CM6700 Matrix Switcher/Contr oller Installation/ Operation Manual C523M-H (6/05) ® Pelco • 3500 Pelco W ay • Clovis, CA 93612-5699 USA • www .pelco.
2 Pelco Manual C523M-H (6/05) CONTENTS Section Page IMPORT ANT SAFEGUARDS AND WARNINGS ................................................................ 3 MODELS ..........................................................................................
Pelco Manual C523M-H (6/05) 3 IMPOR T ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes.
4 Pelco Manual C523M-H (6/05) MODELS CM6700-MXB2 Matrix switcher/controller with 16 video inputs and 2 monitor outputs, 120 V AC, 50/60 Hz CM6700-MXB2-X Same as CM6700-MXB2, P AL-configured for 230 V .
Pelco Manual C523M-H (6/05) 5 DESCRIPTION Pelco’s CM6700 is a keyboard-controlled cross-point video matrix switcher/control unit (SCU) that allows you to route up to sixteen video images to as many as four monitors while controlling camera positions.
6 Pelco Manual C523M-H (6/05) Figure 1. CM6700 Applications VIDEO INPUTS 1 3 5 7 9 1 13 15 2 4 6 8 10 12 14 16 VIDEO OUTPUTS 1 2 3 4 LOCAL KEYBOARD REMO TE KEYBOARDS LOCAL KEYBOARD RS-422 (P OR D) RS-.
Pelco Manual C523M-H (6/05) 7 Figure 2. Application with a Multiplexer Figure 3. Applications with Remote Keyboards (ASCII, KBD200A Only) VIDEO INPUTS 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 VIDEO OUTP.
8 Pelco Manual C523M-H (6/05) INST ALLA TION 1 SET OPTIONS 1. Refer to Figure 4. Remove the cover . Figure 4. Cover Removal 2. Refer to Figure 5. Set jumpers according to your system requirements. JP1-JP16 are used to terminate the video input with a 75-ohm resistor or to unterminate the video (looping).
Pelco Manual C523M-H (6/05) 9 3. Refer to Figure 6. Set DIP switches. a. Communication port 2 is available for a PC or remote keyboard operating in ASCII mode. (Refer to ASCII Operating Commands .) Most PC applications require RS-232. A remote keyboard can require either RS-232 or RS-422, depending on the communications facility .
10 Pelco Manual C523M-H (6/05) 3. Refer to Figure 8. Use suitable hardware to mount the SCU an in equipment bay or against a flat surface, according to your installation requirements. Figure 8. Mounting the Matrix Switcher MOUNT T O RACK OR SURFACE WITH 4 SCREWS 3 CONNECT VIDEO SOURCES Refer to Figure 9.
Pelco Manual C523M-H (6/05) 11 4 CONNECT CONTROL LINES 1. Connect camera control lines to receivers. If your video sources are all controlled by Coaxitron, skip this section and go to step 5 .
12 Pelco Manual C523M-H (6/05) b. A star configuration (going to each receiver from a central connecting point) is sometimes more practical. Y our installation will be easier to maintain and trouble- .
Pelco Manual C523M-H (6/05) 13 5 CONNECT MONITORS 1. Y our SCU will support either two or four monitors. Models CM6700-MXB4 and CM6700-MXB4-X support four monitors (Monitors 1-4). Models CM6700-MXB2 and CM6700-MXB2-X support two monitors (Monitor 1 and 2).
14 Pelco Manual C523M-H (6/05) 6 CONNECT ALARMS 1. Refer to Figure 14. Alarm inputs 1-16 correspond to video inputs 1-16. If an open door sensor is connected to alarm input 1, when the sensor is activated the video image from camera 1 will be displayed on one of the four monitors and the camera will move to a preset (determined by programming).
Pelco Manual C523M-H (6/05) 15 7 CONNECT AUXILIARIES The SCU provides three auxiliary (AUX) outputs for controlling VCRs and other devices. These outputs can be activated directly from a keyboard by using the F1, F2, and F3 func- tion keys, or they can be activated by an alarm (determined by programming).
16 Pelco Manual C523M-H (6/05) Figure 16. Wiring the AUX 2 and AUX 3 (TTL) Outputs VIDEO INPUTS 1 3 5 7 9 1 13 15 2 4 6 8 10 12 14 16 VIDEO OUTPUTS 1 2 3 4 LOCAL KEYBOARD 12-PIN PLUG-IN CONNECTOR CONTROL OUTPUTS NOT USED 12-PIN TERMINAL STRIP ON REAR OF SCU R INPUT FROM VIDEO OUTPUT LOOPED TO MONITOR DEVICE, EX.
