PelcoメーカーICS210の使用説明書/サービス説明書
ページ先へ移動 of 20
INST ALLA TION ICS210 Series Camclosure ® Integrated Camera System C2491M-D (8/06).
2 C2491M-D (8/06) Contents Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C2491M-D (8/06) 3 Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
4 C2491M-D (8/06) Description The ICS210 Series Camclosure ® is a wedge style integrated camera system that is quick and easy to install. The system is designed to mount directly to a wall or ceiling, or to a corner with the ICS210- CM corner mount. ICS210 system is shipped fully assembled.
C2491M-D (8/06) 5 Installation PREPARE MOUNTING SURFACE 1. Remove the cover of the ICS210. Use the screwdriver bit that is provided to loosen the three tamperproof screws, and then lift the cover from the base. 2. Remove the camera assembly from the base by removing the Phillips screws on each side of the camera assembly (refer to Figure 2 ).
6 C2491M-D (8/06) 4. Select a fi xed or adjustable mounting pattern (refer to Figure 3 and Figure 4 ). Using the mounting plate as a template, mark the wire feedthrough and fastener hole positions on the mounting surface. Prepare the holes for the installation.
C2491M-D (8/06) 7 INSTALL BASE WITHOUT CONDUIT 1. Pull the power and video wiring for the camera through the mounting surface and then through the wiring hole in the mounting plate. Fasten the mounting plate to the mounting surface with #8 stainless steel screws (not provided) of the appropriate length.
8 C2491M-D (8/06) 3. Using a blunt tool push out the wiring plug in the bottom of the base (refer to Figure 6). Pull the wiring inside the base. Figure 6. Removing the Wiring Plug 4. Insert the hole plug that is supplied into the hole in the base of the Camclosure (refer to Figure 7).
C2491M-D (8/06) 9 5. Pull wiring through the conduit opening (refer to Figure 8): a. Use a 1/16” hex head wrench to loosen the hex head inset screw . b. Use a screwdriver to remove the conduit cover. c. Pull the power wires and video cable through the conduit opening.
10 C2491M-D (8/06) REINSTALL CAMERA MODULE Reinstall the camera module. Refer to Figure 9 . Make sure the top of the camera is oriented properly . On the lens housing, look for the label that says TOP . Figure 9. Camera Installation ADJUST POSITION 1.
C2491M-D (8/06) 11 REPLACE COVER Place the cover of the ICS210 onto the base of the unit. Using the screwdriver bit (supplied), tighten the three tamperproof screws.
12 C2491M-D (8/06) Adjustments (Color Camera Only) If you have a color camera, it is set up at the factory and normally requires no adjustments. Sometimes, however , adjustments may be necessary. 1. Remove the cover using the supplied 1/8-inch hollow screwdriver bit.
C2491M-D (8/06) 13 AUTO IRIS LEVEL ADJUSTMENT If you have a varifocal lens or fi xed focal length lens with an auto iris, you can adjust the iris level setting to increase or decrease brightness. Figure 12. Iris Level Adjustment FOCUS ADJUSTMENT FOR FIXED FOCAL LENGTH LENS WITH AUTO IRIS T o adjust the focus, do the following: 1.
14 C2491M-D (8/06) HEATER BOARD REMOVAL T o remove the heater board, do the following: 1. Disconnect the four -pin heater connector (red, orange, and black wires) if it is plugged in. Figure 14. Removing Heater Board 2. Wait for the heater elements to cool if they are hot.
C2491M-D (8/06) 15 SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITH AUTO IRIS Refer to Figure 15 . The switch is located next to the lens. Automatic backlight compensation (factory setting) is used under varying lighting conditions (such as outdoors) or fi xed lighting conditions where there are no bright spots that darken other picture details.
16 C2491M-D (8/06) SWITCH SETTINGS FOR V ARIFOCAL LENS The high resolution camera with varifocal lens and auto iris is confi gured at the factory for automatic exposure. Figure 17. Switch Settings for Varifocal Lens For manually setting and locking the white balance Place a white background in front of camera and turn off switch 1.
C2491M-D (8/06) 17 Specifications General Pan/T ilt Adjustment Manual; 5° above horizontal to 20° below horizontal tilt; 24° pan adjustment when using the adjustable mounting pattern in base Ratin.
18 C2491M-D (8/06) REVISION HISTORY Manual # Date Comments C2491M 6/05 Orginal version. C2491M-A 7/05 Revised per new camera shell design for varifocal lens. C2491M-B 10/05 Revised switch-setting descriptions for varifocal lens. C2491M-C 1/06 Revised factory switch settings for varifocal lens.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products.
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www.
デバイスPelco ICS210の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pelco ICS210をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPelco ICS210の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pelco ICS210の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pelco ICS210で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pelco ICS210を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPelco ICS210の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pelco ICS210に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPelco ICS210デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。