REL2064 Relay Interface Unit C1518M-A (11/02) ® INST ALLA TION/OPERA TION.
2 C1518M-A (11/02) CONTENTS Section Page IMPORT ANT SAFEGUARDS AND W ARNINGS .............................................................................................. .................................................................... 3 OVERVIEW .
C1518M-A (11/02) 3 IMPORT ANT SAFEGUARDS AND W ARNINGS 1. Read, keep, and follow these instructions. 2. Heed all warnings. 3. There are no user -serviceable parts inside this unit. Only authorized service personnel may open the unit. 4. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
4 C1518M-A (11/02) Figure 1. Front View with Panel Removal OVERVIEW DESCRIPTION The REL2064 Relay Interface Unit provides up to 64 single-pole, single-throw (SPST) dry contact outputs for direct or automatic control of peripheral equipment.
C1518M-A (11/02) 5 REAR VIEW The rear of the REL2064 unit consists of the following: 1. Four groups of 16 contact pairs, each with mating plugs for the attachment of peripheral equipment; only the group for the first 16 contact pairs is shown in Figure 2 with mating plugs 2.
6 C1518M-A (11/02) Figure 3. Rack-Mount Installation WIRING RELA YS The relay unit has four groups of relay contacts. Each group represents 16 pairs of relay contacts: • Group I – 1-8, 9-16 • Gr.
C1518M-A (11/02) 7 Figure 4. Relay Interface Contact Configuration 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 00702.
8 C1518M-A (11/02) Figure 5. Wiring Relays to Peripheral Equipment 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 32-122F (0-50C) + — 9 WA RNING: W ARNING: 00703.
C1518M-A (11/02) 9 CONNECTING TO THE CM6800 Connect the supplied RJ-45 straight cable from the REL2064 OUT port to the CM6800 COM 3 port. The active pin-outs are associated with the four outer pins: 1, 2, 7, and 8.
10 C1518M-A (11/02) SETTING THE DIP SWITCHES The positioning of the DIP switches on the front of the relay unit deter mines how the relay unit operates. Y ou must recycle pow er whenever you make changes to the DIP switches. 1. Remove the front panel by unscrewing the five flat-head Phillips screws.
C1518M-A (11/02) 11 2. Set the DIP switches. Figure 7. SW1 DIP Switches DIAGNOSTICS: OFF LOCAL DEVICE ADDRESS ON 1 2 3 4 5 6 7 8 9 10 NOT USED: OFF DEF AUL T SETTINGS: LOCAL DEVICE ADDRESS 1, DIP SWIT.
12 C1518M-A (11/02) OPERA TION The function of the relay unit is to operate relays to control peripheral equipment. Each relay unit processes and executes only commands with addresses that match those of the relay units. When power is turned on, the green power LEDs on the front and back of the unit light.
C1518M-A (11/02) 13 OPERA TING RELA YS FROM THE KBD960 To operate relays from a KBD960 keyboard, you must know which GPI to call, and which auxiliary (AUX) to select on the keyboard. Y ou can cascade two relay units. Each relay unit has eight GPIs. Relay Unit 1 has a GPI range of 1-8, and Relay Unit 2 has a GPI range of 9-16.
14 C1518M-A (11/02) Table D. Relay Unit 1 GPI Relay Contacts 1 12345678 29 1 0 11 12 13 14 15 16 31 7 1 81 92 02 12 22 32 4 42 5 2 62 72 82 93 03 13 2 53 3 3 43 53 63 73 83 94 0 64 1 4 24 34 44 54 64 74 8 74 9 5 05 15 25 35 45 55 6 85 7 5 85 96 06 16 26 36 4 Associated Aux 12345678 Table E.
C1518M-A (11/02) 15 Figure 10. Power Input Fuse Replacement Problem Why were the contact positions lost when there was a power failure? Why is the unit not operating as it should? What is the DB9 port used for? Solution Make sure DIP switches 3-6 of SW3 are enabled so that your settings remain in memory .
16 C1518M-A (11/02) DIP Switch Address 12345678 1 00000000 2 10000000 3 01000000 4 11000000 5 00100000 6 10100000 7 01100000 8 11100000 9 00010000 10 10010000 11 01010000 12 11010000 13 00110000 14 10.
C1518M-A (11/02) 17 DIP Switch Address 12345678 125 00111110 126 10111110 127 01111110 128 11111110 129 00000001 130 10000001 131 01000001 132 11000001 133 00100001 134 10100001 135 01100001 136 11100.
18 C1518M-A (11/02) Figure 11. REL2064 Dimension Diagram 19.00 (48.26) PWR ALARM REL2064 Relay Interface Unit Made in USA 17.40 (44.20) 1.75 (4.45) 8.15 (20.
C1518M-A (11/02) 19 REVISION HISTORY Manual # Date Comments C1518M 5/01 Original version. C1518M-A 11/02 Updated manual to new format. Revised T able A and updated T able B. ® Pelco, the Pelco logo, Spectra, Genex, Esprit, Camclosure, and Legacy are registered trademarks of Pelco.
World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.
デバイスPelco REL2064の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pelco REL2064をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPelco REL2064の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pelco REL2064の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pelco REL2064で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pelco REL2064を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPelco REL2064の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pelco REL2064に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPelco REL2064デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。