Pelcoメーカーes30-isapの使用説明書/サービス説明書
ページ先へ移動 of 32
ES30-ISAP Pan and T ilt System C312M-A (12/02) ® OPERA TION/PROGRAMMING.
2 C312M-A (12/02) CONTENTS Section Page DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C312M-A (12/02) 3 LIST OF ILLUSTRA TIONS Figure Page 1 POD 100 Attachment to the T ilt T able . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 C312M-A (12/02) DESCRIPTION The ES30-ISAP is an innovative addition to the Esprit ® Series Positioning System family designed specifically for the POD 100 Thermal Imager (not supplied). The system includes the Esprit receiver , pan and tilt, power supply , and an exclusively designed connector and mount for the thermal imager .
C312M-A (12/02) 5 INST ALLA TION POD 100 1. Refer to Figure 1 and attach the POD 100 to the tilt table of the Esprit with the 1/4-20 x .50-inch screw (supplied). POD100 TIL T T ABLE ESPRIT P AN AND TIL T SYSTEM Figure 1. POD 100 Attachment to the Tilt Table 2.
6 C312M-A (12/02) P AN AND TIL T 1. Remove the transformer module from the base of the system by loosening the four Phillips screws and lifting the module.
C312M-A (12/02) 7 3. Route the wires and cables from the transformer module through the center of the Esprit mount. Reinstall the transformer module into the base. The transformer module can be positioned in the mount base in only one orientation. 120/230 VOL T AGE SELECTOR SWITCH 4.
8 C312M-A (12/02) 8. Plug the male Esprit system connector , located on the bottom of the pan and tilt, into the female Esprit system connector loc ated on the transformer module. Align the pan and tilt part number with the alignment label on the base, and then attach the pan and tilt to the base with three 1/4-20 nuts and washers (supplied).
C312M-A (12/02) 9 TXB SERIES TRANSLA TOR BOARD INST ALLA TION (OPTIONAL) Pelco’ s TXB Series allows controllers from other companies to communicate with the Esprit system.
10 C312M-A (12/02) To reinstall the pan and tilt cover , do the following: 1. Properly position the cover and slide it into place. The sides of the cover must fit under the front and back rain guards of the pan and tilt, and the top of the cover must seat against the lip of the top gasket.
C312M-A (12/02) 11 OPERA TION POWER-UP DISPLA Y When the Esprit system is powered up or reset, the selected protocol, revision number , and other information is displayed on th e monitor . The information remains on the monitor until the system is moved.
12 C312M-A (12/02) OPERA TING NOTES ENVIRONMENT AL RANGE The operating temperature ranges from a minimum of -40 ° F (-40 ° C) to a maximum of 122 ° F (50 ° C) for sustained system operation or 140 ° F (60 ° C) absolute maximum.
C312M-A (12/02) 13 RANDOM, FRAME, AND AUTO SCANNING Select preset 97 (30) to start random scanning. Select preset 98 (31) to activate frame scanning (three seconds of scanning followed by a three-second pause). Select preset 99 (32) to start auto (continuous) scanning.
14 C312M-A (12/02) QUICK ST ART GUIDE – SYSTEM SETUP PROGRAMMING GUIDE – ES30-ISAP P AN AND AND TIL T SYSTEM 1. Access main menu (preset 95). 2. Make main menu selections. Joystick: Move up or down to position cursor or to toggle between selections.
C312M-A (12/02) 15 HOW TO ACCESS THE MAIN MENU (PRESET 95) Y ou can call up the main menu on your monitor by programming (setting or creating) preset 95 (preset 28 if in AD32-preset mode). Programming preset 95 for Pelco’ s controllers varies according to the type of controller you are using.
16 C312M-A (12/02) CAMERA For information on camera operation, refer to the manual supplied with the POD 100 thermal imager or contact Industrial Security Alliance Partners, Inc.
C312M-A (12/02) 17 LIMIT STOPS TURNING LIMIT STOPS ON OR OFF To change the limit stop mode: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Limit Stop. 3. Press the Iris Open button to enter the Limit Stop menu. 4.
