PelcoメーカーC3422M-Bの使用説明書/サービス説明書
ページ先へ移動 of 20
INST ALLATION C3422M-B (3/08) Pressurized Spectra ® IV Series Pendant Back Box with Fiber Optic Option.
2 C3422M-B (3/08) Preinstallation NOTE: This manual is designed to be a reference tool for th e installatio n of your s ystem. For best results and ease of installation, the dome system should be asse mbled, pressurized, and tested before installati on.
C3422M-B (3/08) 3 3. Loosen the V -band attached to the back box and let it hang to the side. Figure 3. Loosening the V-band 4. Prepar e the lowe r dome for installation : a. Remove the O-ring fro m the lower dome. b. Lightly appl y O-ring lubr icant (supp lied) to the O- ring.
4 C3422M-B (3/08) Figure 5. Attaching the Back Box Leash 6. Install the dome drive. Refer to T able A for a list of compatible do me drives and back boxes. a. Set the DIP switch es located on the base of the dome dr ive. Refer to t he labels locat ed on the base of the dome drive or to Switch Settings on page 12 .
C3422M-B (3/08) 5 7. Install the lower dome: a. Position the lo wer dome so tha t the blower duct inside the back box is between the studs att a ched to the insid e of the lower dome. b. Install the V-band a round the lower do me and then tighten th e fastener of the V -band.
6 C3422M-B (3/08) d. Refer to the Operation/Prog ramming manu al (C 341 2M) for ins tru ctio ns on how to view the current readings for temperature and pressure.
C3422M-B (3/08) 7 Site Installation 1. Feed a fiber optic cable (not supplied) an d the supplied wiri n g harness into the front of the mount and out the back of the mount. Connect the wire s as required. Refe r to T able B, T able C, and T able D on page 10, and T able E on page 11 for cable a nd wiring infor mation.
8 C3422M-B (3/08) Figure 10. Removing the Back Box Mounting Plate 3. Thread the wiring fro m the mount throug h the mounting plat e, and then attach the mounting plate to the mount. If outdoors, apply threa d compound (sup plied) to the t hreads on the mounting p late.
C3422M-B (3/08) 9 Figure 12. Attaching the Wire Harness Connector.
10 C3422M-B (3/08) . NOTES: • Input power f or the dome is 24 V AC only . Power consumpt ion is 73 V A per dome. • Use a 24 V AC transformer with a minimum of 100 V A.
C3422M-B (3/08) 11 T able E. Configuration of Wire Harness Pin Wire Color Function 9-Conductor Cable AB l a c k A l a r m 1 BR e d A l a r m 2 C White Alarm 3 DG r e e n A l a r m 4 EB r o w n A l a r m 5 F Orange Alarm 6 G Y ellow Alarm 7 H Violet Ground – Blue N ot Used 5-Conductor Cable J Black Relay N.
12 C3422M-B (3/08) Switch Settings WAR N IN G : If you are using Pelco D or Pelco P pr otocol control, your system may not oper ate if the baud rate and address swi tches are not set correc tly . The switches are set at the facto ry at the def aults for Pelco D protoc ol control (2400 bau d and address 1).
C3422M-B (3/08) 13 T able G. Switch Settings for SW1, Pelco P Protocol Control NOTE: For Coaxitron con trols, SW1 is no t used; set all switches t o the OFF pos ition.
14 C3422M-B (3/08) SPECTRA ADDRESS SWITCH SETTI NG SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 71 ON ON ON OFF OFF OFF ON OFF 72 OFF OFF OFF ON OFF OFF ON OFF 73 ON OFF OFF ON OFF OFF ON OFF 74 OF.
C3422M-B (3/08) 15 SPECTRA ADDRESS SWITCH SETTI NG SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 151 ON ON ON OFF ON OFF OFF ON 152 OFF OFF OFF ON ON OFF OFF ON 153 ON OFF OFF ON ON OFF OFF ON 154 O.
16 C3422M-B (3/08) SPECTRA ADDRESS SWITCH SETTI NG SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 223 ON ON ON ON ON OFF ON ON 224 OFF OFF OFF OFF OFF ON ON ON 225 ON OFF OFF OFF OFF ON ON ON 226 OFF.
C3422M-B (3/08) 17 Specifications GENERAL Construction Back Box 316L stainless steel Dome Drive Aluminum, thermoplastic Lower Dome T rim Rin g 316L stainle ss steel Bubble Polycarbonate, 0 .09-inch thick V-Band 316L stainle ss steel Pressure Rel ief Brass Schrader V alve Brass Connector Nickel-plated steel Light Attenuat ion Smoked f/1.
18 C3422M-B (3/08) Input Power 24 V A C 73 VA nominal (with heater) 24 VDC 3 A nominal (with heater) Fuse 1.25 A Auxiliary Outputs 2 Alarm Inputs 7 5.9 (15.1) 11.6 (29.5) 10.6 (26.7) NOTE: VALUES IN PARENT HESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.
PRODUCT W ARRANTY AND RETURN INFORMA TION WARRANTY Pelco will r epair or repla c e, without charge, any merchandise p roved defectiv e in material or wor kmanship for a period of one year after the date o f shipment.
W orldwid e Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
デバイスPelco C3422M-Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pelco C3422M-Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPelco C3422M-Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pelco C3422M-Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pelco C3422M-Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pelco C3422M-Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPelco C3422M-Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pelco C3422M-Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPelco C3422M-Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。