Pelco Manual C523M-H (6/05) 17 8 CONNECT COM 2 PORT Y ou will need to use the COM 2 port if your system includes an ASCII control device, such as a personal computer or a keyboard that is connected via dial-up lines or fiber optic net- work. The port interface at COM 2 can be either RS-232 or RS-422/485.
18 Pelco Manual C523M-H (6/05) 9 CONNECT KEYBOARDS Pelco offers three keyboard models for use with the CM6700 matrix switcher . Complete in- stallation instructions are provided with each keyboard. The most common connections are for local and remote keyboards.
Pelco Manual C523M-H (6/05) 19 8. Plug in all keyboard data cables. 9. Plug the KBDKIT or KBDKIT -X transformers into a suitable outlet and apply power to the SCU. 10. T o initialize a keyboard, wait five seconds after power-up, enter the number for the monitor you are viewing (1-4) and press MON.
20 Pelco Manual C523M-H (6/05) PROGRAMMING Programming allows you to assign titles for cameras, establish monitor group sequences, enable/disable alarms, establish access restrictions, set alarm options, set time and date, change password, and set auxiliary options.
Figure 21. Quick Reference Chart Pelco Manual C523M-H (6/05) 21 PGM PG ACK ACK PRESS Enter Camera #. Enter Camera Title (1-20 characters). Select Receiver Type (Std. Coaxitron, Ext. Coaxitron, 422D, or 422P). Keypad F1/F2 F1/F2 or Pan L/R Keypad Keypad F1/F2 F1/F2 or Pan L/R Pan right Enter Monitor # (1-4).
22 Pelco Manual C523M-H (6/05) PROCEDURE METHOD Enter Old Password. Enter New Password. Enter New Password again. Keypad Keypad Keypad RETURN SET PASSWORD OLD PASSWORD ******* NEW PASSWORD ******* VERIFICATION ******* T able B. Programming the CM6700 Switching Control Unit (Continued) Step 2 Function Action Result Change a.
Pelco Manual C523M-H (6/05) 23 T able B. Programming the CM6700 Switching Control Unit (Continued) Step 3 Function Action Result a. Enter the Main Menu. b. Press 1. c. Enter the desired camera number (01-16) or pan left/right to show the desired camera number .
24 Pelco Manual C523M-H (6/05) T able B. Programming the CM6700 Switching Control Unit (Continued) Step 4 Function Action Result a. Enter the Main Menu. b. Press 2. c. Enter the desired monitor number (01-04) or pan left/ right to show the desired monitor number .
Pelco Manual C523M-H (6/05) 25 T able B. Programming the CM6700 Switching Control Unit (Continued) Step 4 ( Continued ) Function Action Result o. Move down to the 2. ALARM ENABLE field. p. Pan right. q. T urn each alarm on or off. r. Move down to RETURN.
26 Pelco Manual C523M-H (6/05) T able B. Programming the CM6700 Switching Control Unit (Continued) Step 5 Function Action Result a. Enter the Main Menu. b. Press 3. T ake note of the contents of the STYLE and TYPE fields for the following procedure. The Style must be MMM-DD-YY and the T ype must be 12 hour .
Pelco Manual C523M-H (6/05) 27 T able B. Programming the CM6700 Switching Control Unit (Continued) Step 5 (Continued) Function Action Result r. Use F1 and F2 to select the desired style (DD-MM-YY , MM-DD-YY , DD-MMM-YY and MMM-DD-YY). s. Move down to the TYPE field.
28 Pelco Manual C523M-H (6/05) T able B. Programming the CM6700 Switching Control Unit (Continued) Step 6 Function Action Result Program a. Enter the Main Menu. Alarms 1-16 b. Press 4. c. Pan right. d. Move down to the ALM ENABLE 1 field. e. Use the F1 and F2 keys to toggle the Alarm Enable field (* = ON, -- = OFF).
Pelco Manual C523M-H (6/05) 29 T able B. Programming the CM6700 Switching Control Unit (Continued) Step 6 (Continued) Function Action Result o. Pan right. p. Move down to the ALM ENABLE 9 field. q. Repeat steps e through l for alarms 9 through 16. Then go to step r .
