PelcoメーカーC1900Mの使用説明書/サービス説明書
ページ先へ移動 of 20
Pelco • 3500 Pelco Way • Clovis , CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 International Customers: Tel (1-559) 292-1981 or FAX (1-.
2 P elco Manual C1900M (4/99) T ABLE OF CONTENTS Section Page 1.0 IMPOR T ANT SAFEGU ARDS ........................................................................................................... 3 1.1 FCC INFORMA TION ..............................
P elco Manual C1900M (4/99) 3 1.0 IMPORT ANT SAFEGUARDS 1. Read Instructions - All the safety and operating instruc- tions should be read before the unit is operated. 2. Retain Instructions - The saf ety and operating instructions should be retained for future reference.
4 P elco Manual C1900M (4/99) CA UTION RISK OF ELECTRIC SHOCK. DO NOT OPEN 1.1 FCC INFORMA TION For USA customers W ARNING - This equipment has been tested and f ound to comply with the limits f or a Class B digital device , pursuant to P ar t 15 of the FCC Rules.
P elco Manual C1900M (4/99) 5 Figure 1 . The CC3300 Series Camera 2.0 DESCRIPTION The CC3300 Series cameras are compact, rugged, full performance, general purpose color CCD cameras (see Figure 1). Contemporary styling and controls allow these cameras to blend naturally into the most modern installation sites.
6 P elco Manual C1900M (4/99) 2 4 3 5 6 7 A L 1 2 3 4 5 6 7 1 1 T op/F ront/Side Vie w of CC3300 Series Camera 2.1 LOCA TION AND FUNCTION OF PARTS 2.1.
P elco Manual C1900M (4/99) 7 8 9 10 11 12 13 14 15 16 17 B CC3300-2 CC3300-2X CC3300-3 10 11 12 13 14 15 16 8 9 8 9 17 14 Rear View of CC3300 Series Cameras 2.1.2 Rear (Illustration B ) IRIS LEVEL L/H adjustment pot This pot can be used to adjust the incident light level when using the CCD iris or a DC servo lens.
8 P elco Manual C1900M (4/99) Figure 2 . Rear P anel: CC3300-2/CC3300-2X CC3300-2/CC3300-2X See Figure 3 3.0 POWER SUPPL Y CONSIDERA TIONS Use only the recommended power supplies. Improper substitutions may damage the camera or cause a shock or fire hazard.
P elco Manual C1900M (4/99) 9 Figure 3. T ypical 120 V AC to 24 V A C (60 Hz) P ower Supply (CC3300-2 Only) NOTE: Cameras with 220-240 V AC power cords are double insulated. Article 250-45 of the National Electrical Code states that listed products protected by a system of double insu- lation shall not be required to be grounded.
10 P elco Manual C1900M (4/99) Figure 5 . Standard Acceptable Lens Dimensions 2 1 4.0 LENSES 4.1 LENS LIMITS Lenses exceeding the dimensions shown in Figure 5 below cannot be used. When the lens is not mounted on the camera head, be sure to install the dust cap to protect the internal parts from dust or damage.
P elco Manual C1900M (4/99) 11 3 4 4.3.2 Replacing the Auto Iris Lens Cable Plug (Refer to Illustration D ) Cover Auto-iris cable Rib (If the cable is thick and the plug cover does not seat properly , cut away this rib.) Lens plug 1 2 3. Apply heat to the heat shrink tubing.
12 P elco Manual C1900M (4/99) Incident Light LENS CAMERA (STYLIZED) Iris opening (sometimes referred to as aperture) is defined by f/stop numbers . The higher the number the more closed the iris is.
P elco Manual C1900M (4/99) 13 Information Box Information Box Lens/Camera Setup and Backfocusing LENS TYPE MANUAL IRIS V ARIABLE LIGHT CONDITIONS ST A TIC LIGHT CONDITIONS AUTO IRIS A B • T ur n manual iris ring so iris is fully open and set the fo- cus ring for ∞ (or distant object).
14 P elco Manual C1900M (4/99) Information Box Information Box Backfocusing MANUAL IRIS AUTO IRIS A B • Set all other switches on the back of the camer a to the left (deactivated or OFF ), includ- ing the CCD Iris switch. • This step is the same as the one for DC SER VO , except that the A UT O IRIS VIDEO/ DC s witch is set to VIDEO.
P elco Manual C1900M (4/99) 15 5.0 CAMERA INST ALLA TION A TTENTION : Installation should be per - formed by qualified service personnel only in accordance with the National Electrical Code or equivalent/applicable local codes. 5.1 CONNECTING THE CC3300-2/ CC3300-2X (Illustration F ) 1.
16 P elco Manual C1900M (4/99) F CC3300-2/ CC3300-2X 2 3 1 G CC3300-3 2 1 Connecting the CC3300-2/CC3300-2X Connecting the CC3300-3.
P elco Manual C1900M (4/99) 17 Figure 6. V er tical Phase 5.2 CONNECTING THE CC3300-3 (Illustration G ) 1. Connect the 75-ohm coaxial cable to the video monitor . 2. Connect the main leads/power cord (220-240 V AC, 50 Hz only). 5.3 VERTICAL PHASE (See Figur e 6) V ertical phase adjustment is not vertical roll adjustment.
18 P elco Manual C1900M (4/99) 7.0 MAINTENANCE • Remove dust or dirt on the surface of the lens or CCD with a blower . • Use a soft, dry cloth to clean the body . If it is very dirty , use a cloth dampened with a small quantity of a neutral detergent, then wipe dry .
P elco Manual C1900M (4/99) 19 S/N Ratio: 46 dB (AGC off) Phase Control: V-phase adjustment ( ± 90 ° ) Lens Mount: C/CS mount (adjustable) Dimensions: 5.50 in. L x 2.75 in. W x 2.56 in. H (13.97 x 6.99 x 6.51 cm) Mounting Plate Height: 0.25 inches (6.
20 P elco Manual C1900M (4/99) REVISION HISTOR Y Manual # Date Comments C1900M 11/96 Original version. 4/99 Added model CC3300-2X. P elco, the P elco logo, Camclosure, Esprit, Gene x, Legacy , and Spectra are registered trademarks of P elco. ©Copyright 1999, P elco .
デバイスPelco C1900Mの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pelco C1900Mをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPelco C1900Mの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pelco C1900Mの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pelco C1900Mで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pelco C1900Mを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPelco C1900Mの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pelco C1900Mに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPelco C1900Mデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。