Model 5600 & 5600 Econominder ® Service Manual IMPORTA NT: Fill in p ertinent info rmation on page 3 for future reference..
2 Model 5600 & 5600 Econominder ® Table of Contents Job Specification Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 General Residential Installation Check List .
Model 5600 & 5600 Econominder ® 3 Job Specification Sheet Job Number _______________ _________________ ___ Model Number __ __________________ ____________ W ater T est _____________ _________________ ______ Capacity of Unit __________ ______________ Max.
4 Model 5600 & 5600 Econominder ® General Residential Installation Check List W at er Pressur e A minimum of 25 lbs of water pressure is r equ ired for regeneration valve to operate effectively . Electrical Facilities An uninterrupted alternating current (A/C) suppl y is required.
Model 5600 & 5600 Econominder ® 5 Valve Installation and Start-up Procedures 1. Place the softener ta nk where you want to install the unit. NOTE: Be sure the tank is level and on a firm base. 2. During cold weather it is recommended th at the installer warm the valve to room temperature before operatin g.
6 Model 5600 & 5600 Econominder ® Model 5600 Installation and Start-up Procedures NOTE: Install the water softener with th e inlet, outlet and drain connections made according to manufacturer’ s recommendations and to m eet applicable plumbing cod es.
Model 5600 & 5600 Econominder ® 7 Model 5600 Backwash Filter Installation and Start-up Procedures NOTE: Install the water softener with the inlet, outlet and drain connections made according to manufacturer’ s recommendations and to meet applicable pl umbing codes.
8 Model 5600 & 5600 Econominder ® Model 5600 Backwash Filter Installation and Start-up Procedures (Cont’d.) Cycle Times and Flow Diagrams 1. In Service position. See Figure 4, page 10 . 2. Preliminary Rinse position. — Same as Figure 4, page 10 with standard piston (white end plug) or filter piston (black end plug).
Model 5600 & 5600 Econominder ® 9 Model 5600 Econominder Installation and Start-up Procedures NOTE: Install the water softener with the inlet, outlet and drain connections made according to manufacturer’ s recommendations and to meet applicable pl umbing codes.
10 Model 5600 & 5600 Econominder ® Water Conditioner Flow Diagrams Service Position Pr eliminary Rinse Position Figur e 4 : Service Position Figur e 5 : Preliminary Rinse Position.
Model 5600 & 5600 Econominder ® 11 Water Conditioner Flow Diagrams (Cont’d.) Backwash Position Brine Position Figur e 6 : Backwash Position Figur e 7 : Brine Position.
12 Model 5600 & 5600 Econominder ® Water Conditioner Flow Diagrams (Cont’d.) Slow Rinse Position Second Backwash Position Figur e 8 : Slow Rinse Position Figur e 9 : Second Ba ckwash Position.
Model 5600 & 5600 Econominder ® 13 Water Conditioner Flow Diagrams (Cont’d.) Settling Rinse Position Brine T ank Fill Position Figure 10 : Settling Rinse Position Figur e 1 1 : Brine T ank Fill.
14 Model 5600 & 5600 Econominder ® Model 5600 Control Valve Drive Assembly Figur e 12 : Model 5600 Control V alve Drive Assembl y 1 29 27 20 16 15 19 22 5 1A 1A 13 14 37 39 12 38 34 21 7 8 6 9 2 .
Model 5600 & 5600 Econominder ® 15 Model 5600 Control Valve Drive Assembly ▲ Not used when a filter valve Item Number No. Req’d Part Number Description 1 1 14448-010 housing, with pin 1 14448.
16 Model 5600 & 5600 Econominder ® Model 5600 and 5600 Econominder Control Valve Drive Assembly Figure 13 : Model 5600 and 5600 Econominder Control V alve Drive Assembly 48 47 10 49 50 12 11 9 8 .
Model 5600 & 5600 Econominder ® 17 Model 5600 and 5600 Econominder Control Valve Drive Assembly * not used wi th meter controls ▲ used in backwash fi lter Item Number No. Req’d Part Number Description 1 2-4 13255 adapter clip (c lock or meter) 2 5 13242 seal 5 17772 silicone s eal 3 1 61400-12 valve body asse mbly , 1 ″ dist.
18 Model 5600 & 5600 Econominder ® Model 5600 Econominder Control Valve Drive Assembly Figur e 14 : Model 5600 Econominder Control V alve Drive Assembly 29 1 27 19 20 18 21 1A 13 12 42 14 44 43 3.