30 Pelco Manual C523M-H (6/05) T able B. Programming the CM6700 Switching Control Unit (Continued) Step 7 Function Action Result Program a. Enter the Main Menu. Alarms 17 & 18 b. Press 4. c. Press 2. d. Move down to the ENABLE field. e. Use the F1 and F2 keys to toggle the Alarm Enable field (* = ON, -- = OFF).
Pelco Manual C523M-H (6/05) 31 T able B. Programming the CM6700 Switching Control Unit (Continued) Step 7 (Continued) Function Action Result n. Use the sequence and macro keys (KBD100) or pan and tilt to move through the matrix and use the keypad to assign the presets for each MON/CAM entry .
32 Pelco Manual C523M-H (6/05) T able B. Programming the CM6700 Switching Control Unit (Continued) Step 8 Function Action Result Program a. Enter the Main Menu. Com Ports b. Press 5. c. T o configure port 1, go to step d. To skip port 1 and configure port 2, go to step j.
Pelco Manual C523M-H (6/05) 33 T able B. Programming the CM6700 Switching Control Unit (Continued) Step 9 Function Action Result a. Enter the Main Menu. b. Press 6. c. Use the F1 and F2 keys to select the source. d. Pan right. e. Use F1 and F2 to select the mode.
34 Pelco Manual C523M-H (6/05) T able B. Programming the CM6700 Switching Control Unit (Continued) Step 10 Function Action Result a. Enter the Main Menu. b. Press 8. c. Pan right. d. Use the F1 and F2 keys to toggle the keyboard 1/ monitor 1 access entry .
Pelco Manual C523M-H (6/05) 35 T able B. Programming the CM6700 Switching Control Unit (Continued) Step 11 Function Action Result Program a. Enter the Main Menu. Camera Access b. Press 8. Access determines which camera images are shown on which monitors.
36 Pelco Manual C523M-H (6/05) OPERA TION The CM6700 can be operated with a KBD100, KBD200A, or KBD300A keyboard. It ca n also be operated from a PC with ASCII operating commands.
Pelco Manual C523M-H (6/05) 37 T able D. ASCII Commands Number ranges are enclosed in brackets–do not enter the brackets. When you control a fixed speed pan and tilt, omit the speed information. Desired Action Command Result Select monitor [1-9999]Ma Calls a monitor to use for camera operation.
38 Pelco Manual C523M-H (6/05) T able D. ASCII Commands (Continued) Desired Action Command Result Start macro [1-99]Sa Acknowledge alarm [1-9999]Ia Send camera titles Y a[string1/…/string16]!a Send .
Pelco Manual C523M-H (6/05) 39 TROUBLESHOOTING GAINING INITIAL CONTROL If you are having problems gaining control of your system for the first time: 1. Confirm that everything is plugged in and has power . 2. Confirm that multiple keyboards have different DIP switch addresses.
40 Pelco Manual C523M-H (6/05) T able E. Solutions T o Common Problems Problem Remedy CM6700 does not have power . Make sure the power cord is plugged in. Check the fuse. Refer to Figure 6 for the fuse location. Y ou can see some cameras and not others Confirm that the camera is properly connected and has power .
Pelco Manual C523M-H (6/05) 41 SPECIFICA TIONS SWITCHING Programmable Switching Duration: User-defined between 1 and 99 seconds Programmable Number of Steps per Sequence: 16 Maximum Number of Sequence.
42 Pelco Manual C523M-H (6/05) AUXILIAR Y OUTPUTS Number of Outputs: 3 Connector T ype: 12-pin screw terminal Contact Configuration F1: Form C, 0.5 A at 125 V AC maximum F2 and F3: Open collector , 32.
Pelco Manual C523M-H (6/05) 43 INDEX A Alarm dwell 24 Alarm enable 28 Alarm inputs 5, 14 Alarm type 24 ASCII 5, 9, 17, 36 ASCII operating commands 36 Assign camera titles 23 AUX F1 15, 33 AUX F2 15, 3.
REVISION HISTOR Y Manual # Date Comments C523M 6/97 Original version. C523M-A 10/97 Revised to add KBD300 keyboard information, update drawings, and expand troubleshooting section. C523M-B 4/98 Revised keyboard installation instructions as a result of hardware changes to rear panel.
デバイスPelco CM6700の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pelco CM6700をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPelco CM6700の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pelco CM6700の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pelco CM6700で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pelco CM6700を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPelco CM6700の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pelco CM6700に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPelco CM6700デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。