Pentairメーカー4HP-VD - 3' STDの使用説明書/サービス説明書
ページ先へ移動 of 12
P/N 350039 Rev. C 8-24-06 1 OptiFlo ® Plastic Pump for Aboveground Pools Installation, Operation & Service Manual Pentair Water Pool and Spa, Inc. 1620 Hawkins Ave., Sanford, NC 27330 • 800-831-7133 or (919) 566-8000 10951 West Los Angeles Ave.
P/N 350039 Rev. C 8-24-06 2 OptiFlo ® Engineered Plastic Pump Installation, Operation & Service Manual T able of Contents SECTION I. HOW YOUR PUMP WORKS .............................................................................................
P/N 350039 Rev. C 8-24-06 3 W ARNING To reduce the risk of electrical shock, do not use an extension cord to connect unit to electric supply; provide a properly located outlet. W ARNING For continued protection against possible electrical shock, this unit is to be mounted to the base in accordance with the installation instructions.
P/N 350039 Rev. C 8-24-06 4 4. Provide space and lighting for routine maintenance access. Do not mount electrical controls directly over pump. 5. The pump should be installed as near to the pool or spa as practical. Avoid installing the pump above the water level .
P/N 350039 Rev. C 8-24-06 5 17 . The pump motor must be wired for the proper voltage in accordance with the wiring diagram supplied with the motor. Wiring the motor with the incorrect supply voltage will cause damage to the motor and void the warranty.
P/N 350039 Rev. C 8-24-06 6 INITIAL START-UP: 1. Relieve all system pressure and open all air bleeders on total hydraulic system prior to starting the pump. See filter owner's manual. 2. Ensure that all fittings, clamps, closures and couplings are tight and in accordance with equipment manufacturer's recommendations.
P/N 350039 Rev. C 8-24-06 7 4. Use extreme care when handling the mechanical seal. The mating seal surfaces are polished and are easily damaged. 5. The mechanical seal can be changed without disconnec.
P/N 350039 Rev. C 8-24-06 8 SECTION VI. TROUBLESHOOTING GUIDE The following are some common causes of problems that may arise. PROBLEM CAUSE REMEDY Pump will not prime. No water in strainer pot. Add water to pot. Strainer pot lid is not tight. T ighten lid.
P/N 350039 Rev. C 8-24-06 9 SECTION VII. TECHNICAL DATA REPLACEMENT PARTS 9 7 11 8 4 1 14 5 12 10 15 2 6 3 13 Item No. Part No. D escription 1 357161 D r a i n P l u g, 3 r eq . 2 354545 Mechanical Seal 3 354552 I mpeller 3/4 hp 3 350017 Impeller 1 hp 3 350018 I m peller 1-1/2 hp 4 1921 15 O -ring, 3 req.
P/N 350039 Rev. C 8-24-06 10 10 9 8 7 6 5 4 3 2 1 REPLACEMENT PARTS (BASE MOUNTED UNITS) For cord and plug connected units, the base should be mounted as shown. Suction V ertical Discharge 7.75" 4.09" 3.50" 7.26" 10.00" 9.33" Item No.
P/N 350039 Rev. C 8-24-06 11 PUMP CURVES Pentair Pool Products ® OptiFlo ® Series 50 Hz Pump Curves 0 5 10 15 20 25 30 35 01 0 20 30 40 50 60 70 80 Flow Rate in US GPM Total Dynamic Head in Ft. of Water METERS OF WA TER CUBIC METERS PER HOUR 3/4 HP 3/4 HP 1 HP 1 HP 1.
P/N 350039 Rev. C 8-24-06 12 ENGINEERING SPECIFICATIONS .
デバイスPentair 4HP-VD - 3' STDの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pentair 4HP-VD - 3' STDをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPentair 4HP-VD - 3' STDの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pentair 4HP-VD - 3' STDの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pentair 4HP-VD - 3' STDで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pentair 4HP-VD - 3' STDを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPentair 4HP-VD - 3' STDの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pentair 4HP-VD - 3' STDに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPentair 4HP-VD - 3' STDデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。