adaptation setting).
LK1: 75 Ohm T ransmit Shield-to-Ground Connection This setting determines whether the shield of the 75 Ohm (coax) transmit cable is connected to earth ground. This connection must be made when operating in 75 Ohm (unbalanced) mode. Conversely , this connection must not be made when operating in 120 Ohm (balanced) mode.
LK5: Configuration Auto-Sense This setting determines whether the host can automatically sense the configuration of the Applique. The operation of the Applique is not affected by this jumper setting. Auto-sense should be enabled when operating in 75 Ohm (unbalanced) mode.
4.0 INST ALLA TION Once the Model 2703-X21 is properly configured, it is ready to connect to your system. This section tells you how to properly connect the Model 2703-X21 to the G.703 network and terminal device interfaces. 4.1 CONNECTION TO THE G.703 NETWORK The Model 2703-X21 supports 2.
5.0 OPERA TION Once the Model 2703-X21 is properly configured and installed, it should operate transparently . This sections describes power-up, reading the LED status monitors, and using the built-in loopback test modes. 5.1 POWER-UP T o apply power to the Model 2703-X21, first be sure that you have read Section 3.
APPENDIX B MODEL 2703-X21 PIN CONFIGURA TIONS APPENDIX A P A TTON MODEL 2703 SPECIFICA TIONS Network Interface: G.703 Network Rate: 2.048 Mbps Network Connectors: T wo BNC (75 Ohm) and one modular RJ-45 connector (120 Ohm) T erminal Interface: X.21 on female DB-15 connector T erminal Rate: 2.
APPENDIX C F ACTOR Y P ARTS AND ACCESSORIES C-1 Basic Standalone Units The Patton Model 2703-X21 standalone digital modem is available in three versions, depending upon the power supply installed. The Standard and Universal Interface versions are supplied with a power cord, which must be specified in the model number when ordering .
デバイスPatton electronic 2703-X21の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Patton electronic 2703-X21をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPatton electronic 2703-X21の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Patton electronic 2703-X21の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Patton electronic 2703-X21で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Patton electronic 2703-X21を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPatton electronic 2703-X21の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Patton electronic 2703-X21に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPatton electronic 2703-X21デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。