Model 5600 & 5600 Econominder ® 19 Model 5600 Econominder Control Valve Drive Assembly Item Number No. Req’d Part Number Description 11 14448-000 housing, with roll pin 1 14488-001 housing, wit.
20 Model 5600 & 5600 Econominder ® Bypass Valve Assembly, Plastic Figur e 15 : Bypass V alve Assembly , Plastic Item Number No. Req’d Part Number Description 9 2 13305 o-ring, 1 19 10 2 13255 c.
Model 5600 & 5600 Econominder ® 21 Bypass Valve Assembly, Brass Figur e 16 : Bypass V alve A ssembly , Brass Item Number No. Req’d Part Number Description 1 1 17290 bypass valve body , 3/4".
22 Model 5600 & 5600 Econominder ® Model 5600 Econominder Meter Assembly Figure 17 : Model 5600 Eco nominder Meter Assembly Item Number No. Req’d Part Number Description 1 4 12473 screw , meter.
Model 5600 & 5600 Econominder ® 23 Service Instructions Replace Time Brine V alve, Injectors and Scr een 1. Unplug electrical cord from outlet. 2.
24 Model 5600 & 5600 Econominder ® Service Instructions (Cont’d.) Replace Timer 1. Unplug electrical cord from outlet. 2. Turn off water supply t o conditioner: — If the conditioner i nstallation has a “three valve” bypass system, fi rst open the valve in the bypass l ine, then close the valves at the conditioner inlet and ou tlet.
Model 5600 & 5600 Econominder ® 25 Service Instructions (Cont’d.) Replace Piston Assembly 1. Unplug electrical cord from outlet. 2. Turn off water supply to conditioner: — If the conditioner .
26 Model 5600 & 5600 Econominder ® Service Instructions (Cont’d.) Replace Seals and Spacers 1. Unplug electrical cord from outlet. 2. Turn off water supply t o conditioner: — If the condition.
Model 5600 & 5600 Econominder ® 27 Service Instructions (Cont’d.) Replace Meter 1. Unplug electrical cord from outlet. 2. Turn off water supply to conditioner: — If the conditioner installation h as a “three valve” bypass sy st em, first open the valve in the bypass line, then close the valves at the conditioner inl et and outlet.
28 Model 5600 & 5600 Econominder ® Service Instructions (Cont’d.) Replace Meter Cover and/or Impeller 1. Unplug electrical cord from outlet. 2. Turn off water supply to conditioner: — If the .
Model 5600 & 5600 Econominder ® 29 Model 5600 and 5600 Econominder Troubleshooting PROBLEM CAUSE CORRECTION 1. Softener fails to regenerate. A. Electrical service to un it has been interrupted. A. Assure permanent electrical service (check fuse, plug, pull chain or switch).
30 Model 5600 & 5600 Econominder ® Model 5600 and 5600 Econominder Troubleshooting (Cont’d.) General Service Hints for Meter Contr ol PROBLEM CAUSE CORRECTION 9. Softener fails to draw brine. A. Draw line flow control is plugged. A. Clean drain line flow control.
Model 5600 & 5600 Econominder ® 31 Model 5600SF Troubleshooting PROBLEM CAUSE CORRECTION 1. Filter fails to backwash. A. Electrical service to unit has been interrupted. A. Assure permanent electrical service (check fuse, plug, pull chain or switch).
32 Model 5600 & 5600 Econominder ® Service Assemblies Part Number Description 60102-00 piston, softener 60102-10 piston, filter 60102-20 piston, low water 60125 seal kit 60084-XX injector 60032 b.
Model 5600 & 5600 Econominder ® 33 Notes:.
34 Model 5600 & 5600 Econominder ® Notes:.
.
P/N 40106 Rev . H 05/05.
デバイスPentair Model 5600 & 5600 Econominderの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pentair Model 5600 & 5600 Econominderをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPentair Model 5600 & 5600 Econominderの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pentair Model 5600 & 5600 Econominderの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pentair Model 5600 & 5600 Econominderで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pentair Model 5600 & 5600 Econominderを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPentair Model 5600 & 5600 Econominderの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pentair Model 5600 & 5600 Econominderに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPentair Model 5600 & 5600 Econominderデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。