® Installation/Operation IRD/ERD2000 Series Receiver C1506M (3/00) Pelco • 300 W . Pontiac Way , Clovis • CA 93612-5699 USA • Pelco Online @ www.
[ 2 ] Pelco Manual C1506M (3/00) Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
Pelco Manual C1506M (3/00) [ 3 ] DESCRIPTION The IRD/ERD2000 Series Receiver operates Pelco’s fixed speed pan/tilts and domes. The receiver works with standard and extended Coaxitron ® controllers, including the CM6700/7500/8500/ 9500, KBD9000, MPT9000/9008/9500, and MX4000.
[ 4 ] Pelco Manual C1506M (3/00) ERD2200 WIRING ERD2200 Power Connections ENCLOSURE POWER OUT L L N N 115V 230V 115V POWER SELECTOR SWITCH GROUND STUD POWER TERMINALS MAIN FUSE ENCLOSURE FUSE MAIN POWER IN 1. Fuses are installed for 1 15 V AC operation.
Pelco Manual C1506M (3/00) [ 5 ] 6. Connect the pan/tilt controls (up, down, left, right, and common). 7. Connect the camera power. If your camera uses 24 V AC, connect the camera to the CAM PWR connector on the front of the re- ceiver . The camera’s power must not exceed 5 vA.
[ 6 ] Pelco Manual C1506M (3/00) IRD2024 WIRING Front View of Receiver 24V AC P AN/TILT CAM PWR I F Z C LENS AUX1 AUX2 5V CN N C O PWR CX IN OUT VIDEO TLC CC ~ + Rear View of Receiver 1. Connect power to the 24 V AC INPUT connector on the rear of the receiver .
Pelco Manual C1506M (3/00) [ 7 ] OPERA TION When power is applied to the receiver , the green PWR LED on the receiver lights. Whenever the receiver gets a valid Coaxitron control signal, the green CX LED blinks.
[ 8 ] Pelco Manual C1506M (3/00) FUSE REPLACEMENT IRD2024 Lens/Auxiliary Fuse – A 500 mA fuse protects the LENS and AUX 1 outputs. Remove the cover of the receiver to check the fuse. ERD2200 Main Fuse – The main fuse protects the pan/tilt output when 24 V AC pan/tilt operation is selected.
Pelco Manual C1506M (3/00) [ 9 ] Wire Gauge T able A 24 V AC Wiring Distances T able The following are the recommended maximum wire distances (transformer to load) for 24 V AC applica- tions and are calculated with a 10-percent voltage drop. (T en percent is generally the maximum allowable voltage drop for AC-powered devices.
[ 10 ] Pelco Manual C1506M (3/00) SPECIFICA TIONS ERD2200 ELECTRICAL Input V oltage: 1 15/230 VAC, 50/60 Hz Output V oltage Camera: 24 V AC (or 115/230 V AC if using enclosure power) Lens: 8 VDC Pan/T.
Pelco Manual C1506M (3/00) [ 11 ].
WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Three years on Genex ® Series (multiplexers, server, and keyboard).
デバイスPelco C1506Mの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pelco C1506Mをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPelco C1506Mの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pelco C1506Mの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pelco C1506Mで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pelco C1506Mを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPelco C1506Mの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pelco C1506Mに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPelco C1506Mデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。