INST ALLA TION TW3000P Series Passive Multi-Channel V ideo T ransceivers C1662M-A (1/06).
2 C1662M-A (1/06) Description The TW3000 Series multi-channel video transceivers can transmit multiple video signals over unshielded twisted pair (UTP) cable. The receivers are passive and require no power . The transceivers are available with 8, 16, or 32 channels and can be mounted into an industry standard 19-inch (48.
C1662M-A (1/06) 3 BACK VIEW Figure 1. Back View of TW3008P , TW3016P , TW3032P Rack Ears: Allow mounting into an industry standard 19-inch wide equipment rack. Thumbscrews: Allow back panels to be removed. Panel with Connectors: The TW3008P and TW3016P have one blank panel.
4 C1662M-A (1/06) Installation Make sure all parts are present for the units. TW3008P 4 Rack mount screws, 10-32 x 0.750-inch, Phillips, pan head (U.S.) 4 Rack mount screws, M6 x 1, 20 mm 4W ashers 2 Screw T erminal Connectors TW3016P 4 Rack mount screws, 10-32 x 0.
C1662M-A (1/06) 5 MOUNTING The TW3008P , TW3016P , and TW3032P transceivers are 1 RU (1.75”) high and are supplied with the necessary parts for mounting into an industry standard 19-inch (48.26 cm) wide equipment rack. The units can also be placed on a fl at surface, such as a shelf.
6 C1662M-A (1/06) APPLICATIONS Figures 3-6 show how to use the transceivers in various applications. Always connect + to + and - to - . The TW3032P is used as an example in Figures 3-6. T able A shows the distance in feet with coaxitron or video only when using a particular type of Cat cable.
C1662M-A (1/06) 7 Figure 4. Connecting a UTP Camera to a UTP Receiver NOTE: UTP cameras have a 10-pin RJ-45 connector. Standard RJ-45 connectors have 8 pins.
8 C1662M-A (1/06) Figure 6. Coaxitron PTZ Control 12 3 45 678 9 1 0 1 1 1 2 1 3 1 4 1 5 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 TW3032P UTP VIDEO MONITOR SPECTRA COAXITRON + - + - VC-UTP BO.
C1662M-A (1/06) 9 Service REPLACING A BACK PANEL Y ou can replace a blank back panel or a back panel with connectors easily . Figure 7 shows a blank panel being removed after the two thumbscrews are loosened. The panels with connectors can be removed the same way.
10 C1662M-A (1/06) Specifications ELECTRICAL Power Source No power required Wire T ype Unshielded twisted pair (24 AWG maximum) Wire Category Cat3 or better Wire Impedance 100 ohms +/ - 20% Wire Dist.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products.
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www.
デバイスPelco C1662M-Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pelco C1662M-Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPelco C1662M-Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pelco C1662M-Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pelco C1662M-Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pelco C1662M-Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPelco C1662M-Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pelco C1662M-Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPelco C1662M-Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。