18 C312M-A (12/02) Clear Manual Stops To clear the manual limit stops: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Limit Stop. 3. Press the Iris Open button to enter the Limit Stop menu. 4. Move the cursor to Clear Man Limits, and press the Iris Open button.
C312M-A (12/02) 19 LINE SYNCHRONIZA TION If cameras are out of phase with each other , they may produce what appears to be vertical roll when switching between cameras. There are two settings for line synchronization: ON – Adjust the synchronization of the power line voltage so that it is in phase with other cameras.
20 C312M-A (12/02) PA TTERN LENGTH The ESPRIT can do the following: One full pattern – 1.5, 3, or 6 minutes long or T wo half patterns – .75, 1.5, or 3 minutes long This pattern can consist of any standard pan and tilt command. Presets, flip, and turbo are not allowed in a pattern.
C312M-A (12/02) 21 POWER-UP MODE This feature lets the system resume a desired condition following power -up. The menu includes the following choices. • Default – On power -up, the system goes through a configuration cycle and stops at zero reference, showing “Configuration Done,” address, and mode settings on the screen.
22 C312M-A (12/02) PROPORTIONAL P AN Proportional pan does not function with this version of Esprit. Main Menu <Camera> <Line Sync> <Power Up Mode> <Limit Stop> <Other> EXIT Other Menu Proportional pan On Park time minutes 0 Scan speed deg/s 25 Pattern length 1.
C312M-A (12/02) 23 SCAN SPEED The scan speed is adjustable from 1-40 degrees per second. This occurs in three scan modes: auto, random, and frame scan. To change the scan speed: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Other .
24 C312M-A (12/02) ZONES Basic rules for setting zones: 1. Refer to the documentation for your control system to program zones. 2. Establish zones using the controller , prior to programming ZONE BLANK with the Esprit on-screen menu. 3. T o accurately set zone areas, zoom wide to the maximum field of view .
C312M-A (12/02) 25 PRODUCT SUPPORT ES30-ISAP PAN AND TIL T SYSTEM CONT ACT : Pelco 3500 Pelco Way Clovis, CA 93612 USA T el: 800/289-9100 (USA & Canada) 1-559/292-1981 (International) www .pelco.com POD 100 THERMAL IMAGER (CAMERA) CONT ACT : Industrial Security Alliance Partners, Inc.
26 C312M-A (12/02) APPENDIX NOTE: Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mode.
C312M-A (12/02) 27 Table B. Switch Settings for SW2 Receiver Address Switch Setting P-T ype D-T ype Control Control SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 1– OFF OFF OFF OFF OFF OFF OFF OFF.
28 C312M-A (12/02) Table B. Switch Settings for SW2 (Continued) (Continued on next page) Receiver Address Switch Setting P-T ype D-T ype Control Control SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8.
C312M-A (12/02) 29 Table B. Switch Settings for SW2 (Continued) Receiver Address Switch Setting P-T ype D-T ype Control Control SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 – 232 OFF OFF OFF ON O.
30 C312M-A (12/02) SPECIFICA TIONS (PAN AND TIL T SYSTEM ONL Y) ELECTRICAL Input V oltage: 24, 120, or 230 V AC, 50/60 Hz; switch selectable for 120/230 V AC inputs Output V oltage for POD100: 12 VDC .
C312M-A (12/02) 31 ® Pelco, the Pelco logo, Spectra, Genex, Legacy, Coaxitron, Esprit, and Camclosure are register ed trademarks of Pelco. © Copyright 2002, Pelco. All rights reserved. REVISION HISTORY Manual # Date Comments C312M 11/02 Original version.
World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.
デバイスPelco es30-isapの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pelco es30-isapをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPelco es30-isapの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pelco es30-isapの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pelco es30-isapで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pelco es30-isapを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPelco es30-isapの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pelco es30-isapに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPelco es30-isapデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。