USER MANU AL MODELS IM1/K and IM2RC/K G.703/G.704 QuikConnect™ and Rear Card Modules SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www .
1 T ABLE OF CONTENTS SECTION P AGE 1.0 W arranty Information .............................................................2 1.1 W arranty Statement 1.2 Radio and TV Interference 1.3 CE and T elecommunication Approvals 1.4 Service Information 2.0 General Information .
3 1.2 RADIO AND TV INTERFERENCE The Models IM1/K and IM2RC/K (K Module) generate and use radio frequency energy , and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television reception.
3.0 TYPICAL APPLICA TION The K Module can be deployed in one of two applications: G.703/G.704 Network T ermination (nx64kpbs to 2.048Mbps), and G.703/G.
3.2 NETWORK EXTENSION APPLICA TION Network Extension mode is used to extend nx64 -2.048Mbps G.703/G.704 service across a DSL link, providing an nx64 G.703/G.704 link at the remote site. T ransmitter clocking is derived from the G.703/G.704 network, and transmitted over the baseband modem link (refer to Figure 2, below).
9 10 Switch S1-3 : Clear Channel Mode When S1-3 is at Off position, the K Module is running in G.703 clear channel mode. When S1-3 is at On position, the K Module is run- ning in G.704 framed mode. When the K Module is set to framed mode, channel 0 will be used to pass G.
12 11 5 5 . . 0 0 I I N N S S T T A A L L L L A A T T I I O O N N This section describes how to install the IM1/K and IM2RC/K mod- ules into your mDSL modems. Please refer to the section in this manu- al that describes your unit. 5.1 Installing the IM1/K The QuickConnect™ interface on the NetLink Modems are inter- changeable Modules.
13 14 5.3 MAKING INTERF ACE CONNECTIONS The Patton K Module may be connected to G.703/G.704 ports using a single 120 ohm RJ-48C or a dual 75 ohm coax (BNC). The Patton K Module rear panels and the location of these connectors are show below in Figure 4.
15 6 6 . . 0 0 O O P P E E R R A A T T I I O O N N Once the Patton K Module is installed and configured, it should operate transparently . Please refer to the base unit (i.e. Model 1095) user manual for instructions on how to read the front panel LEDs, per- form diagnostics, monitor system status, and connect to the DSL line port.
17 18 A A P P P P E E N N D D I I X X B B P A TTON K MODULE CABLE RECOMMENDA TIONS All Patton Electronics Company Baseband Modems, CSU/DSUs and Short Range Modem are tested to the distances published .
A A P P P P E E N N D D I I X X E E P A TTON K MODULE JUMPER SETTINGS Figure C (below) shows the top view of the IM1/K printed circuit board (PCB) and the location of the jumpers. Figure D (below) shows the top view of the IM2RC/K printed circuit board (PCB) and the location of the jumpers.
デバイスPatton electronic IM2RC/Kの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Patton electronic IM2RC/Kをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPatton electronic IM2RC/Kの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Patton electronic IM2RC/Kの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Patton electronic IM2RC/Kで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Patton electronic IM2RC/Kを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPatton electronic IM2RC/Kの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Patton electronic IM2RC/Kに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPatton electronic IM2RC/Kデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。